Rating/ Performance

Rated operating voltage 100V AC, 200V AC, 110V AC, 115 to 120V AC, 220V AC, 240V AC
Allowable operating voltage range 85 to 115% of rated operating voltage
Rated frequency 50 Hz, 60 Hz (other model)
Counting range 0 to 99999.9 hours (TH13 series)
0 to 9999.9 hours (TH23 series)
Minimum time display 0.1 hours (6 min)
Rated power consumption Approx. 1.5 W
Insulation resistance
(Initial value)
Min. 100 MΩ, Between live and dead metal parts (At 500V DC)
Breakdown voltage
(Initial value)
2,000 Vrms, Between live and dead metal parts
Max. temperature rise 55℃ 131℉
Vibration resistance Functional 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes)
Shock resistance Functional Min. 98 m/s2 {10 G} (4 times on 3 axes)
Destructive Min. 980 m/s2 {100 G} (5 times on 3 axes)
Ambient temperature –10 to +50℃ +14 to 122℉
Ambient humidity Max. 85% RH (non-condensing)
Weight 135 g 4.76 oz (TH13 series)
130 g 4.59 oz (TH23 series)