Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Ultra-slim Light Curtain [Type 2 PLc SIL1] SF2C > Cautions For Use
・ | This website is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. |
---|---|
・ | Both emitter and receiver are combined adjusted on factory setting, please apply both emitter and receiver with the same serial No. The serial No. is indicated on the plates of both emitter and receiver. (Indicated under the model No.) |
|
|
Common for emitter and receiver |
Description | Function |
---|---|
Large multi-purpose indicator (Orange) |
Lights up when input for the large multi-purpose indicator is valid. Turns OFF when input for the large multi-purpose indicator is invalid. |
Frequency setting indicator (Orange) [FREQ] |
Turns OFF when Frequency 1 is set. Lights up when Frequency 2 is set. |
Fault indicator (Yellow) [FAULT] |
Turns OFF during normal operation. Lights up or blinks when fault occurs in the device. |
Emitter |
Description | Function |
---|---|
Operation indicator (Green) [POWER] |
Lights up when device operation is as follows. Turns OFF when test input is valid. |
Test indicator (Red) [TEST] |
Lights up when test input is valid. Turns OFF when test input is invalid. |
Receiver |
Description | Function |
---|---|
OSSD indicator (Red / green) [OSSD] |
When control output (OSSD) is OFF: lights up in red When control output (OSSD) is ON: lights up in green |
Unstable light reception indicator (Orange) [STB] |
Turns OFF when stable light is received (the percentage of light received is more than 150%). [Control output (OSSD) ON] Lights up when unstable light is received (the percentage of light received is between 100% and 150%). [Control output (OSSD) ON] Turns OFF when light is blocked (the percentage of light received is less than 100%). (Note 1) [Control output (OSSD) OFF] |
Notes: 1) | Besides, ‘when light is blocked’ refers to the status that there exists any object blocking light in the sensing area. |
---|---|
2) | The description given in [ ] is marked on the device. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]