AUTOMATION
CONTROLS

Search
Discontinued
Products



PhotoMOS HE 1 Form A High Capacity


RATING

■ Absolute maximum ratings (Ambient temperature: 25°C)

Item Symbol Type of connection AQV252G3 (A) AQV255G3 (A) Remarks
Input LED forward current
IF
- 50 mA  
LED reverse voltage
VR
- 5 V  
Peak forward current
IFP
- 1 A f=100 Hz
Duty Ratio=0.1%
Power dissipation
Pin
- 75 mW  
Output Load voltage
(peak AC)
VL
- 60 V 100 V  
Continuous load current
IL
A 3.5 A 2.4 A A connection:
Peak AC, DC
B 5.0 A 3.2 A B, C connection: DC
C 7.0 A 4.8 A
Peak load current
Ipeak
- 10 A 7.0 A 100 ms (1 shot), VL=DC
at A connection
Power dissipation
Pout
- 600 mW  
Total power dissipation
PT
- 650 mW  
I/O isolation voltage
Viso
- 1,500 Vrms  
Ambient temperature
(Operating)
Topr
- -40 to +85°C (Avoid icing and condensation)
Ambient temperature
(Storage)
Tstg
- -40 to +100°C  
Junction temperature
Tj
- 125°C  

■ Electrical characteristics (Ambient temperature: 25°C)

Item Symbol Type of connection AQV252G3(A) AQV255G3(A) Condition
Input LED operate current Typical
IFon
- 0.5 mA IL = 100 mA
Maximum 3 mA
LED turn off current Minimum
IFoff
- 0.2 mA IL = 100 mA
Typical 0.4 mA
LED dropout voltage Typical
VF
- 1.32 V (1.14 V at IF = 5 mA) IF = 50 mA
Maximum 1.5 V
Output On resistance Typical
Ron
A 0.033 Ω 0.07 Ω A connection
IF = 5 mA
IL = Max.
Within 1 s
Maximum 0.06 Ω 0.12 Ω
Typical
Ron
B 0.017 Ω 0.035 Ω B connection
IF = 5 mA
IL = Max.
Within 1 s
Maximum 0.04 Ω 0.07 Ω
Typical
Ron
C 0.0095 Ω 0.02 Ω C connection
IF = 5 mA
IL = Max.
Within 1 s
Maximum 0.02 Ω 0.04 Ω
Off state leakage current Maximum
ILeak
- 1 μA IF = 0 mA
VL = Max.
Transfer characteristics Turn on time* Typical
Ton
- 1.8 ms IF = 5 mA
IL = 100 mA
VL = 10 V
Maximum 5 ms
Turn off time* Typical
Toff
- 0.15 ms IF = 5 mA
IL = 100 mA
VL = 10 V
Maximum 0.5 ms
I/O capacitance Typical
Ciso
- 0.8 pF f = 1 MHz
VB = 0 V
Maximum 1.5 pF
Initial I/O isolation resistance Minimum
Riso
- 1,000 MΩ 500 V DC
Max. operating frequency Maximum
-
- 2.5 cps IF = 5 mA
duty = 50%
IL = Max.
VL = Max.
*Turn on/Turn off time
Turn on / Turn off time

■ Recommended operating conditions (Ambient temperature: 25°C)

Please use under recommended operating conditions to obtain expected characteristics.

Item Symbol Min. Max. Unit
LED current IF 5 30 mA
AQV252G3(A) Load voltage (Peak AC) VL - 48 V
Continuous load current (A connection) IL - 3.3 A
AQV255G3(A) Load voltage (Peak AC) VL - 80 V
Continuous load current (A connection) IL - 2.4 A

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region







BY PHONE

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)