Rating

Rated control voltage 12/24V DC (at 12V DC: approx. 6 mA, 24V DC: approx. 11 mA)
Response time Max. 10ms
Output current Max. 150 mA
Note :When used as a direct load, any DC type relay may be applied.

Characteristics

Allowable operating voltage 10 to 30V DC (Ripple factor: max. 10%)
Adjustable sensitivity 20 to 50pF
Vibration resistance Functional 10 to 55 Hz, double amplitude of 0.3mm .012inch
Destructive 16.7 Hz, double amplitude of 4mm .157inch
Shock resistance Min. 980m/s2 {100G}
Initial insulation resistance
(At 500V DC)
Min. 100MΩ; Between each terminal, antenna and ground
Breakdown voltage 1,500V AC for 1 min Between each terminal, antenna and ground
Expected life
(min. operations)
107 (at 500 cps, 150mA resistive load) (Antenna portion of wire spring type: operating speed 120 cpm at O.T.=20mm)
Power source ripple factor Max. 10%
Ambient temperature/humidity –20 to +60℃ –4 to +140℉/Max. 95%R.H. (at 20℃ 68℉)
Max. operating speed 50 cps (Antenna portion of wire spring type: 120 cpm at O.T.=20mm)
Detected object Conductor

Protective characteristics

Protective
construction
VL-T Mini touch
limit switches
IEC
IP60
IP64

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)