【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Key selector switch SG-D1(Discontinued Products) > Specifications
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
Model No. | Position | Contact configuration |
Contact block | Operation position | Key removal Mounting position |
||
---|---|---|---|---|---|---|---|
Mounting position (Note) |
Contact | 1 | 2 | ||||
SG-D1-2A11 | 1NO/1NC (11) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
SG-D1-2A22 | 2NO/2NC (22) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
[3] | NO | ● | |||||
[4] | NC | ● | |||||
SG-D1-2B11 | 1NO/1NC (11) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
SG-D1-2B22 | 2NO/2NC (22) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
[3] | NO | ● | |||||
[4] | NC | ● | |||||
SG-D1-2C11 | 1NO/1NC (11) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
SG-D1-2C22 | 2NO/2NC (22) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
[3] | NO | ● | |||||
[4] | NC | ● |
Note: | Contact blocks are attached as shown below: |
---|
Designation | Key selector switch | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Series | SG-D1 series | |||||||||
Applicable standards |
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | |||||||||
Operating condition | Ambient temperature |
-25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage: -40 to +80 ℃ -40 to +176 ℉ |
||||||||
Ambient humidity | 45 to 85 % RH | |||||||||
Pollution degree | 3 | |||||||||
Altitude | 2,000 m 6,561.68 ft max. | |||||||||
Impulse withstand voltage (Uimp) |
4 kV | |||||||||
Rated insulation voltage (Ui) |
600 V | |||||||||
Thermal current (Ith) | 10 A | |||||||||
Rated operational voltage (Ue) / Rated operational current (Ie) |
Ue | |||||||||
24V | 48V | 50V | 110V | 220V | 440V | |||||
Ie | AC | Resistive load (AC-12) |
10A | - | 10A | 10A | 6A | 2A | ||
Inductive load (AC-15) (A600)) |
10A | - | 7A | 5A | 3A | 1A | ||||
DC | Resistive load (DC-12) |
8A | 4A | - | 2.2A | 1.1A | - | |||
Inductive load (DC-13) (P600) |
4A | 2A | - | 1.1A | 0.6A | - | ||||
Contact resistance |
50 mΩ max. (initial value) | |||||||||
Insulation resistance |
100 MΩ min. (500 V DC megger) | |||||||||
Electric shock protection class |
Class II(IEC 61140) | |||||||||
Overvoltage category |
II(IEC 60664-1) | |||||||||
Protection | Front of the panel: IP65 | |||||||||
Shock resistance | Malfunction: 100 m/s2, Destruction: 1,000m/s2 | |||||||||
Vibration resistance |
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in |
|||||||||
B10d | 100,000 (ISO 13849-1 Annex C Table C.1) |
|||||||||
Mechanical durability |
100,000 operations min. | |||||||||
Electrical durability |
100,000 operations min. (1,200 operations/hour) | |||||||||
Material | Actuator: PA6, Contact block: PA66 | |||||||||
Connecting method |
Terminal screw (M3.5 philips & flathead ) | |||||||||
Applicable wire size |
Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. |
|||||||||
Tightening torque of the terminal screws |
1.0 to 1.3 N・m | |||||||||
Tightening torque of the locking ring |
2.0 N・m | |||||||||
Selector behavior | 2 positions | |||||||||
Minimum direct opening operating angle |
90° | |||||||||
Minimum direct opening torque |
0.4 N・m | |||||||||
Maximum operation angle |
90° | |||||||||
Weight | SG-D1-2□11: Approx. 75 g, SG-D1-2□22:Approx. 95 g | |||||||||
Accessories | Key: 2pcs., Lever lock: 1 pc. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)