TH50 Minutes Indicator Hour Meters (Discontinued Products)
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
September 30, 2016 |
|
|
Rating/ Performance
Rated operating voltage |
12 V AC, 24 V AC, 48 V AC, 100 V AC, 110 V AC, 115 to 120 V AC, 200 V AC, 220 V AC, 240 V AC |
Allowable operating voltage range |
85 to 115% of rated operating voltage |
Rated frequency |
50/60 Hz (selectable by switch) |
Counting range |
0 to 9999.9 min |
Minimum time display |
0.1 min (6 sec) |
Rated power consumption |
Approx. 1.5 W |
Insulation resistance (Initial value) |
Min. 100 MΩ, Between live and dead metal parts (At 500 V DC) |
Breakdown voltage (Initial value) |
2,000 Vrms, Between live and dead metal parts |
Max. temperature rise |
55℃ 131℉ |
Vibration resistance |
Functional |
10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) |
Shock resistance |
Functional |
Min. 98 m/s2 {10 G} (4 times on 3 axes) |
Destructive |
Min. 980 m/s2 {100 G} (5 times on 3 axes) |
Ambient temperature |
–10 to +50℃ +14 to +122℉ |
Ambient humidity |
Max. 85% RH (non-condensing) |
Weight |
150 g 5.29 oz |
Return to top
Return to top