Compact Inductive Proximity Sensor GA-311/GH

Cautions For Use

  • Never use this product as a sensing device for personnel protection.
  • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country.
Always be sure to use sensor heads and amplifiers from the same set.
Do not shorten or lengthen the sensor head cable.

Mounting of the sensor head

How to mount the sensor head

  • The tightening torque should be as given below. Make sure to use a set screw with a cup-point end.
Mounting of the sensor head How to mount the sensor head      
Model No. Tightening torque A (mm in)
GH-2SE 0.17N·m 3 0.118 or more
GH-3SE 0.17N·m 4 0.157 or more
GH-5SE 0.78N·m 5 0.197 or more
GH-8SE
GH-F8SE
0.59N·m 5 0.197 or more
Note: Do not tighten excessively.

Distance from surrounding metal

  • If there is a metal near the sensor head, it may affect the sensing performance.
    Keep the minimum distance specified in the table below.
Mounting of the sensor head Distance from surrounding metal      
Model No. B (mm in)
GH-2SE 3 0.118
GH-3SE 4 0.157
GH-5SE 5 0.197
GH-8SE
GH-F8SE
9 0.354

Mutual interference

  • When two or more sensors are installed in parallel or face to face, keep the minimum separation distance specified below to avoid mutual interference.

<Face to face mounting>

Mounting of the sensor head Mutual interference Face to face mounting

<Parallel mounting>

Mounting of the sensor head Mutual interference Parallel mounting
     
Model No. C (mm in) D (mm in)
GH-2SE 15 0.591 10 0.394
GH-3SE 20 0.787 15 0.591
GH-5SE 25 0.984 20 0.787
GH-8SE
GH-F8SE
40 1.575 26 1.024

Sensing range

  • The sensing range is specified for the standard sensing object. With a non-ferrous metal, the sensing range is obtained by multiplying with the correction coefficient specified below. Further, the sensing range also changes if the sensing object is smaller than the standard sensing object or if the sensing object is plated.

Correction coefficient

  GH-2SE GH-3SE GH-5SE GH-8SE
GH-F8SE
Iron 1 1 1 1
Stainless steel (SUS304) 0.68 approx. 0.55 approx. 0.69 approx. 0.64 approx.
Brass 0.53 approx. 0.35 approx. 0.41 approx. 0.37 approx.
Aluminum 0.51 approx. 0.33 approx. 0.39 approx. 0.32 approx.

Others

  • Do not use during the initial transient time (0.5 sec.) after the power supply is switched on.
  • Do not use the sensor at places having intense vibrations, as this can cause malfunction.
  • Make sure that stress by forcible bend or pulling is not applied directly to the cable joint of the sensor head.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)