Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Pulse AC Method Area Ionizer ER-X > Part Number > ER-X001
*Photo may vary from actual product.
Product Number | ER-X001 |
Part Number | ER-X001 |
Product | Pulse AC Method Area Ionizer |
Details | Head |
Product name | Pulse AC Method Area Ionizer ER-X |
As of April 29, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | ER-X001 |
Part Number | ER-X001 |
Applicable regulations | CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), TÜV SÜD certification (USA, Canada) |
Effective charge removal width | 50 mm 1.969 in approx. |
Charge removal time | 0.3 sec. or less (Note 1), 0.5 sec. or less (Note 2) (Note 1: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and air supply 60 ℓ / min. (0.3 MPa)) . (Note 2: Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
Ion balance | ±30 V or less (Note 1:Typical value in condition of discharge distance 100 mm 3.937 in, center of the product, discharge frequency 30 Hz and no air supply.) (Note 2: Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature change is less than ±10 ℃, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.) |
Discharge method | Pulse AC method (Note:The discharge frequencies of 50 Hz, 20 Hz are accepted.) |
Discharge frequency | 50 Hz / 20 Hz |
Discharge output voltage | ±7,000 V approx. |
Ozone generation | 0.01 ppm or less (Note:Typical value in condition of discharge distance 50 mm 1.969 in, center of the product, discharge wavelength 50 Hz and no air supply.) |
Maximum air pressure | 0.5 MPa |
Applicable fluid | Air (dried clean air) (Note:The dried clean air is the air dried (dew point: equivalent of -20 ℃ -4 ℉) and filtered (mesh-size: equivalent of 0.01 μm) .) |
Operating altitude | 2,000 m 6561.68 ft or less (Note:Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.) |
Ambient temperature | 0 to +40 ℃ +32 to +104 ℉ (No dew condensation), Storage: -10 to +65℃ +14 to +149℉ |
Ambient humidity | 35 to 65 % RH, Storage: 35 to 85 % RH |
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each |
Shock resistance | 100 m/s2 acceleration (10 G approx.), in X, Y and Z directions three times each |
Enclosure earthing | Floating |
Material | Main unit enclosure: Stainless steal (SUS) Head mounting bracket: Stainless steal (SUS) Discharge needle: PFA, Tungsten |
Length of high-voltage cable | 1.2 m 3.937 ft |
Weight | Net weight : 370 g approx. |
Accessories | Head mounting bracket (installed at the time of factory shipment) |
Product Number | ER-XANT1 |
Part Number | ER-XANT1 |
Product name | Discharge needle unit |
Product Number | ER-XAPS |
Part Number | ER-XAPS |
Product name | AC adapter |
Product Number | ER-XCC2 |
Part Number | ER-XCC2 |
Product name | Power cable |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)