ER-VW | Thin-type Ionizer ER-VW


Thin-type Ionizer ER-VW

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number ER-VW
Part Number ER-VW
Product Thin-type Ionizer
Details Spot type
Product name Thin-type Ionizer ER-VW

As of May 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number ER-VW
Part Number ER-VW
Charge removal time 1 sec. or less (plus or minus1,000 V to plus or minus100 V)
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ion balance plus or minus10 V or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
Ozone generation 0.05 ppm or less
(Note) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa.
Applicable fluid Air (dried clean air)
(Note) Dry clean air is air that has been processed through an air dryer (freezing point around –20 ℃ –4 ℉) and an air filter (mesh size around 0.01 microm 0.0004 mil).
Supplied air flow 60 liter/min. (ANR) or less
Air pressure range 0.05 to 0.5 MPa
Supply voltage 24 V DC plus or minus 10 %
Current consumption 120 mA or less
Discharge method High frequency AC method
Discharge output voltage 2,000 V approx.
Output [Check (CHECK) Error (ERROR) Discharge (DSC)] NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
(Note:"DSC" is an abbreviated name of "DISCHARGE".)
Output:Output operation Check output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normal
Error output (ERROR): OFF when abnormal discharge is detected, ON when operation is normal
Discharge output (DSC) (Note): ON when discharging, OFF when discharge halts
(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Output:Short-circuit protection Incorporated
Discharge halt input (DSC OFF) Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start)
(Note:"DSC" is an abbreviated name of "DISCHARGE".)
Reset input (RESET) In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR
Indicators:Power (POWER) Green LED (lights up when the power is ON)
Indicators:Discharge (DSC) Green LED (lights up when discharging)
(Note) ‘‘DSC’’ is an abbreviated name of ‘‘DISCHARGE’’.
Indicators:Air monitoring (AIR) Orange LED (lights up when no air is being supplied)
(Note) Discharge halts when lights up.
Indicators:Check (CHECK) Orange LED (lights up when the discharge needle is dirty or worn, etc.)
Indicators:Error (ERROR) Red LED (lights up when abnormal discharge is detected)
Ambient temperature 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ℉
Ambient humidity 35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH
I/O connector For power & input / output: 8-pin connector, For connection: 9-pin connector
Connectable units Maximum number of connectable units: 5 (Including this unit)
Enclosure earthing Capacitor earth
Material Enclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel. Discharge needle: Tungsten
Weight Net weight: 110 g approx., Gross weight: 180 g approx.
Accessories Connector attached cable: 1 pc. (length 0.5 m 1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc.

Return to top

Accessories (Option)

Discharge needle unit
Product Number ER-VWANT
Part Number ER-VWANT
Product Discharge needle unit
Product name Discharge needle unit
no_image
Product Number ER-VWAR80
Part Number ER-VWAR80
Product Joint kit
Details ER-VW Connector attached cable
Product name Joint kit
no_image
Product Number ER-VWCC2
Part Number ER-VWCC2
Product name Mating cable


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)