Response time of FX-550 / FX-550L series is as follows.
Note: FX-550L series does not have FAST mode.
Mode | FAST | STD | LONG | U-LG | HYPR |
---|---|---|---|---|---|
Response time | 60μs or less | 250μs or less | 2ms or less | 4ms or less | 24ms or less |
■Thru-beam type(one pair set)
Type | Model No. | Sensing range(mm)(Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Square head | M3 | FT-R31 | 310 | 510 | 700 | 1,120 | 1,670 |
M4 | FT-R43 | 750 | 1,250 | 1,750 | 2,650 | 3,600(Note2) | |
FT-R41W | 800 | 1,300 | 1,850 | 2,900 | 3,600(Note2) | ||
FT-R42W | 2,800 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-R44Y | 800 | 1,300 | 1,800 | 2,900 | 3,600(Note2) | ||
M6 | FT-R60Y | 1,900 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) |
Note1: | Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Note1: | Note that sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note2: | The sensing range is specified for white non-glossy paper. |
For details of Square Head Fiber, refer to product information page.
>>Go to "Square Head Fiber"
■Thru-beam type (one pair set)
Note: | The fiber cable length practically limits the sensing range. |
---|
■Reflective type
Note: | The sensing range is specified for white non-glossy paper. |
---|
For details of Super Quality Fiber, refer to product information page.
>>Go to "Super Quality Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | M3 | FT-31 | 290 | 480 | 700 | 1,000 | 1,580 | |
FT-31W | 250 | 420 | 580 | 890 | 1,300 | |||
FT-32 | 2,900 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |||
M4 | FT-43 | 1,400 | 2,200 | 3,100 | 3,600(Note2) | 3,600(Note2) | ||
FT-42 | 890 | 1,470 | 2,100 | 2,900 | 3,600(Note2) | |||
FT-42W | 710 | 1,200 | 1,780 | 2,600 | 3,600(Note2) | |||
FT-45X | 1,070 | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | |||
Elbow | FT-R40 | 860 | 1,400 | 1,950 | 2,900 | 3,600(Note2) | ||
M14 | Long range | FT-140 | 19,600(Note2) | 19,600(Note2) | 19,600(Note2) | 19,600(Note2) | 19,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | M3 | FD-31 | 140 | 200 | 310 | 450 | 750 | |
FD-31W | 80 | 130 | 190 | 310 | 480 | |||
FD-32G | 170 | 320 | 420 | 730 | 1,150 | |||
FD-32GX | 180 | 320 | 490 | 730 | 1,350 | |||
FD-34G | 80 | 130 | 180 | 310 | 480 | |||
Ultra-small diameter | FD-EG30 | 50 | 90 | 120 | 190 | 320 | ||
FD-EG31 | 20 | 35 | 45 | 70 | 120 | |||
M4 | FD-41 | 140 | 200 | 310 | 450 | 750 | ||
FD-41W | 270 | 480 | 680 | 1,000 | 1,400 | |||
FD-42G | 170 | 320 | 420 | 730 | 1,150 | |||
FD-42GW | 130 | 210 | 330 | 540 | 950 | |||
M6 | FD-62 | 550 | 880 | 1,140 | 1,450 | 1,950 | ||
FD-61 | 380 | 620 | 870 | 1,180 | 1,630 | |||
FD-61W | 270 | 480 | 680 | 1,000 | 1,400 | |||
FD-61G | 350 | 600 | 850 | 1,200 | 1,350 | |||
FD-64X | 230 | 410 | 590 | 700 | 1,200 | |||
Elbow | FD-R60 | 350 | 500 | 800 | 1,150 | 1,450 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Threaded Type Fiber, refer to product information page.
>>Go to "Threaded Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Cylindrical | ø1 | FT-S11 | 80 | 130 | 180 | 280 | 400 | |
ø1.5 | FT-S21 | 280 | 450 | 670 | 1,000 | 1,600 | ||
FT-S21W | 240 | 400 | 580 | 850 | 1,650 | |||
FT-S22 | 530 | 870 | 1,200 | 1,900 | 2,900 | |||
ø2.5 | FT-S32 | 3,000 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
ø3 | FT-S31W | 650 | 1,100 | 1,600 | 2,450 | 3,600(Note2) | ||
Ultra-small diameter |
ø3 | FT-E13 | 12 | 21 | 30 | 45 | 68 | |
FT-E23 | 70 | 120 | 165 | 250 | 355 | |||
Side-view | ø4 | FT-V40 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Cylindrical | ø1.5 | FD-S21 | 50 | 85 | 110 | 130 | 175 | |
ø3 | FD-S32 | 350 | 600 | 900 | 1,200 | 1,600 | ||
FD-S32W | 250 | 450 | 650 | 1,000 | 1,400 | |||
FD-S31 | 130 | 200 | 300 | 450 | 700 | |||
FD-S33GW | 150 | 240 | 370 | 550 | 880 | |||
FD-S34G | 80 | 130 | 180 | 310 | 480 | |||
Ultra-small diameter |
ø1.5 | FD-E13 | 12 | 23 | 30 | 50 | 75 | |
ø3 | FD-E23 | 45 | 80 | 105 | 170 | 290 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Cylindrical Type Fiber, refer to product information page.
>>Go to "Cylindrical Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | M3 | FT-31S | 290 | 480 | 700 | 1,000 | 1,580 | |
M4 | FT-42S | 890 | 1,470 | 2,100 | 2,900 | 3,600(Note2) | ||
Cylindrical | Ultra-small diameter | ø3 | FT-E13 | 12 | 21 | 30 | 45 | 68 |
FT-E23 | 70 | 120 | 165 | 250 | 355 | |||
Side-view | ø2 | FT-V23 | 450 | 750 | 1,050 | 1,600 | 2,400 | |
FT-V25 | 280 | 450 | 630 | 950 | 1,400 | |||
FT-V24W | 95 | 160 | 220 | 350 | 500 | |||
ø2.5 | FT-V30 | 550 | 950 | 1,300 | 1,950 | 3,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Threaded | Ultra-small diameter | M3 | FD-EG30S | 50 | 90 | 120 | 190 | 320 |
M4 | FD-41S | 140 | 200 | 310 | 450 | 750 | ||
FD-41SW | 80 | 130 | 190 | 310 | 480 | |||
M6 | FD-61S | 400 | 650 | 900 | 1,300 | 1,900 | ||
Cylindrical | Ultra-small diameter | ø1.5 | FD-E13 | 12 | 23 | 30 | 50 | 75 |
ø3 | FD-E23 | 45 | 80 | 105 | 170 | 290 | ||
Side-view | ø3 | FD-V30 | 65 | 90 | 145 | 210 | 430 | |
FD-V30W | 16 | 30 | 37 | 65 | 120 | |||
ø5 | FD-V50 | 110 | 180 | 240 | 400 | 530 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Sleeve Fiber, refer to product information page.
>>Go to "Sleeve Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Flat | FT-Z30H | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-Z30HW | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30E | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30EW | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30 | 2,200 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-Z30W | 1,700 | 2,800 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
With boss | FT-Z20W | 650 | 1,100 | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | |
FT-Z20HBW | 280 | 450 | 650 | 1,000 | 1,600(Note2) | ||
FT-Z40W | 1,200 | 2,000 | 2,800 | 3,600(Note2) | 3,600(Note2) | ||
FT-Z40HBW | 750 | 1,300 | 1,850 | 2,700 | 3,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Flat Type Fiber, refer to product information page.
>>Go to "Flat Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Narrow beam |
FT-KS40 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
Side view | FT-KV40 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-KV40W | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | ||
FT-KV26 | 650 | 1,100 | 1,600 | 2,300 | 3,600(Note2) | ||
FT-KV26H1 | 650 | 1,000 | 1,400 | 1,900 | 3,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Retroreflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
With polarizing filters | FR-Z50HW | 100 to 950 |
100 to 1,150 |
100 to 1,400 |
100 to 1,800 |
100 to 2,250 |
|
Wafer mapping | FR-KZ22E | 15 to 400 |
15 to 540 |
15 to 600 |
15 to 700 |
15 to 800 |
|
Narrow beam |
Top sensing |
FR-KZ50H | 20 to 350 |
20 to 400 |
20 to 500 |
20 to 1,300 |
20 to 1,600 |
Side sensing |
FR-KZ50E | 20 to 350 |
20 to 400 |
20 to 500 |
20 to 1,300 |
20 to 1,600 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. |
■Reflective type
Type | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Long range | FD-Z50HW | 10 to 590 |
10 to 950 |
10 to 1,300 |
10 to 2,100 |
10 to 3,700 |
Note: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|
For details of Narrow Beam Fiber, refer to product information page.
>>Go to "Narrow Beam Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note1) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Wide beam | FT-A32 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) |
FT-A32W | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-A11 | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
FT-A11W | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | 3,600(Note2) | |
Array | FT-AL05 | 660 | 1,150 | 1,600 | 2,350 | 3,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range to 3,600 mm long. |
■Reflective type
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Wide Beam Fiber, refer to product information page.
>>Go to "Wide Beam Fiber"
■Reflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Glass substrate detection | FD-L32H | 0 to 50 | 0 to 65 | 0 to 75 | 0 to 90 | 0 to 100 |
FD-L30A | 0 to 46 | 0 to 52 | 0 to 62 | 0 to 68 | 0 to 72 | |
FD-L31A | 3 to 40 | 3 to 42 | 3 to 42 | 2 to 43 | 0 to 50 | |
FD-L22A | 0 to 32 | 0 to 34 | 0 to 35 | 0 to 35 | 0 to 35 | |
FD-L23 | 0 to 32 | 0 to 34 | 0 to 34 | 0 to 34 | 0 to 34 | |
FD-L11 | 0 to 12 | 0 to 13 | 0 to 13 | 0 to 13 | 0 to 14 | |
FD-L10 | 0 to 5 | 0 to 5 | 0 to 5.5 | 0 to 5.5 | 0 to 6 | |
FD-L21 | 2 to 18 | 1 to 19 | 1 to 19 | 1 to 20 | 1 to 20 | |
FD-L21W | 3 to 17 | 2 to 18 | 2 to 18 | 1 to 19 | 1 to 19 | |
General purpose | FD-L20H | 0 to 25 | 0 to 33 | 0 to 40 | 0 to 50 | 0 to 65 |
Ultla-small | FD-L12W | 0 to 10 | 0 to 12 | 0 to 15 | 0 to 16 | 0 to 17 |
Note 1: | The sensing range is specified for transparent glass 100 x 100 x t0.7 mm (FD-L32H: R edge, FD-L21 and FD-L21W: t2 mm) (FD-L20H: white non-glossy paper, FD-L10: silicon wafers 100 x 100 mm). |
---|---|
Note 2: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
For details of Convergent Reflective Type Fiber, refer to product information page.
>>Go to "Convergent Reflective Type Fiber"
■Retroreflective type
Type | Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
With polarizing filters | FR-Z50HW | 100 to 950 |
100 to 1,150 |
100 to 1,400 |
100 to 1,800 |
100 to 2,250 |
|
Wafer mapping | FR-KZ22E | 15 to 400 |
15 to 540 |
15 to 600 |
15 to 700 |
15 to 800 |
|
Narrow beam |
Top sensing |
FR-KZ50H | 20 to 350 |
20 to 400 |
20 to 500 |
20 to 1,300 |
20 to 1,600 |
Side sensing |
FR-KZ50E | 20 to 350 |
20 to 400 |
20 to 500 |
20 to 1,300 |
20 to 1,600 |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The sensing range is the possible setting range for the attached reflector. The fiber can detect an object less than setting range for the reflector. |
For details of Retroreflective Type Fiber, refer to product information page.
>>Go to "Retroreflective Type Fiber"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) (Note 1) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Chemical-resistant | FT-Z802Y | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) |
FT-HL80Y | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | |
FT-L80Y | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) | |
FT-V80Y | 1,400 | 2,200 | 3,600(Note 2) | 3,600(Note 2) | 3,600(Note 2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Model No. | Sensing range(mm)(Note 1)(Note 2) | ||||
---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||
Chemical-resistant | FD-S60Y | 380 | 450 | 550 | 700 | - |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending on how the fiber is cut. |
---|---|
Note 2: | The sensing range is specified for white non-glossy paper. |
For details of Chemical-resistant Fiber, refer to product information page.
>>Go to "Chemical-resistant Fiber"
■Thru-beam type (one pair set)
Type | Heat-resistant temp. |
Model No. | Sensing range(mm) (Note1) | ||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Heat-resistant | 350℃ | FT-H35-M2 | 650 | 1,050 | 1,500 | 2,300 | 3,600(Note2) |
FT-H35-M2S6 | 650 | 1,050 | 1,500 | 2,300 | 3,600(Note2) | ||
200℃ | FT-H20W-M1 | 440 | 730 | 1,050 | 1,600(Note2) | 1,600(Note2) | |
FT-H20-M1 | 600 | 1,000 | 1,600(Note2) | 1,600(Note2) | 1,600(Note2) | ||
130℃ | FT-H13-FM2 | 750 | 1,150 | 1,690 | 2,700 | 3,600(Note2) | |
HHeat-resistant (joint) | 200℃ | FT-H20-J20-S | 530 | 860 | 1,200 | 1,800 | 2,600 |
FT-H20-J30-S | 530 | 860 | 1,200 | 1,800 | 2,600 | ||
FT-H20-J50-S | 530 | 860 | 1,200 | 1,800 | 2,600 | ||
FT-H20-VJ50-S | 620 | 1,000 | 1,400 | 2,200 | 3,600(Note2) | ||
FT-H20-VJ80-S | 620 | 1,000 | 1,400 | 2,200 | 3,600(Note2) |
Note 1: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|---|
Note 2: | The fiber cable length practically limits the sensing range. |
■Reflective type
Type | Heat-resistant temp. |
Model No. | Sensing range(mm) (Note1)(Note2) | |||||
---|---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | ||||
Heat-resistant | Threaded | 350℃ | FD-H35-M2 | 220 | 400 | 500 | 600 | 750 |
FD-H35-M2S6 | 220 | 400 | 500 | 600 | 750 | |||
FD-H35-20S | 230 | 410 | 550 | 750 | 850 | |||
200℃ | FD-H20-M1 | 300 | 450 | 650 | 1,000 | 1,350 | ||
FD-H20-21 | 250 | 450 | 650 | 850 | 1,250 | |||
130℃ | FD-H13-FM2 | 390 | 670 | 940 | 1,300 | 1,650 | ||
Glass substrate detection convergent reflective | 300℃ | FD-H30-L32 | 0 to 16 | 0 to 21 | 0 to 25 | 0 to 42 | 0 to 60 | |
250℃ | FD-H25-L43 | 1 to 26 | 1 to 28 | 1 to 29 | 1 to 30 | 1 to 31 | ||
FD-H25-L45 | 4 to 44 | 4 to 48 | 4 to 49 | 4 to 50 | 4 to 51 | |||
180℃ | FD-H18-L31 | 0 to 30 | 0 to 45 | 0 to 60 | 0 to 85 | 0 to 130 |
Note 1: | The sensing range of reflective type is the value for white non-glossy paper (50 x 50 mm glass substrate for FD-H30-L32 and FD-H18-L31, transparent glass 100 x 100 x t0.7 mm for FD-H25-L43 and FD-H25-L45). |
---|---|
Note 2: | Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
For details of Heat-resistant Fiber, refer to product information page.
>>Go to "Heat-resistant Fiber"
■Thru-beam type
Type | Model No. | Sensing range (mm)(Note 1) | |||||
---|---|---|---|---|---|---|---|
HYPR | U-LG | LONG | STD | FAST | |||
Vacuum- resistant |
Thru-beam | FT-40V | 1,400 | 950 | 620 | 400 | 250 |
(Note 1): | Atmospheric side fiber, FT-J9 (optional) is free-cut type. Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
---|
■Reflective type
(Note 1): | The sensing range is the value for transparent glass 100 × 100 × t0.7 mm 3.937 × 3.937 × t0.028 in. |
---|---|
(Note 2): | Atmospheric side fiber, FT-J9 (optional) is free-cut type. Note that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut. |
For details of One-Touch Connection System Vacuum-resistant Fibers, refer to product information page.
>>Go to "One-Touch Connection System Vacuum-resistant Fibers"
■Thru-beam type (one pair set)
Type | Model No. | Sensing range(mm) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Vacuum-resistant | Thru-beam | FT-H30-M1V-S | 250 | 400 | 620 | 950 | 1,400 |
■Reflective type
Type | Model No. | Sensing range(mm) (Note1) | |||||
---|---|---|---|---|---|---|---|
FAST | STD | LONG | U-LG | HYPR | |||
Vacuum-resistant | Reflective | FD-H30-KZ1V-S | 20 to 300 | 20 to 450 | 15 to 650 | 10 to 1,000 | 5 to 1,500 |
Convergent reflective |
FD-H30-L32V-S | 0 to 7.5 | 0 to 11 | 0 to 13 | 0 to 19 | 0 to 27 |
Note: | The sensing range of reflective type is the value for transparent glass 100 x 100 x t0.7 mm. |
---|
For details of Vacuum-resistant Fiber, refer to product information page.
>>Go to "Vacuum-resistant Fiber"
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)