Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Fiber Sensors > External Input Unit for Digital Sensor FX-CH2 > Specifications
|
Type | NPN input | PNP input |
Model No. | FX-CH2 | FX-CH2-P |
Applicable sensors | FX-301(P) (Note 2), FX-305(P) | |
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less | |
Power consumption | 600 mW or less (when all indicators light up) | |
Input | Low: 0 to +2 V DC Source current 0.5 mA Input impedance 10 kΩ approx. High: +5 V to +V DC, or open |
High: +4 V to +V DC Sink current 0.5 to 3 mA Input impedance 10 kΩ approx. Low: 0 to +0.6 V DC, or open |
Power indicator | Green LED (Lights up when the power is ON) | |
Transmission operation indicator |
Green LED (Lights up when loaded, and 2-level / Limit teaching, blinks → lights up when saved, and Full-auto teaching) |
|
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 sensors are connected in cascade: -10 to +50 ℃ +14 to +122 ℉, if 8 to 16 sensors are connected in cascade: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
|
Material | Enclosure: Heat-resistant ABS | |
Connection method | Connector (Note 3) | |
Weight | Net weight: 20 g approx., Gross weight: 40 g approx. | |
Dimensions | W10 x H27 x D68.5 mm W0.394 x H1.063 x D2.697 in | |
Accessory | CN-EP1 (Connector for input device) (Note 4): 1 pc. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 ℃ +68 ℉.
2) Only updated version of FX-301(P) can be used. Do not use the previous version of FX-301(P).
The updated version of FX-301(P) have "NAVI" printed on one side. (See the right figure.)
|
3) The cable for unit connection is not supplied as an accessory. Be sure to use the optional quick-connection cables given below.
Main cable (3-core):
CN-73-C1 (cable length 1 m 3.281 ft)
CN-73-C2 (cable length 2 m 6.562 ft)
CN-73-C5 (cable length 5 m 16.404 ft)
4) The applicable wire is 0.08 mm2 (AWG 28) to 0.5 mm2 (AWG 20) and the wire sheath diameter should be ø1.5 mm ø0.059 in or less.
5) Make sure that FX-CH2(-P) should be mounted to a 35 mm 1.375 in width DIN rail.
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)