Upper Communication Unit for Digital Sensors SC-GU1-485

Proposal of a new "management and setting" method for sensors

Upper Communication Unit for Digital Sensors  SC-GU1-485
CE Marking

CE Approved

Features

Control and settings can be carried out remotely

Setting and checking incident light intensity for digital sensors FX-501/502/301/305, LS-501/403, DPS-401/402 and input unit SC-A01/A02/T1JA that are scattered inside and outside equipment can be carried out remotely for all sensors by using the SC-GU1-485, which greatly improves ease of operations such as monitoring equipment that is running and also equipment starting and maintenance.

Note:
Used when the output signal is sent via a SC-GU1-485 to the PLC. If the output signal is sent directly to the PLC, a quick-connection cable (CN-72-C□, CN-71-C□) should be used.

High general applicability so that any type of PLC can be used

RS-485 communication provides a high level of general compatibility so that any type of PLC can be used. Integration with existing systems is possible without the need to change PLCs.

High general applicability so that any type of PLC can be used

Communication speed 57.6 kbps

High-speed communication at a maximum speed of 57.6 kbperator to instantly check information such as the incident light intensity and output statuses of the digital sensors.

Series connection of a maximum of 31 nodes is possible

A maximum of 31 nodes can be connected in series. This is ideal for flexible handling when the sensors are to be installed in scattered locations or if more sensors are added.

Series connection of a maximum of 31 nodes is possible

Less wiring and installation work

Up to a maximum of 16 sensors can be connected side by side. Power can be supplied to all of them at once, so that less wiring and installation work is required. Wire-saving connectors also makes it possible to send output signals to the PLC in a single batch.

Less wiring and installation work

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



BY PHONE

FAQ


Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)