Configurator DL Detailed Version-Up Information

Version-up Information

Version-Up information (Ver.2.30 to Ver.2.40 Update: November 1, 2019)

The following points have been upgraded.

[Specification update]

  • "Mewtocol connection timeout" can be set in the range of 5 to 60 seconds. Old version is fixed 60 seconds.)

[Change specifications]

  • Changed "Sending cycle of collecting command" to "Waiting time of collecting command" in RS232C/485 setup dialog and added radio button to select "Time from send command" or "Time from receive command".

[Modify the below errors]

  • Cannot get the logging files through USB in some case.

Version-Up information (Ver.2.20 to Ver.2.30 Update: September 1, 2016)

The following points have been upgraded.

[Specification update]

  • Add ability to synchronize with the clock of KW1M-H.
  • Add the ability in the special DT register to count up every one second.
  • Add a new trigger that occurs when a register value is different from the previous one.

[Change specifications]

  • The same file name can not be registered.
  • When the subject of the data set is "main unit", device "Y" can not be selected.

Version-Up information (Ver.2.13 to Ver.2.20 Update: November 10, 2015)

The following points have been upgraded.

[Specificaton update]

  • Add 'Main unit' as an option for logging device.
  • Add ‘1,2,3,4’ as options for FTP retry interval.

[Change specifications]

  • When the usage is set to 'Computer link' at RS232C/R485 setup, it can't register communication I/F at COM1 and COM2.
  • Add message when you click OK without check at 'Create folder'.
  • Change the inital value
     --'Check battery voltage' : from No to Yes
  • Add setup to collect 64-bit data.
  • Available to set that it doesn't save the setup data history in system file.
  • Available to shift language without executing by administrator.
  • Available to download csv file via USB cable.

[Modify the below errors]

  • Scan time is not displayed correctly.
  • Contact status, ON and OFF, is not correct when you see the print preview and you print it.
  • It finishes when you input value with 16 digit or more as a setting value at data setting.

Version-Up information (Ver.2.12 to Ver.2.13 Update: June 6, 2014)

The following points have been upgraded.

[Specification update]

  • Half-width characters "<", ">" and " : " are available in an e-mail address.

Version-Up information (Ver.2.11 to Ver.2.12 Update: January 17, 2014)

The following points have been upgraded.

[Change specifications]

  • Support Microsoft (R) Windows 8.
  • File list function is improved.
    - Shift to upper folder by click button.
    - Delete and download folders.
  • Printing function is improved.
    - Print conversion factor and unit.

Version-Up information (Ver.2.10 to Ver.2.11 Update: August 6, 2012)

The following points have been upgraded.

[Modify the below errors]

  • When connecting by 1:1, no values are displayed for the Current value monitor.
  • The information of “Sending cycle of collecting command・Retry of collecting command” is not printed.
  • When MODBUS communication, the display is different from the selected device type with Logging device registration.

Version-Up Information(Ver.2.01 to Ver.2.10)

The following points have been upgraded.

[Add functions]

  • Retry function for FTP client.
  • Prohibited letter for logging file name, system history file name, trigger file name.
  • Prohibited letter for logging device name.

[Change specifications]

  • The initial values are changed.
    Logging command retry : not available -> available
    Use most recent data for the accumulation data : not available->Available

[Modify the below errors]

  • At MODBUS, ‘A to F’ can’t be input for logging device address input.

Version-Up Information(Ver.2.00 to Ver.2.01)

The following points have been upgraded.

[Modify the below errors]

  • A help function revised malfunction not to start.
  • By data setting, the permutation choice of data revised malfunction to have in spite of MEWTOCOL choice.
  • With print, the print indication of an SMTP server, the FTP server revised funny malfunction.

Version-Up Information(Ver.1.21 to Ver.2.00)

The following points have been upgraded.

[Add functions]

  • MODBUS (RTU) protocol is added.
  • Display of current value monitor is improved.
    - Communication error → "−" is displayed.
    - Display according to the condition set with logging device.
  • It is possible to reply with real-value for command from the upper.

[Change functions]

  • In case of using Easy-setup, "Make the destination folder name of logging file[CF]." is checked.

Version-Up Information(Ver.1.20 to Ver.1.21)

The following points have been upgraded.

[Add functions]

  • Method of data logging can be set.

[Change functions]

  • The initial value of the below items are changed.
    - Communication I/F COM1(RS232C) to COM2(RS485)
    - Transmission interval of collecting command 10ms to 100ms

[Modify the below errors]

  • When file is overwritten after timed out at logging file list, downloaded file is deleted.