Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Ultra-slim Light Curtain [Type 2 PLc SIL1] SF2C > Specifications
Type | PNP output type | NPN output type | |
---|---|---|---|
Model No. | SF2C-H□-P | SF2C-H□-N | |
Applicable standards |
International standard |
IEC 61496-1/2 (Type 2), ISO 13849-1:2015 (Category 4, PLc), IEC 61508-1 to 3 (SIL1) | |
Japan | JIS B 9704-1/2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 1 to 3 (SIL1) | ||
Europe (Note 2) |
EN 61496-1 (Type 2), EN ISO 13849-1:2015 (Category 4, PLc), EN 61508-1 to 3 (SIL1), EN 55011, EN 50178, EN 61000-6-2 |
||
North America (Note 3) |
ANSI/UL 61496-1/2 (Type 2), ANSI/UL 508, CAN/CSA 61496-1/2 (Type 2), CAN/CSA C22.2 No.14, ANSI/RIA 15.06 |
||
Regulatory compliance | CE Marking (Machinery Directive, EMC Directive, RoHS Directive),UKCA Marking [Supply of Machinery (Safety) Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification | ||
Operating range | 0.1 to 3 m 0.328 to 9.843 ft | ||
Beam pitch | 20 mm 0.787 in | ||
Min. sensing object | ø25 mm ø0.984 in opaque object | ||
Effective aperture angle | ±5° or less [for an operating range exceeding 3 m 9.843 ft(conforming to IEC 61496-2 / ANSI/UL 61496-2)] | ||
Supply voltage | 24 V DC ± 20 % Ripple P-P 10 % or less | ||
Control output(OSSD) | ・ Maximum source current: 200mA ・ Applied voltage: same as supply voltage (between the control output and +V) ・ Residual voltage: 2.5V or less (source current 200mA, when using 10m 32.808 ft length cable) ・ Leakage current: 200μA or less (power supply OFF condition) ・ Maximum load capacity: 2.2μF (No load to maximum sink current) ・ Load wiring resistance: 3Ω or less |
・ Maximum sink current: 200mA ・ Applied voltage: same as supply voltage (between the control output and -0V) ・ Residual voltage: 2.5V or less (sink current 200mA, when using 10m 32.808 ft length cable) ・ Leakage current: 200μA or less (power supply OFF condition) ・ Maximum load capacity: 2.2μF (No load to maximum sink current) ・ Load wiring resistance: 3Ω or less |
|
Operation mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
||
Protection circuit | Incorporated | ||
Response time | OFF response: 20 ms or less, ON response: 80 to 100 ms | ||
Lockout output(SSD) | ・ Maximum source current: 60mA ・ Applied voltage: same as supply voltage (between the lockout output and +V) ・ Residual voltage: 2.5V or less (source current 60mA, when using 10m 32.808 ft length cable) ・ Leakage current: 200μA or less (power supply OFF condition) ・ Maximum load capacity: 2.2μF (No load to maximum source current) ・ Load wiring resistance: 3Ω or less |
・ Maximum sink current: 60mA ・ Applied voltage: same as supply voltage (between the lockout output and -0V) ・ Residual voltage: 2.5V or less (sink current 60mA, when using 10m 32.808 ft length cable) ・ Leakage current: 200μA or less (including power supply OFF condition) ・ Maximum load capacity: 2.2μF (No load to maximum sink current) ・ Load wiring resistance: 3Ω or less |
|
Operation mode | ON during normal operation, OFF during lockout(Note 4) | ||
Protection circuit | Incorporated | ||
Interference prevention function | Incorporated | ||
Test input function | Incorporated | ||
Large display unit function | Incorporated | ||
Pollution degree | 3 | ||
Operating altitude | 2,000 m 6561.680 ft or less(Note 5) | ||
Degree of protection | IP65, IP67(IEC) | ||
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉(No dew condensation or icing allowed), Storage: –25 to +60 ℃ –13 to +140 ℉ |
||
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH | ||
Ambient illuminance | Incandescent light: 5,000 ℓx or less at the light-receiving face | ||
Dielectric strength voltage | 1,000 V AC for one min. between all supply terminals connected together and enclosure | ||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure | ||
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | ||
Shock resistance | 300 m/s2 984.252 ft/s2 acceleration(30 G approx.) in X, Y and Z directions three times each | ||
Emitting element | Infrared LED(Peak emission wavelength: 850 nm 0.034 mil) | ||
Cable | 0.16 mm2 5-core heat-resistant PVC cable, 3 m 9.842 ft long | ||
Cable extension | Extension up to 50m 164.042 ft is possible for both emitter and receiver, with 0.3mm2 or more, cable | ||
Material | Enclosure: Polycarbonate alloy, Sensing surface: Polycarbonate alloy, MS-SFC-1(Standard mounting bracket) : Stainless steel(SUS) |
||
Accessories | MS-SFC-1(Standard mounting bracket): 1 set, SF4C-TR25(Test rod): 1 No. |
Note:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉. |
---|---|
2) | Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
3) | With regards to the standards in the US/Canada, a Notified Body, TÜV SÜD, has certified the CTÜVUS mark. |
4) | If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
5) | Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) | ||||
---|---|---|---|---|---|
PNP output type | SF2C-H8-P | SF2C-H12-P | SF2C-H16-P | SF2C-H20-P | |
NPN output type | SF2C-H8-N | SF2C-H12-N | SF2C-H16-N | SF2C-H20-N | |
No. of beam channels | 8 | 12 | 16 | 20 | |
Protective height | 160 mm 6.299 in | 240 mm 9.449 in | 320 mm 12.598 in | 400 mm 15.748 in | |
Current consumption |
Large multi- purpose indicator lights off |
Emitter: 25 mA or less Receiver: 25 mA or less |
Emitter: 30 mA or less Receiver: 30 mA or less |
Emitter: 35 mA or less Receiver: 35 mA or less |
|
Large multi- purpose indicator lights up |
Emitter: 35 mA or less Receiver: 30 mA or less |
Emitter: 35 mA or less Receiver: 35 mA or less |
Emitter: 40 mA or less Receiver: 35 mA or less |
Emitter: 40 mA or less Receiver: 40 mA or less |
|
PFHD (Note) |
PNP output type | 3.60×10-9 | 3.66×10-9 | 3.73×10-9 | 3.79×10-9 |
NPN output type | 3.74×10-9 | 3.80×10-9 | 3.86×10-9 | 3.93×10-9 | |
MTTFD (Note) | 100 years or more | ||||
Net weight (Total of emitter and receiver) |
280 g approx. | 340 g approx. | 400 g approx. | 460 g approx. |
Note: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years) |
---|
Type | Min. sensing object ø25 mm ø0.984 in (20 mm 0.787 in beam pitch) | |||
---|---|---|---|---|
PNP output type | SF2C-H24-P | SF2C-H28-P | SF2C-H32-P | |
NPN output type | SF2C-H24-N | SF2C-H28-N | SF2C-H32-N | |
No. of beam channels | 24 | 28 | 32 | |
Protective height | 480 mm 18.898 in | 560 mm 22.047 in | 640 mm 25.197 in | |
Current consumption |
Large multi- purpose indicator lights off |
Emitter: 35 mA or less Receiver: 35 mA or less |
||
Large multi- purpose indicator lights up |
Emitter: 45 mA or less Receiver: 40 mA or less |
Emitter: 45 mA or less Receiver: 45 mA or less |
Emitter: 50 mA or less Receiver: 45 mA or less |
|
PFHD (Note) |
PNP output type | 3.85×10-9 | 3.92×10-9 | 3.98×10-9 |
NPN output type | 3.99×10-9 | 4.05×10-9 | 4.12×10-9 | |
MTTFD (Note) | 100 years or more | |||
Net weight (Total of emitter and receiver) |
520 g approx. | 580 g approx. | 640 g approx. |
Note: | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. PFHD: Probability of dangerous failure per hour, MTTFD: Mean time to dangerous failure (in years) |
---|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)