Model No. | IEC standards comforming type |
ANR1150 | ANR1151 | ANR1182 | ANR1115 |
FDA regulations comforming type |
ANR11501 | ANR11511 | ANR11821 | ANR11151 | |
Measurement center distance | 50 mm 1.969 in |
50 mm 1.969 in |
80 mm 3.150 in |
130 mm 5.118 in |
|
Measuring range | ±10 mm ±0.394 in |
±10 mm ±0.394 in |
±20 mm ±0.787 in |
±50 mm ±1.969 in |
|
Light source | Laser diode (Peak emission wavelength: 650 nm 0.026 mil) | ||||
Pulse width / Max.output / Laser class |
15 μs (Duty 50 %) / 0.4 mW (Peak value) / Class 1 (IEC 60825-1), (Class II for FDA regulations conforming type) | ||||
Beam spot diameter (Representative values from a measurement center distance) |
0.6 x 1.1 mm 0.024 x 0.043 in approx. |
0.09 x 0.05 mm 0.004 x 0.002 in approx. |
0.7 x 1.2 mm 0.028 x 0.047 in approx. |
0.7 x 1.4 mm 0.028 x 0.055 in approx. |
|
Resolution (2 σ) |
10Hz | 5 μm 0.197 mil |
5 μm 0.197 mil |
20 μm 0.787 mil |
100 μm 03.937 mil |
100Hz | 16 μm 0.630 mil |
16 μm 0.630 mil |
65 μm 2.559 mil |
330 μm 12.992 mil |
|
1kHz | 50 μm 1.969 mil |
50 μm 1.969 mil |
200 μm 7.874 mil |
1 mm 00.039 in |
|
Linearity error (Note 2) | Within ±0.2 % of F.S. | ||||
Protection (excluding connector) |
IP67 (IEC) | ||||
Ambient illuminance (Incandescent lamp) |
2,500 lx or less | ||||
Weight (including cable) | Net weight: 300 g approx. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) White ceramics is the target of this value.
Model No. | IEC standards comforming type |
ANR1250 | ANR1251 | ANR1282 | ANR1215 | ANR1226 |
FDA regulations comforming type |
ANR12501 | ANR12511 | ANR12821 | ANR12151 | ANR12261 | |
Measurement center distance | 50 mm 1.969 in |
50 mm 1.969 in |
80 mm 3.150 in |
130 mm 5.118 in |
250 mm 9.843 in |
|
Measuring range | ±10 mm ±0.394 in |
±10 mm ±0.394 in |
±20 mm ±0.787 in |
±50 mm ±1.969 in |
±150 mm ±5.906 in |
|
Light source | Laser diode (Peak emission wavelength: 650 nm 0.026 mil) | |||||
Pulse width / Max.output / Laser class |
15 μs (Duty 50 %) / 1.6 mW (Peak value) / Class 2 (IEC 60825-1), (Class II for FDA regulations conforming type) | |||||
Beam spot diameter (Representative values from a measurement center distance) |
0.6 x 1.1 mm 0.024 x 0.043 in approx. |
0.09 x 0.05 mm 0.004 x 0.002 in approx. |
0.7 x 1.2 mm 0.028 x 0.047 in approx. |
0.7 x 1.4 mm 0.028 x 0.055 in approx. |
0.8 x 1.5 mm 0.031 x 0.059 in approx. |
|
Resolution (2 σ) | 10Hz | 1 μm 0.039 mil |
1 μm 0.039 mil |
4 μm 0.157 mil |
20 μm 0.787 mil |
150 μm 5.906 mil |
100Hz | 3.5 μm 0.138 mil |
3.5 μm 0.138 mil |
13 μm 0.512 mil |
65 μm 2.551 mil |
500 μm 19.685 mil |
|
1kHz | 10 μm 0.394 mil |
10 μm 0.394 mil |
40 μm 1.575 mil |
200 μm 7.874 mil |
1.5 mm 0.059 in |
|
Linearity error (Note 2) | Within ±0.2 % of F.S. | Within ±0.4 % of F.S. | ||||
Protection (excluding connector) |
IP67 (IEC) | |||||
Ambient illuminance (Incandescent lamp) |
3,000 lx or less | 2,500 lx or less | ||||
Weight | Net weight: Sensor head (including cable): 240 g approx., Intermediate cable: 130 g approx. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) White ceramics is the target of this value.
Model No. | NPN output | ANR5131 | ANR5141 | ANR5231 | ANR5241 |
PNP output | ANR5132 | ANR5142 | ANR5232 | ANR5242 | |
Comparative output type | Single comparator | Window comparator | |||
Analog output | ±5 V/F.S. (2 mA max.) |
4 to 20 mA/F.S. (250 Ω max.) | ±5 V/F.S. (2 mA max.) |
4 to 20 mA/F.S. (250 Ω max.) | |
Output impedance | 50 Ω | - | 50 Ω | - | |
Zero-point adjustment | Within ±10 % of F.S. | ||||
Temperature drift (Sensor and controller set) |
Within ±(0.03 % of F.S.) /℃ | Within ±(0.04 % of F.S.) /℃ | Within ±(0.03 % of F.S.) /℃ | Within ±(0.04 % of F.S.) /℃ | |
Response frequency (-3 dB) Response time (10 to 90 %) |
1 kHz 0.4 ms/ 100 Hz 4 ms/ 10 Hz 40 ms (Switchable) | ||||
Comparative output | <NPN output type> NPN open-collector 2 Nos. (100 mA, 30 V DC or less, residual voltage 1.5 V or less) <PNP output type> PNP open collector 2 Nos. (100mA 30V DC or less, residual voltage 1.5V or less) |
<NPN output type> NPN open-collector 3 Nos. (100 mA, 30 V DC or less, residual voltage 1.5 V or less) <PNP output type> PNP open collector 3 Nos. (100mA 30V DC or less, residual voltage 1.5V or less) | |||
Hysteresis | 0.15 % of F.S. or less | ||||
Alarm output | <NPN output type> NPN open-collector 1 No. (100 mA, 30 V DC or less, residual voltage 1.5 V or less) <PNP output type> PNP open-collector 1 No. (100 mA, 30 V DC or less, residual voltage 1.5 V or less) | ||||
Intensity monitor output | ±5 V | ||||
Comparative timing Input | No voltage input (when earthing, no comparative output allowed) | ||||
MEASUREMENT SENSORS MEASUREMENT Displacement display |
Sensor head: Measuring range display LED (RANGE) | Sensor head: Measuring range display LED (RANGE) Controller: LCD 3 digit display | |||
Gain selection | AUTO / LOW (switchable) | ||||
Mutual interference prevention (Note 2) |
Between 2 sets | ||||
Operating voltage range | 12 to 24 V DC +10 /-15 % including ripple 0.5 V (P-P) | ||||
Current consumption (Sensor and controller set) |
250 mA or less (at 12 V DC), 125 mA or less (at 24 V DC) | ||||
Weight (including cable) |
Net weight: 180 g approx. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉ .
2) The value of the linearity characteristics, resolution and response time might get worse.
Insulation resistance (Initial) | Between external DC input and sensor metal parts (except for connector metal parts) 20 MΩ or more (at 500 V DC megger) |
Voltage withstandability (Initial) | Between external DC input and sensor metal parts (except for connector metal parts) AC 500 V 1 min. |
Vibration resistance (Screw installation) |
10 to 55 Hz (1 cycle/min.) double amplitude of 1.5 mm 0.059 in (controller: 0.75 mm 0.030 in), in X, Y and Z directions for two hours each |
Shock resistance (Screw installation) |
20 G or more, in X, Y and Z directions for three times each |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉, Storage: -20 to +70 ℃ -4 to +158 ℉ |
Ambient humidity | 35 % to 85 % RH (No dew condensation) |
Note:
If there is no description for measurement conditions, the test is performed under operating voltage 24 V DC, ambient temperature +20° C +68 ℉, gain AUTO, response frequency 10 Hz, interference prevention OFF and white ceramics as a target at a measurement center distance.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)