Business > Industrial Devices > Automation Controls Top > Components & Devices > Relays / Couplers > Power Relays (Over 2A) > LZ-N Relays > Part Number > ALZN1B05W
*Photo may vary from actual product.
Product Number | ALZN1B05W |
Part Number | ALZN1B05W |
Product name | LZ-N Relays |
Features | EN60335-1 GWT compliant, 15.7 mm Low profile, 1 Form A/1 Form C 16 A, Power relays |
* | “ Product Number ” is ordering part number for non Japanese market. “ Part Number ” is ordering part number for Japanese market. |
---|
As of June 16, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | ALZN1B05W |
Part Number | ALZN1B05W |
Protective construction | Flux-resistant |
Operating function | Single side stable |
Terminal shape | PC board terminal |
Relay shape | Low profile type |
Coil insulation class | Class B insulation |
Standard packing Carton (pieces) |
100 |
Standard packing Case (pieces) |
500 |
Item | Specifications |
---|---|
Rated coil voltage | 5 V DC |
Operate voltage (at20°C) | Max. 70% V of rated coil voltage (Initial) |
Release voltage (at20°C) | Min. 10% V of rated coil voltage (Initial) |
Rated operating current [±10%] (at 20°C) | 80 mA |
Coil resistance [±10%] (at 20°C) | 63 Ω |
Rated operating power | 400 mW |
Max. allowable voltage | 120% V of rated coil voltage (at 85℃) |
Item | Specifications |
---|---|
Contact arrangement | 1 Form C |
Contact shape | Single |
Contact resistance (initial) | Max. 100 mΩ (by voltage drop 6 V DC 1 A) |
Contact material | AgSnO2 type |
Contact rating (resistive load) | 16 A 250 V AC |
Max. switching power (resistive load) | 4,000 VA |
Max. switching voltage | 440 V AC |
Max. switching current | 16 A |
Min. switching load (reference value) | 100 mA 5 V DC |
Insulation resistance (initial) | Min. 1,000 MΩ (at 500 V DC, Measured portion is the same as the case of dielectric strength.) |
Dielectric strength (initial) : Between open contacts | 1,000 Vrms for 1 min (detection current: 10 mA) |
Dielectric strength (initial) : Between contact and coil | 5,000 Vrms for 1 min (detection current: 10 mA) |
Surge withstand voltage (initial) : Between contact and coil | 10,000 V |
Operate time (initial) (at 20°C) | Max. 15 ms at rated coil voltage (without bounce) |
Release time (initial) (at 20°C) | Max. 5 ms at rated coil voltage (without bounce, without diode) |
Shock resistance (Functional) | 100 m/s2 (half-sine shock pulse: 11 ms, detection time: 10 μs) |
Shock resistance (Destructive) | 1,000 m/s2 (half-sine shock pulse: 6 ms) |
Vibration resistance (Functional) | 10 to 55 Hz (at double amplitude of 1.5 mm, Only the N.C. contact is 0.8 mm, detection time: 10 μs) |
Vibration resistance (Destructive) | 10 to 55 Hz (at double amplitude of 1.5 mm) |
Mechanical life | Min. 106 ope. (switching frequency: at 180 times/min) |
Conditions | Ambient temperature: -40 to +85℃ Humidity: 5 to 85% RH (Avoid icing and condensation) |
Unit weight | Approx. 11 g |
Item | Specifications |
---|---|
Resistive load | [at 20℃, switching frequency: at 20 times/min (ON : OFF = 1.5 s : 1.5 s)] N.O.: Min. 50x103 ope. 16 A 250 V AC N.C.: Min. 10x103 ope. 16 A 250 V AC |
Mark on products* |
* The "Mark on products" field shows the standards' certificate type marked to products. Note that not all certified products have a certificate mark affixed to them.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])