Type TH833C TH834C
Rating Rated voltage 12 V DC 24 V DC
Usage voltage range 10.2 to 15.6 V DC 20.4 to 31.2 V DC
Measurement time 0 to 9999.9 hours
Min. measurement time 0.1 hour (6 min.)
Power consumption Approx. 1.5 W (With rated voltage applied at 25℃ 77℉)
Electrical
characteristics
Insulation resistance
(initial)
Min. 100 MΩ between charged and uncharged parts (measured at 500 V DC)
Breakdown voltage
(initial)
Between charged and uncharged parts: 2,000 V AC for 1 minute.
Temperature rise Max. 55℃ 131℉ (measured at rated voltage and resistance law)
Mechanical
characteristics
Functional vibration resistance 10 to 55 Hz (1 cycle/min.)
Single amplitude: 0.35 mm (10 min. ON 3 axes)
Functional shock resistance Min. 98 m/s2 (4 times ON 3 axes)
Destructive vibration resistance Min. 980 m/s2 (5 times ON 3 axes)
Usage conditions Operation temperature –20℃ to +60℃ –4℉ to +140℉ (Without due and frost)
Ambient humidity 35 to 85% RH (relative humidity) (non-condensing)
Power supply ripple Approx. 48% or less (single phase, all-wave rectification)
Protective construction IP66 (front panel with a rubber gasket)

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)