Item Specifications
Input voltage AC type : 12, 24, 100/110, 200/220V
DC type : 12, 24, 100/110, 200/220V
No. of digit 6 digits
Counting mechanism 1/2 count while power is on, 1/2 count while at rest
Resetting method Manual reset push-button, electromagnetic reset with manual push-button
Initial insulation resistance Min. 100MΩ : Between live and dead metal parts
Initial eith stand voltage 1,500Vrms for 1min. : Between live and dead metal parts
Shock resistance Functional Min. 49m/s2 {5G}
Destructive Min. 735m/s2 {75G}
Vibration resistance Functional 45Hz, (1 cycle/min), double amplitude : 1.5 mm
Destructive 10 to 55Hz, (1 cycle/min), double amplitude : 0.75 mm
Ambient temperature/humidity -10℃ to +40℃ +14℉ to 104℉ / Max. 90%RH

INPUT CURRENT CONSUMPTION

Input voltage 25Hz(cps)
(AC Input) type
12V AC Approx. 180mA
24V AC Approx. 72mA
100/110V AC Approx. 18/19mA
200/220V AC Approx. 8.8/9.5mA
Input voltage 50Hz(cps) 100Hz(cps)
Counting coil Reset coil Counting coil Reset coil
12V DC 258mA 732mA 732mA 732mA
24V DC 108mA 516mA 369mA 516mA
100/110V DC 26/28mA 124/137mA 74/82mA 124/137mA
200/220V DC 12/13mA 51/57mA 34/37mA 51/57mA

Return to top

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)