[System Maintenance Notice]
Due to ongoing system maintenance, the site search and specification search functions are temporarily unavailable. We apologize for any inconvenience this may cause and appreciate your understanding.
【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Photoelectric Sensors / Laser Sensors > Compact Multi-voltage Photoelectric Sensor NX5 > Specifications
Discontinuation plan
|
|
Type | Thru-beam | ||||
---|---|---|---|---|---|
Long sensing range | |||||
Model No. | NX5-M10RA | NX5-M10RB | NX5-M30A | NX5-M30B | |
Regulatory compliance | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 |
||||
Sensing range | 10 m 32.808 ft |
30 m 98.425 ft |
|||
Sensing object | φ20 mm φ0.787 in or more opaque object (Note 2) |
φ20 mm φ0.787 in or more opaque object (Completely beam interrupted object) (Note 2) |
|||
Hysteresis | - | ||||
Repeatability (perpendicular to sensing axis) |
0.1 mm 0.004 in or less | 0.2 mm 0.008 in or less | |||
Supply voltage | 24 to 240 V AC +10–15 % or 12 to 240 V DC +10–15 % Ripple P-P 10 % or less | ||||
Power consumption | Emitter: 1 VA or less Receiver: 2 VA or less |
Emitter: 1.5 VA or less Receiver: 2 VA or less |
|||
Output | Relay contact 1 c • Switching capacity: 250 V AC 1 A (resistive load) 30 V DC 2 A (resistive load) • Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) 100,000 or more switching operations (switching frequency 3,600 operations/hour) • Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
||||
Output operation | Light-ON | Dark-ON | Light-ON | Dark-ON | |
Response time | 10 ms or less | ||||
Operation indicator | Red LED (lights up when the output is ON) | ||||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
||||
Power indicator | - | Red LED (lights up when the power is ON) |
|||
Sensitivity adjuster | Continuously variable adjuster | - | |||
Automatic interference prevention function |
(Use optional interference prevention filters) |
- | |||
Pollution degree | 3 (Industrial environment) | ||||
Protection | IP66 (IEC) | ||||
Ambient temperature | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note 3), Storage: –30 to +70 ℃ –22 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face | ||||
Voltage withstandability | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals |
||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | ||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions two hours each | ||||
Shock resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions three times each | ||||
Emitting element | Red LED (modulated) | Infrared LED (modulated) | |||
Peak emission wavelength |
660 nm 0.026 mil | 880 nm 0.035 mil | |||
Material | Enclosure: Polycarbonate, Lens: Polycarbonate, Cover: Polycarbonate | ||||
Cable | 0.3 mm2 5-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | ||||
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver). | ||||
Net weight | Emitter: 100 g approx. Receiver: 140 g approx. |
Emitter: 125 g approx. Receiver: 140 g approx. |
|||
Accessories | Adjusting screwdriver: 1 pc. | - |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2) | If slit masks (optional) are fitted, an object as small as 3 x 6 mm 0.118 x 0.236 in can be detected. |
3) | In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. |
Type | Thru-beam | |||
---|---|---|---|---|
Long sensing range | ||||
Model No. | NX5-M10RA | NX5-M10RB | NX5-M30A | NX5-M30B |
Utilization category | AC-12/DC-12 | |||
Impulse withstand voltage | 2.5kV | |||
Output minimum operational current | DC5V 1mA or more | |||
Turn on time / Turn off time (Note 4) | 10ms / 10ms | |||
Maximum response frequency (Note 5) | 50Hz | |||
Pollution degree | 3 (Industrial environment) | |||
Class of protection against electric shock | Out of classification | |||
Excess gain | 30% (Note 6) | 30% |
Note:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2) | The output applied voltage should be the same as the supply voltage of the sensor. |
3) | Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output. In addition, use 3A or less fast blow fuse or breaker. |
4) | Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. |
5) | The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) |
6) | Excess gain of NX5-M10□ is the value in case sensitivity aduster is in maximum position. |
Type | Retroreflective | Diffuse reflective | |||||
---|---|---|---|---|---|---|---|
With polarizing filters | Long sensing range | ||||||
Model No. | NX5-PRVM5A | NX5-PRVM5B | NX5-RM7A | NX5-RM7B | NX5-D700A | NX5-D700B | |
Regulatory compliance | ・Low Voltage Directive : EN IEC 60947-5-2 ・EMC Directive : EN IEC 60947-5-2 ・RoHS Directive ・GB/T 14048.10 |
||||||
Sensing range | 0.1 to 5 m 0.328 to 16.404 ft (Note 2) |
0.1 to 7 m 0.328 to 22.966 ft (Note 2) |
700 mm 27.559 in (Note 3) |
||||
Sensing object | φ50 mm φ1.969 in or more opaque, translucent or specular object (Note 2, 4) |
φ50 mm φ1.969 in or more opaque or translucent object (Note 2, 4) |
Opaque, translucent or transparent object (Note 4) |
||||
Hysteresis | - | 15 % or less of operation distance (Note 3) |
|||||
Repeatability (perpendicular to sensing axis) |
0.2 mm 0.008 in or less | 0.3 mm 0.012 in or less | |||||
Supply voltage | 24 to 240 V AC +10–15 % or 12 to 240 V DC +10–15 % Ripple P-P 10 % or less | ||||||
Power consumption | 2 VA or less | ||||||
Output | Relay contact 1 c • Switching capacity: 250 V AC 1 A (resistive load) 30 V DC 2 A (resistive load) • Electrical life: 500,000 or more switching operations (switching frequency 3,600 operations/hour) 100,000 or more switching operations (switching frequency 3,600 operations/hour) • Mechanical life: 100 million or more switching operations (switching frequency 36,000 operations/hour) |
||||||
Output operation | Light-ON | Dark-ON | Light-ON | Dark-ON | Light-ON | Dark-ON | |
Response time | 10 ms or less | ||||||
Operation indicator | Red LED (lights up when the output is ON) | ||||||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) |
||||||
Power indicator | - | ||||||
Sensitivity adjuster | Continuously variable adjuster | - | Continuously variable adjuster | ||||
Automatic interference prevention function |
Incorporated (Two units of sensors can be mounted close together.) | ||||||
Pollution degree | 3 (Industrial environment) | ||||||
Protection | IP66 (IEC) | ||||||
Ambient temperature | –20 to +55 ℃ –4 to +131 ℉ (No dew condensation or icing allowed) (Note 5), Storage: –30 to +70 ℃ –22 to +158 ℉ |
||||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||||
Ambient illuminance | Incandescent light: 3,500 Lx at the light-receiving face | ||||||
Voltage withstandability | 1,500 V AC for one min. between all supply terminals connected together and enclosure, 1,500 V AC for one min. between power supply and output terminals, 1,000 V AC for one min. between relay contact terminals |
||||||
Insulation resistance | 20 MΩ, or more, with 500 V DC megger between power supply and output terminals, and between relay contact terminals | ||||||
Vibration resistance | 10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each | ||||||
Shock resistance | 500 m/s2 (50 G approx.) in X, Y and Z directions for three times each | ||||||
Emitting element | Red LED (modulated) | Infrared LED (modulated) | |||||
Peak emission wavelength |
660 nm 0.026 mil | 880 nm 0.035 mil | |||||
Material | Enclosure: Polycarbonate, Lens: Polycarbonate, Cover: Polycarbonate, Front cover (retroreflective type sensor only) : Acrylic | ||||||
Cable | 0.3 mm2 5-core (thru-beam type emitter: 2-core) cabtyre cable, 2 m 6.562 ft long | ||||||
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable (thru-beam type: both emitter and receiver). | ||||||
Net weight | 140 g approx. | ||||||
Accessories | RF-230 (Reflector): 1 pc. Adjusting screwdriver: 1 pc. |
RF-230 (Reflector): 1 pc. | Adjusting screwdriver: 1 pc. |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2) | The sensing range and the sensing object of the retroreflective type sensor is specified for the RF-230 reflector. Further, the sensing range is the possible setting range for the reflector. The sensor can detect an object less than 0.1 m 0.328 ft away. |
3) | The sensing range and the hysteresis of the diffuse reflective type sensor are specified for white non-glossy paper (200 x 200 mm 7.874 x 7.874 in) as the object. |
4) | Make sure to confirm detection with an actual sensor before use. |
5) | In case the sensor is to be used at an ambient temperature of –15 ℃ +5 ℉, or less, please contact our office. |
Type | Retroreflective | Diffuse reflective | ||||
---|---|---|---|---|---|---|
With polarizing filters | Long sensing range | |||||
Model No. | NX5-PRVM5A | NX5-PRVM5B | NX5-RM7A | NX5-RM7B | NX5-D700A | NX5-D700B |
Utilization category | AC-12/DC-12 | |||||
Impulse withstand voltage | 2.5kV | |||||
Output minimum operational current | DC5V 1mA or more | |||||
Turn on time / Turn off time (Note 4) | 10ms / 10ms | |||||
Maximum response frequency (Note 5) | 50Hz | |||||
Pollution degree | 3 (Industrial environment) | |||||
Class of protection against electric shock | Out of classification | |||||
Excess gain | 10% (Note 6) | 10% | 14% (Note 6) |
Note:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2) | The output applied voltage should be the same as the supply voltage of the sensor. |
3) | Be sure to add a short-circuit protection (a fuse or a breaker) to the power supply input and the output. In addition, use 3A or less fast blow fuse or breaker. |
4) | Turn-On time and Turn-OFF time are the delay time between reference sensor and measurement sensor in case round plate rotates as below. |
5) | The maximum response frequency is the value calculated below. Maximum response frequency = 1 / (Turn on time+Turn off time) |
6) | Excess gain of NX5-PRVM5□/NX-D700□ is the value in case sensitivity aduster is in maximum position. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)