Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Static Control Devices > Static Control Devices > Thin-type Ionizer ER-VW > Specifications
|
Type | Spot type | |
---|---|---|
Model No. | ER-VW | |
Charge removal time (±1,000 V → ±100 V) |
1 sec. or less (Note 2) | |
Ion balance | ±10 V or less (Note 2) | |
Ozone generation | 0.05 ppm or less (Note 3) | |
Applicable fluid | Air (dried clean air) (Note 4) | |
Supplied air flow | 60 l/min. (ANR) or less | |
Air pressure range | 0.05 to 0.5 MPa | |
Supply voltage | 24 V DC ± 10 % | |
Current consumption | 120 mA or less | |
Discharge method | High frequency AC method | |
Discharge output voltage | 2,000 V approx. | |
Output Check (CHECK) Error (ERROR) Discharge (DSC)(Note 5) |
NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1 V or less (at 50 mA sink current) |
|
Output operation | Check output (CHECK): ON when the discharge needle is dirty or worn, OFF when operation is normal Error output (ERROR): OFF when abnormal discharge is detected, ON when operation is normal Discharge output (DSC)(Note 5): ON when discharging, OFF when discharge halts |
|
Short-circuit protection | Incorporated | |
Discharge halt input (DSC OFF) (Note 5) |
Short-circuit to 0 V: Discharge halt, Open: Discharge allowed (operation start) | |
Reset input (RESET) | In the state that operation is stopped due to an error detection, open 0 V of the power supply from short-circuit state to cancel ERROR | |
Indicators | Power (POWER) | Green LED (lights up when the power is ON) |
Discharge (DSC)(Note 5) | Green LED (lights up when discharging) | |
Air monitoring (AIR) (Note 6) | Orange LED (lights up when no air is being supplied) | |
Check (CHECK) | Orange LED (lights up when the discharge needle is dirty or worn, etc.) | |
Error (ERROR) | Red LED (lights up when abnormal discharge is detected) | |
Ambient temperature | 0 to +55 ℃ +32 to +131 ℉ (No dew condensation allowed), Storage: -10 to +65 ℃ +14 to +149 ℉ |
|
Ambient humidity | 35 to 65 % RH (No dew condensation allowed), Storage: 35 to 65 % RH | |
I/O connector | For power & input / output: 8-pin connector, For connection: 9-pin connector | |
Connectable units | Maximum number of connectable units: 5 (Including this unit) | |
Enclosure earthing | Capacitor earth | |
Material | Enclosure: ABS (Nickel plated), Nozzle mount, Screw mount, Nozzle: Stainless steel, Discharge needle: Tungsten | |
Weight | Net weight: 110 g approx., Gross weight: 180 g approx. | |
Accessories | Connector attached cable: 1 pc. (length 0.5 m 1.640 ft), End connector (9-pin): 1 pc., Lead wire for connecting F.G.: 1 pc. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) A typical sample applied with a supply voltage of 24 V, a distance of 100 mm 3.937 in from the front surface of the air flow outlet and a pressure of 0.25 MPa. (Measured on a sample left in the atmosphere at a relative humidity of 65 % RH or less for 24 hours or more.)
3) A typical sample applied with a supply voltage of 24 V, a distance of 300 mm 11.811 in from the front surface of the air flow outlet and a pressure of 0.25 MPa.
4) Dried clean air is the air passing through air dryer (dew point –20 ℃ –4 ℉ approx.) and air filter (mesh size 0.01 μm 0.0004 mil approx.)
5) "DSC" is an abbreviated name of "DISCHARGE".
6) Discharge halts when lights up.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)