Version-Up Information (Ver.2.62 to Ver.2.70)(January 17, 2014 update)
The following points have been upgraded.
[Change specs]
- Support Microsoft(R) Windows 8.
Version-Up Information (Ver.2.61 to Ver.2.62)(April 22, 2013 update)
The following points have been upgraded.
[Correct errors]
- When the graph of demand was displayed in group, the error that predicted demand unable to display was corrected.
Version-Up Information (Ver.2.60 to Ver.2.61)(December 4, 2012 update)
The following points have been upgraded.
[Correct errors]
- The problem that logging is not available when KW2G expantion units are set as station No.8 or 9.
Version-Up Information (Ver.2.50 to Ver.2.60)(November 1, 2012 update)
The following points have been upgraded.
[Add functions]
- Update to store the setting value of Eco-Power Meter.(Available only for USB communication on KW2G series.)
[Change specs]
Version-Up Information (Ver.2.40 to Ver.2.50)(October 1, 2012 update)
The following points have been upgraded.
[Correct errors]
- Add the number of selectable COM port (16 to 255)
Version-Up Information (Ver.2.30 to Ver.2.40)
The following points have been upgraded.
[Add functions]
- Graph for data of analog input and pulse input is available in graph function and csv graph function.
[Correct errors]
- The problem of the working when demand alarm or PF alarm is output was improved.
Version-Up Information (Ver.2.20 to Ver.2.30)
The following points have been upgraded.
[Add functions]
- Simple demand function of KW1M-H and KW8M with log function acceptable.
[Correct errors]
- The problem that time stamp was not updated for logging was improved.
- The problem that it doesn't work auto-save function was improved.
- The problem of display for PF with KW8M was improved.
- The problem of display for unit setup window was improved.
Version-Up Information (Ver.2.11 to Ver.2.20)
The following points have been upgraded.
[Add functions]
- KW2G expansion unit pulse input, analog input acceptable.
[Correct errors]
- The problem of display for logging was improved.
Version-Up Information (Ver.2.01 to Ver.2.11)
The following points have been upgraded.
[Add functions]
- KW2G acceptable.
- KW7M, KW8M new functions acceptable.
(1)Add items for terminal settings.
- Current alarm and stand-by alarm setting.
- Pre-scale setting (only KW8M)
(2)Counter display is changed. (only KW8M)
[Correct errors]
- The problem, that is not saved at csv graph display, was improved.
- The process of demand alarm was improved.
- The problem, logging KW2G data doesn't work correctly, was improved.
Version-Up Information (Ver.2.00 to Ver.2.01)
The following points have been upgraded.
- The Problem, that graph display doesn't work well, was improved.
Version-Up Information (Ver.1.52 to Ver.2.00)
The following points have been upgraded.
- You can change the display in English, Japanese, Chinese and Korean.
- The graph display functions are expanded.
Version-Up Information (Ver.1.51 to Ver.1.52)
The following points have been upgraded.
- In order to support AKW8115, CT type '1A' is added to 'Unit setup'.
Version-Up Information (Ver.1.42 to Ver.1.51)
The following points have been upgraded.
- KW1M, KW1M-H, KW1M-R acceptable
- The problem, that unit log read out function doesn't display correctly, was improved.
- The problem with the communication was improved.
Version-Up Information (Ver.1.41 to Ver.1.42)
The following points have been upgraded.
- You can monitor the item "CHG"and "CO2" at KW4M.
- You can make group with Ethernet by using KS1.
Version-Up Information (Ver.1.40 to Ver.1.41)
The following points have been upgraded.
- You can display a graph by using a logging file (CSV) of the below.
・ Saved by KW8M with log function type
・ Saved by Eco-Power Unit
・ Saved by KW Monitor
Version-Up Information (Ver.1.33 to Ver.1.40)
The following points have been upgraded.
- KW8M with log function type acceptable
Version-Up Information (Ver.1.32 to Ver.1.33)
The following points have been upgraded.
- Data collection cycle of second unit is added.
- In log window, you can change folder to save by auto save.
Version-Up Information (Ver.1.31 to Ver.1.32)
The following points have been upgraded.
- The problem, that graph function doesn't work well, was improved.
Version-Up Information (Ver.1.20 to Ver.1.31)
The following points have been upgraded.
- KW7M, KW8M Eco-Power METER acceptable
Version-Up Information (Ver.1.10 to Ver.1.20)
The following points have been upgraded.
- Ethernet communication acceptable
Version-Up Information (Ver.1.00 to Ver.1.10)
The following points have been upgraded.