[Notification of CAD Data Download Issue]
We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.
企業專屬首頁 > 電子元件/工業用機器 > 制御機器首頁 > EX-F71-C5
※產品實際尺寸以實物為準
品名 | EX-F71-C5 |
型號 | EX-F71-C5 |
產品 | Leak Detection Sensor |
詳細 | General purpose |
產品名稱 | 滲漏檢測感測器[放大器內藏] EX-F70/EX-F60 |
項目 | 內容 |
---|---|
品名 | EX-F71-C5 |
型號 | EX-F71-C5 |
Sensing object | Water, Fluorinert™ Note:Highly viscous liquid may not be detected stably. Note:Fluorinert is the world wide trademark of 3M. |
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
Current consumption | 10 mA or less(PNP output type: 15 mA or less) |
Output | NPN open-collector transistor - Maximum sink current: 50 mA - Applied voltage: 30 V DC or less (between output and 0 V) - Residual voltage: 1.0 V or less (at 50 mA sink current), 0.4 V or less (at 16 mA sink current) |
Output:Output operation | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF |
Output:Short-circuit protection | Incorporated |
Response time | 50 ms or less |
FAULT indicator | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) |
NORMAL indicator | Green LED (lights up when the sensor is mounted properly) |
Protection | IP67 (IEC) |
Ambient temperature | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 1,000 ℓx or less at the light-receiving face |
Emitting element | Infrared LED (non-modulated) |
Material | Enclosure: Polypropylene |
Cable extension | Extension up to total 50 m |
Accessory | MS-EX-F7-1(SUS mounting bracket): 1 pc. Note : The mounting bracket for EX-F71(-PN) is not interchangeable with that of EX-F72(-PN) due to the different sensitivity settings of each sensor. |