[Notification of CAD Data Download Issue]
We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Wire-Saving Systems > S-LINK V gateway controller for open network > Part Number > SL-VGU1-C
*Photo may vary from actual product.
Product Number | SL-VGU1-C |
Part Number | SL-VGU1-C |
Product | S-LINK V gateway controller for open network |
Details | For CC-Link |
Product name | S-LINK V gateway controller for open network |
As of May 18, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | SL-VGU1-C |
Part Number | SL-VGU1-C |
Supply voltage | 24V DC+10-5% |
Current consumption | 300mA or less (excluding error output load and power supply for driving I/O units) Note : The current consumption value shown here is the total of the maximum current (D-G line only) supplied to the S-LINK V I/O units and the current consumption of the S-LINK V gateway controller. |
Allowable through current | 7A Note : This product is not equipped with any short-circuit protective function. For this reason, select a power supply unit having short-circuit protective function (fuse, etc.). |
S-LINK V side : Transmission speed | A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps |
S-LINK V side : Refresh time | A mode: 0.29 to 10.32ms, B mode: 1.18 to 41.29ms, C mode: 4.70 to 165.15ms |
S-LINK V side : I/O points | Buffer memory assignment pattern 1: 128 inputs max., 128 outputs max. (Note 1) Buffer memory assignment pattern 2: 256 inputs max., 256 outputs max. (Note 2) Note 1 : In case of buffer memory assignment pattern 1, 112 channels are assigned to remote I/O (RX / RY) and the balance 16 channels are assigned to remote register (RWrm / RWwm). Note 2 : If buffer memory assignment pattern 2 is used, all the points will be assigned to the remote registers (RWrm / RWwm). |
S-LINK V side : Connected node No. | 256 nodes max. |
S-LINK V side : Transmission distance | A mode: 50m max., B mode: 200m max., C mode: 800m max. |
S-LINK V side : Total wiring length | A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less |
S-LINK V side : Transmission cable | Exclusive 4-core flat cable (0.5mm2) or Conductor cross-section area 0.3 to 2.0mm2 4-core VCTF cable (without shield) Note : The VCTF cable is the vinyl cabtyre cable that conforms to the requirements of JIS C 3306 "Polyvinyl chloride insulated flexible cords." |
S-LINK V side : I/O combination | I/O settable in units of 32 Nos. |
S-LINK V side : Error output | NPN open-collector transistor |
CC-Link side : Compatible network | CC-Link Ver.1.10 |
CC-Link side : Occupied station No. | 1 to 4 stations (varies with S-LINK V I/O control points.) |
CC-Link side : Transmission speed / Total extension | Transmission speed 10Mbps : Total extension 100m Transmission speed 5Mbps : Total extension 160m Transmission speed 2.5Mbps : Total extension 400m Transmission speed 625kbps : Total extension 900m Transmission speed 156kbps : Total extension 1,200m |
CC-Link side : Transmission cable | Specified cable (shielded twisted pair cable) |
CC-Link side : Remote unit claccification | Remote device unit |
Ambient temperature | 0 to +55℃ (No dew condensation), Storage: -20 to +70℃ |
Ambient humidity | 10 to 90% RH, Storage: 10 to 90% RH |
Material | Enclosure: ABS |
Net weight | Approx. 200g |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])