[Notification of CAD Data Download Issue]
We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Pressure Sensors / Flow Sensors > Pressure Sensors / Flow Sensors > Dual Display Digital Pressure Sensor [For Gas] DP-100L > Part Number > DP-101ZL3-M-P
*Photo may vary from actual product.
Product Number | DP-101ZL3-M-P |
Part Number | DP-101ZL3-M-P |
Product | Dual Display Digital Pressure Sensor [For Gas] |
Details | Discrete wire type |
Product name | Dual Display Digital Pressure Sensor [For Gas] DP-100L |
As of May 18, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | DP-101ZL3-M-P |
Part Number | DP-101ZL3-M-P |
Regulatory compliance and certification | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification |
Type of pressure | Gauge pressure |
Rated pressure range | -100.0 to +100.0 kPa |
Set pressure range | -101.0 to +101.0kPa |
Pressure withstandability | 500kPa |
Applicable fluid | Non-corrosive gas |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less |
Power consumption | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage) 360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) |
Communication output (C/Q):IO-Link communication | IO-Link Specification V1.1 (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Communication output (C/Q):Baud rate | COM3 (230.4 kbps) (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Communication output (C/Q):Process data | 4 byte (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Communication output (C/Q):Minimum cycle time | 1.0ms (Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO). |
Control output (DO) | PNP open-collector transistor •Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 2 V or less (at 50 mA source current) |
Control output (DO):Output operation | N.O./N.C. (selectable by key operation) |
Control output (DO):Output operationOutput modes | EASY mode / Hysteresis mode / Window comparator mode |
Control output (DO):Hysteresis | Minimum 1 digit (variable) |
Control output (DO):Repeatability | ±0.1 % F.S. (within ±2 digits) |
Control output (DO):Response time | 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation |
Control output (DO):Short-circuit protection | Incorporated |
Display | 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
Display:Displayable pressure range | -101.0 to +101.0 kPa |
Output indicator | Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2) Output operation indicator 2: Lights up when the control output is ON) |
Protection | IP40(IEC) |
Ambient temperature | -10 to +50℃ +14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃ +14 to +140 ℉ |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) |
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each |
Temperature characteristics | Within ±0.5 % F.S. (at +20℃ +68℉) |
Pressure port | M5 female thread |
Material | Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber |
Connecting method | Connector |
Cable length | Total length up to 20 m 65.617 ft (Condition of CE compliance less than 20 m 65.617 ft) is possible with 0.3 mm2, or more, cable. |
Weight | Net weight: 30 g approx., Gross weight: 125 g approx. |
Accessories | CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc. |
Remark | (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |
Product Number | CN-14A |
Part Number | CN-14A |
Product name | Connector |
Product Number | CN-14A-C1 |
Part Number | CN-14A-C1 |
Product name | Connector-attached cable |
Product Number | CN-14A-C2 |
Part Number | CN-14A-C2 |
Product name | Connector-attached cable |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)