AUTOMATION
CONTROLS

Search
Discontinued
Products



Guide to interchanging fiber length and sleeve length

Fiber lineup

Applicable models

Thru-beam type

Basic specifications Applicable
fiber length
Model No. Fiber cable
length
Free-cut Protective tube
extension length
Sleeve length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
Max.
(m)
Unit
(m)
FT-140 10m - - 19,600(Note 2) 30 1
FT-30 2m - - - 400 10 0.1
FT-31 2m - - 315 30 1
FT-31S 2m - 40mm(Note 3) 315 30 1
FT-31W 2m - - 260 20 1
FT-32 2m - - 3,000 30 1
FT-40 2m - - - 1,200 10 0.1
FT-40V 1m - - - 270 6.5 0.1
FT-42 2m - - 1,130 30 1
FT-42S 2m - 40mm(Note 3) 1,130 30 1
FT-42W 2m - - 800 20 1
FT-43 2m - - 1,400 30 1
FT-45X 1m - - - 1,200 10 0.5
FT-A11 2m - - 3,600(Note 2) 10 1
FT-A11W 2m - - 3,600(Note 2) 10 1
FT-A32 2m - - 3,600(Note 2) 10 1
FT-A32W 2m - - 3,600(Note 2) 10 1
FT-AL05 2m - - 860 20 1
FT-E13 1m - 5mm 15 10 0.5
FT-E23 1m - 5mm 75 10 0.5
FT-F93 2m 1m(Note 4) - - 25 1
FT-H13-FM2 2m - - 700 20 1
FT-H20-J50-S 500mm(Note 5) - - 470 6.5 0.1
FT-H20-M1 1m - - - 540 6.5 0.1
FT-H20-VJ80-S 800mm(Note 5) - - 600 6.5 0.1
FT-H20W-M1 1m - - - 470 6.5 0.1
FT-H30-M1V-S 1m - - - 270 6.5 0.1
FT-H35-M2 2m - - - 430 6.5 0.1
FT-H35-M2S6 2m - - 55mm 430 6.5 0.1
FT-HL80Y 2m(Note 6) 1.5m(Note 4) - 3,600(Note 2) 30 1
FT-J8 2m - - - 30 1
FT-J9 2m - - - 30 1
FT-KS40 2m - - 3,600(Note 2) 10 1
FT-KV26 2m - - 710 10 1
FT-KV26H1 2m - - 630 10 1
FT-KV40 2m - - 3,600(Note 2) 10 1
FT-KV40W 2m - - 3,600(Note 2) 10 1
FT-L80Y 2m(Note 6) 1.5m(Note 4) - 3,600(Note 2) 30 1
FT-R31 2m - - 270 30 1
FT-R40 2m - - 930 30 1
FT-R41W 2m - - 800 20 1
FT-R42W 2m - - 2,200 20 1
FT-R43 2m - - 720 30 1
FT-R44Y 2m - - 720 30 1
FT-R60Y 2m - - 2,100 30 1
FT-S11 500mm - - - 90 30 1
FT-S20 2m - - - 400 10 0.1
FT-S21 2m - - 315 30 1
FT-S21W 2m - - 260 20 1
FT-S22 2m - - 450 30 1
FT-S30 2m - - - 1,200 10 0.1
FT-S31W 2m - - 800 20 1
FT-S32 2m - - 3,100 30 1
FT-V23 2m - 20mm 450 30 1
FT-V24W 2m - 15mm 110 10 1
FT-V25 2m - 15mm 240 30 1
FT-V30 2m - 20mm 680 30 1
FT-V40 2m - - 3,500 30 1
FT-V80Y 2m(Note 6) 1.5m(Note 4) - 3,600(Note 2) 30 1
FT-Z20HBW 1m - - 260 20 1
FT-Z20W 1m - - 620 20 1
FT-Z30 2m - - 2,100 30 1
FT-Z30E 2m - - 3,500 30 1
FT-Z30EW 2m - - 3,400 20 1
FT-Z30H 2m - - 3,500 30 1
FT-Z30HW 2m - - 3,500 20 1
FT-Z30W 2m - - 1,500 20 1
FT-Z40HBW 2m - - 800 20 1
FT-Z40W 2m - - 1,500 20 1
FT-Z802Y 2m - - 3,100 30 1

Models which can have extended sleeve : FT-31S, FT-42S
Models which can have extended protective tube (fluorine resin) : FT-F93, FT-HL80Y, FT-L80Y, FT-V80Y

Note 1: Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.
Note 2: The fiber cable length practically limits the sensing range.
Note 3: Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in.
Note 4: Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft.
Note 5: Fiber length (fixed-length) for heat-resistant fiber side. Fiber length for ordinary temperature side is 2 m 6.562 ft (free-cut).
Note 6: The allowable cutting range is 500 mm 19.685 in from the end that the amplifier inserted.

Return to Applicable models

Reflective type

Basic specifications Applicable
fiber length
Model No. Fiber cable
length
Free-cut Protective tube
extension length
Sleeve length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
Max.
(m)
Unit
(m)
FD-30 2m - - - 160 10 0.1
FD-31 2m - - 125 30 1
FD-31W 2m - - 80 20 1
FD-32G 2m - - 200 30 1
FD-32GX 1m 300mm(Note 3) - 200 30 1
FD-34G 2m - - 90 30 1
FD-40 2m - - - 160 10 0.1
FD-41 2m - - 125 30 1
FD-41S 2m - 40mm(Note 2) 125 30 1
FD-41SW 2m - 40mm(Note 2) 80 20 1
FD-41W 2m - - 270 20 1
FD-42G 2m - - 200 30 1
FD-42GW 2m - - 150 20 1
FD-60 2m - - 520 10 0.1
FD-61 2m - - 450 30 1
FD-61G 2m - - 420 30 1
FD-61S 2m - 40mm(Note 2) 420 30 1
FD-61W 2m - - 270 20 1
FD-62 2m - - 520 30 1
FD-64X 1m - - - 280 10 0.5
FD-A16 2m - - 200 30 1
FD-AL11 2m - - 320 20 1
FD-E13 1m - - 3mm 12 3 0.1
FD-E23 1m - - 5mm 55 3 0.1
FD-EG30 500mm - - - 48 3 0.1
FD-EG30S 1m - - 15mm 50 3 0.1
FD-EG31 500mm - - - 20 3 0.1
FD-F4 2m - - - 10 1
FD-F41 2m - - - 10 1
FD-F41Y 2m 500mm - - 5 1
FD-F71 5m 3m(Note 3) - - 25 1
FD-FA93 2m - - - 10 1
FD-H13-FM2 2m - - 350 20 1
FD-H18-L31 2m - - 16 5 1
FD-H20-21 1m - - - 230 6.5 0.1
FD-H20-M1 1m - - - 330 6.5 0.1
FD-H25-L43 3m - - - 1.5 to 26 5 0.1
FD-H25-L45 3m - - - 5 to 42 5 0.1
FD-H30-KZ1V-S 1m - - - 20 to 200 6.5 0.1
FD-H30-L32 2m - - - 17 5 1
FD-H30-L32V-S 3m - - - 8 5 0.1
FD-H35-20S 1m - - 90mm 260 6.5 0.1
FD-H35-M2 2m - - - 260 6.5 0.1
FD-H35-M2S6 2m - - 55mm 260 6.5 0.1
FD-HF40Y 2m 500mm - - 5 1
FD-KZ50V 1m - - - 20 to 200 6.5 0.1
FD-L10 2m - - 0 to 5 5 1
FD-L10V 3m - - - 0 to 8 5 0.1
FD-L11 2m - - 0 to 9.5 5 1
FD-L12W 1m - - 8 5 1
FD-L20H 2m - - 30 5 1
FD-L21 2m - - 1.5 to 16 5 1
FD-L21W 2m - - 3 to 14 5 1
FD-L22A 2m - - 0 to 24 5 1
FD-L23 3m - - 0 to 29 5 1
FD-L30A 3m - - 0 to 43 5 1
FD-L31A 3m - - 4 to 33 5 1
FD-L32H 4m - - 0 to 56 5 1
FD-R31G 2m - - 170 30 1
FD-R32EG 500mm - - - 45 3 0.1
FD-R33EG 500mm - - - 19 3 0.1
FD-R34EG 500mm - - - 38 3 0.1
FD-R41 2m - - 210 30 1
FD-R60 2m - - 290 30 1
FD-R61Y 2m - - 280 30 1
FD-S21 1m - - - 80 20 1
FD-S30 2m - - - 160 10 0.1
FD-S31 2m - - 125 30 1
FD-S32 2m - - 420 30 1
FD-S32W 2m - - 270 20 1
FD-S33GW 2m - - 150 20 1
FD-S34G 2m - - 90 30 1
FD-S60Y 2m(Note4) 1.5m(Note3) - 320 30 1
FD-V30 2m - 15mm 65 30 1
FD-V30W 2m - 15mm 20 10 1
FD-V50 2m - 20mm 120 30 1
FD-Z20HBW 1m - - 2 to 85 20 1
FD-Z20W 1m - - 1 to 65 20 1
FD-Z40HBW 2m - - 260 20 1
FD-Z40W 2m - - 190 20 1
FD-Z50HW 2m - - 10 to 650 20 1

Models which can have extended sleeve : FD-41S, FD-41SW, FD-61S
Models which can have extended protective tube (fluorine resin) : FD-F71
Models which can have extended stainless jacket sheath : FD-32GX

Note 1: Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.
Note 2: Applicable sleeve lengh is from 10 to 120 mm 0.394 to 4.724 in and in units of 10 mm 0.394 in.
Note 3: Applicable protective lengh is up to 10 m 32.808 ft and in units of 0.5 m 1.640 ft . (however, FD-32GX is in units of 0.1 m 0.328 ft.)
Note 4: The allowable cutting range is 500 mm 19.685 in from the end that is inserted to the amplifier.

Return to Applicable models

Retroreflective type

Basic specifications Applicable
fiber length
Model No. Fiber cable
length
Free-cut Protective tube
extension length
Sleeve length
(mm)
Sensing range
(mm)
FX-500 series
(STD)(Note 1)
Max.
(m)
Unit
(m)
FR-KZ22E 2m - - 15 to 310 10 1
FR-KZ50E 2m - - 20 to 300 10 1
FR-KZ50H 2m - - 20 to 300 10 1
FR-Z50HW 2m - - 100 to 990 10 1
Note 1: Note that the sensing range of the free-cut type fiber may be reduced by 20% max. depending upon how the fiber is cut.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)