High Speed・High Accuracy Eddy Current Type Digital Displacement Sensor GP-X

Specifications

Sensor heads

Type Non-threaded type Threaded type
For 0.8 mm 0.031 in sensing For 1 mm 0.039 in sensing For 2 mm 0.079 in sensing For 2 mm 0.079 in sensing For 5 mm 0.197 in sensing For 10 mm 0.394 in sensing
Model No. GP-X3SE GP-X5SE GP-X8S GP-X10M GP-X12ML GP-X22KL
Applicable regulations CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Sensing range (Note 2) 0 to 0.8 mm
0 to 0.031 in
0 to 1 mm
0 to 0.039 in
0 to 2 mm
0 to 0.079 in
0 to 2 mm
0 to 0.079 in
0 to 5 mm
0 to 0.197 in
0 to 10 mm
0 to 0.394 in
Standard sensing object Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 x 60 x t 1 mm 2.362 x 2.362 x t 0.039 in
Temperature characteristics (Note 3) 0.07 % F.S./℃ or less
Pollution degree 3 (Industrial environment)
Protection IP67 (IEC), IP67G (Note 6)
Ambient temperature -10 to +55 ℃ +14 to +131 ℉, Storage: -20 to +70 ℃ -4 to +158 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Voltage withstandability 250 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions five times each
Material Enclosure Stainless steel (SUS303) Brass (Nickel plated)
Cable protector - PP
Sensing part ABS PAR ABS PA
Cable High frequency coaxial cable with connector, 3 m 9.843 ft long (Note 4)
Cable extension Extension up to total 10 m 32.808 ft is possible with the optional cable.
Net Weight (Note 5) 40 g approx. 40 g approx. 40 g approx. 50 g approx. 45 g approx. 80 g approx.
Accessories - Nut: 2 pcs., Toothed lock washer: 1 pc.

Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
Note 2 :The sensing range is specified for the standard sensing object.
Note 3 :This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.
Note 4 :For the flexible cable type, please contact our office.
Note 5 :The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.
Note 6 :If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil. Please check the resistivity of the sensor against the cutting oil you are using beforehand.

Controllers

Type NPN output PNP output
Set model No. GP-XC□ GP-XC□-P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive) (Note 6), UKCA Marking (EMC Regulations, RoHS Regulations) (Note 6), Korea's radio regulations (Radio Wave Act KC)
Supply voltage 24 V DC ± 10 % Ripple P-P 10 % or less
Current consumption 150 mA or less
Resolution (Note 2) GP-XC3SE / GP-XC5SE: 0.04 % F.S. (64 times average processing)
GP-XC8S / GP-XC10M / GP-XC12ML / GP-XC22KL: 0.02 % F.S. (64 times average processing)
Sampling frequency 40 kHz (25 μs)
Linearity (Note 2) Within ±0.3 % F.S.
Temperature characteristics (Note 3) 0.07 % F.S./℃ or less
Analog voltage outputs
(Note 4)
Output voltage: -5 to +5 V (Note 5), Output impedance: 100 Ω approx.
  Response time 75 μs (maximum speed)
Comparative outputs
(HI, GO, LO)
NPN open-collector transistor
・Maximum sink current: 100 mA
・Applied voltage: 30 V DC or less
(between comparative output and 0 V)
・Residual voltage: 1.6 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor
・Maximum source current: 100 mA
・Applied voltage: 30 V DC or less
(between comparative output and +V)
・Residual voltage: 1.6 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
  Utilization category DC-12 or DC-13
Output number HI / GO / LO 3 value output
Output operation HI : ON when measured value > the upper limit value
GO: ON when upper limit value / measured value / lower limit value
LO : ON when lower limit value > measured value
Short-circuit protection Incorporated
External input Photo-coupler input
・Input current: 9 mA or less
・Operating voltage: ON voltage 17 V or more (between +24 V and input)
・OFF voltage 4 V or less (between +24 V and input)
Input impedance: 5 kΩ approx.
Photo-coupler input
・Input current: 9 mA or less
・Operating voltage: ON voltage 17 V or more (between 0 V and input)
・OFF voltage 4 V or less (between 0 V and input)
Input impedance: 5 kΩ approx.
Serial I/O RS-232C
Zero-set setting method Push button setting / External input setting
Indicators MODE Orange LED (lights up when in mode status)
HI Orange LED (lights up when the upper limit value is exceeded)
GO Green LED (lights up when within the upper and lower limit value)
LO Orange LED (lights up when less than the lower limit value)
TIMING Green LED (lights up as per the external or internal trigger timing)
Upper level digital display part 5 digit orange LED (display of numerical values out of upper and lower limit value)
Lower level digital display part 5 digit green LED (display of numerical values within the upper and lower limit value)
Pollution degree 3 (Industrial environment)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed),
Storage: 0 to +50 ℃ +32 to +122 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Vibration resistance 10 to 55 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each
Material Enclosure: Polycarbonate
Weight Net weight: 120 g approx.
Accessory ATA4811 (Controller mounting frame): 1 set

Note 1 :Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
Note 2 :This value was obtained at a constant +25 ℃ +77 ℉.
Note 3 :This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and controller.
Note 4 :When using the BCD output unit GP-XBCD, the analog voltage output of a controller becomes invalid.
Note 5 :Adjusted to a 0 to +5 V factory setting.
Note 6 :When using as a product in conformity with EMC Directive (2014/30/EU) / EMC Regulation (2016/1091), observe the following requirements and conditions.
・The controller must be connected within 10 m of the power supply.
・The signal cable connected to the controller must be shorter than 30 m.

BCD output unit

Model No. GP-XBCD
Current consumption 20 mA or less
Outputs
(5 digits BCD,
Polarity
indication, VALID)
N-channel MOSFET open drain
・Maximum sink current: 50 mA
・Applied voltage: 30 V DC or less (between output and GND)
・Residual voltage: 1 V or less (at 50 mA sink current)
Hold input Non-voltage contact or NPN open-collector transistor input
Low: 0 to 1 V ・ High: Open
Material Enclosure: ABS
Weight Net weight: 30 g approx.
Accessory Mounting bracket [Stainless steel (SUS304)]: 1 pc.

Note 1:Connects to the control device with GP-XBCC3 cable with connector on one end for BCD output unit (3 m 9.843 ft cable length, optional).
Note 2:A ferrite clamp must be mounted within 10 mm of the base of the cable with connector on one end for BCD output unit (GP-XBCC3).

Controller communication unit

Model No. GP-XCOM
Current consumption 5 mA or less
Material Enclosure: ABS
Weight Net weight: 20 g approx.
Accessory Mounting bracket [Stainless steel (SUS304)]: 1 pc.

Note :Each GP-XCOM is connected using a link cable for controller communication units (SL-F□, optional).
When GP-XCOM is used, controllers cannot communicate if their software versions are not compatible (Ver. 1.06 or earlier version with Ver 2.00 or later version).
Check the software version and use the correct combination.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)