Slim body area sensor NA2 (Discontinued Products)

Specifications

Number of beam channels 12 16 20
Model No. NA2-12 NA2-16 NA2-20
Sensing height 220mm 300mm 380mm
Sensing range 5m
Beam pitch 20mm
Sensing object ø30mm or more opaque object
Supply voltage 12 to 24V DC510% Ripple P-P 10% or less
Power consumption (Note) Emitter: 0.5W or less
(0.4W or less when job indicator is off)
Receiver: 0.8W or less
(0.7W or less when job indicator is off)
Emitter: 0.5W or less
(0.4W or less when job indicator is off)
Receiver: 0.9W or less
(0.8W or less when job indicator is off)
Emitter: 0.5W or less
(0.4W or less when job indicator is off)
Receiver: 1.0W or less
(0.9W or less when job indicator is off)
Output NPN open-collector transistor
・Maximum sink current: 100mA
・Applied voltage: 30V DC or less (between output and 0V)
・Residual voltage:
1V or less (at 100mA sink current)
0.4V or less (at 16mA sink current)
  Output operation ON when all beams are received
(OFF when one or more beams are interrupted)
Short-circuit protection Incorporated
Indicators Emitter Power indicator: Green LED x 2(light up when the power is ON; emission frequency (a) or (b) is indicated by the number of LEDs lighting up)
Job indicator: Red LED (lights up, blinks, or lights off when the job indicator input is at Low; lighting pattern is selected by operation mode switch)
Receiver Operation indicator: Red LED (lights up when one or more beams are interrupted, and blinks alternately with the stable incident beam indicator when an abnormal condition is found out by the test-run)
Stable incident beam indicator: Green LED (lights up when all beams are stably received, and blinks alternately with the operation indicator when an abnormal condition is found out by the test-run)
Job indicator: Red LED (lights up, blinks, or lights off when the job indicator input is at Low; lighting pattern is selected by operation mode switch)
* When an excess current flows through the output, the stable incident beam indicator and the operation indicator on the receiver blink simultaneously due to the operation of the short-circuit protection circuit.
Interference prevention function Incorporated
Test-run function Incorporated
Environmental resistance Ambient temperature -10 to +55 ℃ (No dew condensation or icing allowed), Storage: -10 to 60 ℃
Ambient humidity 35 to 85% RH, Storage: 35 to 85% RH
Ambient illuminance Sunlight: 10,000lx at the light-receiving face, Incandescent light: 3,000lx at the light-receiving face
Noise immunity Power line: 240Vp, 10ms cycle, and 0.5μs pulse width
Radiation: 300Vp, 10ms cycle, and 0.5μs pulse width (with noise simulator)
Voltage withstandability 1,000V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance 20M½, or more, with 250V DC megger between all supply terminals connected together and enclosure
Vibration resistance 10 to 150Hz frequency, 0.75mm amplitude in X, Y and Z directions for two hours each
Shock resistance 490m/s2 acceleration (50G approx.) in X, Y and Z directions for three times each
Emitting element Infrared LED (modulated)
Material Enclosure: Heat-resistant ABS, Lens cover: Polyester, Indicator cover: Acrylic
Cable 0.2mm2 4-core cabtyre cable, 3m long
Cable extension Extension up to total 25m is possible for both emitter and receiver, with 0.2m2, or more, cable.
Weight 400g approx. 450g approx. 500g approx.

(Note) :Obtain the current consumption from the following equation.

Current consumption4Power consumption3Supply voltage
(e.g.) When the supply voltage is 12V, the current consumption of the emitter is: 0.5W÷12V ≈ 0.042A = 42mA.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)