Rated operating voltage | 12 V AC, 24 V AC, 48 V AC, 100 V AC, 110 V AC, 115 to 120 V AC, 200 V AC, 220 V AC, 240 V AC |
|
---|---|---|
Allowable operating voltage range |
85 to 115% of rated operating voltage | |
Rated frequency | 50/60 Hz (selectable by switch) | |
Counting range | 0 to 99999.9 hours (TH63 series) 0 to 9999.9 hours (TH64 series) |
|
Minimum time display | 0.1 hours (6 min) | |
Rated power consumption | Approx. 1.5 W | |
Insulation resistance (Initial value) |
Min. 100 MΩ, Between live and dead metal parts (At 500 V DC) | |
Breakdown voltage (Initial value) |
2,000 Vrms, Between live and dead metal parts | |
Max. temperature rise | 55℃ 131℉ | |
Vibration resistance | Functional | 10 to 55 Hz: 1 cycle/min double amplitude of 0.5 mm (10 min on 3 axes) |
Shock resistance | Functional | Min 98 m/s2 {10 G} (4 times on 3 axes) |
Destructive | Min 980 m/s2 {100 G} (5 times on 3 axes) | |
Ambient temperature | –10 to +50℃ +14 to +122℉ | |
Ambient humidity | Max. 85% RH (non-condensing) | |
Weight | Approx. 80 g 2.82 oz |
|