[Notification of CAD Data Download Issue]   We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.

AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS GU SOP 1 Form A (SOP6-pin type)


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol Type of connection AQV212S AQV215S AQV217S AQV210S AQV214S AQV216S Remarks
Input LED forward current IF - 50 mA
LED reverse voltage VR - 5 V
Peak forward current IFP - 1 A f = 100 Hz,
Duty Ratio = 0.1%
Power dissipation Pin - 75 mW
Output Load voltage (peak AC) VL - 60 V 100 V 200 V 350 V 400 V 600 V
Continuous load current IL A 0.50 A 0.30 A 0.16 A 0.12 A 0.10 A 0.04 A A connection:
Peak AC, DC
B 0.65 A 0.40 A 0.20 A 0.13 A 0.11 A 0.05 A B, C connection: DC
C 0.80 A 0.56 A 0.28 A 0.15 A 0.12 A 0.06 A
Peak load current Ipeak - 1.5 A
0.90 A
0.48 A
0.3 A
0.3 A
0.12 A
A connection:
100 ms (1 shot),
VL = DC
Power dissipation Pout - 450 mW
Total power dissipation PT - 500 mW
I/O isolation voltage Viso - 1,500 Vrms
Ambient temperature (Operating) Topr - -40 to +85°C (Avoid icing and condensation)
Ambient temperature (Storage) Tstg - -40 to +100°C
Junction temperature Tj - 125°C

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol Type of connection AQV212S AQV215S AQV217S AQV210S AQV214S AQV216S Condition
Input LED operate current Typical IFon - 0.7 mA IL = Max.
Maximum 3 mA
LED turn off current Minimum IFoff - 0.4 mA IL = Max.
Typical 0.65 mA
LED dropout voltage Typical VF - 1.25 V (1.14 V at IF = 5 mA) IF = 50 mA
Maximum 1.5 V
Output On resistance Typical Ron A 0.83 Ω 2.3 Ω 11 Ω 23 Ω 30 Ω 70 Ω IF = 5 mA,
IL = Max.
Within 1 s
Maximum 2.5 Ω 4.0 Ω 15 Ω 35 Ω 50 Ω 120 Ω
Typical Ron B 0.44 Ω 1.15 Ω 5.5 Ω 11.5 Ω 22.5 Ω 55 Ω IF = 5 mA,
IL = Max.
Within 1 s
Maximum 1.25 Ω 2.0 Ω 7.5 Ω 17.5 Ω 25 Ω 100 Ω
Typical Ron C 0.25 Ω 0.6 Ω 2.8 Ω 6.0 Ω 11.3 Ω 28 Ω IF = 5 mA,
IL = Max.
Within 1 s
Maximum 0.63 Ω 1.0 Ω 3.8 Ω 8.8 Ω 12.5 Ω 50 Ω
Off state leakage current Maximum ILeak - 1 μA IF = 0 mA,
VL = Max.
Transfer characteristics Turn on time* Typical Ton - 0.65 ms 0.60 ms 0.25 ms 0.28 ms IF= 5 mA,
IL = Max.
Maximum 2.0 ms 1.0 ms 0.5 ms
Turn off time* Typical Toff - 0.08 ms 0.06 ms 0.05 ms 0.04 ms IF= 5 mA,
IL = Max.
Maximum 0.2 ms
I/O capacitance Typical Ciso - 0.8 pF f = 1 MHz,
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum Riso - 1,000 MΩ 500 V DC
*Turn on/Turn off time
Turn on/Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 5 30 mA
AQV212S Load voltage (Peak AC) VL - 48 V
Continuous load current (A connection) IL - 0.5 A
AQV215S Load voltage (Peak AC) VL - 80 V
Continuous load current (A connection) IL - 0.3 A
AQV217S Load voltage (Peak AC) VL - 160 V
Continuous load current (A connection) IL - 0.16 A
AQV210S Load voltage (Peak AC) VL - 280 V
Continuous load current (A connection) IL - 0.12 A
AQV214S Load voltage (Peak AC) VL - 320 V
Continuous load current (A connection) IL - 0.1 A
AQV216S Load voltage (Peak AC) VL - 480 V
Continuous load current (A connection) IL - 0.04 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)