Designation | Enable grip switch | ||||||||
---|---|---|---|---|---|---|---|---|---|
Series | SG-C1 series | ||||||||
Applicable standards |
IEC 60947-5-1, EN 60947-5-1, EN 60947-5-8, JIS C 8201-5-1, GS-ET-22, UL 508, CSA C22.2 No.14 | ||||||||
Standards for use |
ISO 12100 / EN ISO 12100, IEC 60204-1 / EN 60204-1, ISO 11161 / EN ISO11161, ISO 10218-1 / EN ISO 10218-1, ANSI/RIA/ISO 10218-1, ANSI/RIA R15.06, ANSI B11.19, ISO 13849-1:2015 / EN ISO 13849-1:2015 | ||||||||
Applicable regulations |
CE Marking [Machinery Directive (2006/42/EC), RoSH Directive] UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoSH Regulations] |
||||||||
Operating condition |
Ambient temperature |
-25 to +60 ℃ -13 to +140 ℉ (No dew condensation or icing allowed) Storage: -40 to +80 ℃ -40 to +176 ℉ |
|||||||
Ambient humidity | 45 to 85 % RH | ||||||||
Pollution degree | 3 (Inside 2) | ||||||||
Altitude | 2,000 m 6,561.68 ft max. | ||||||||
Impulse withstand voltage (Uimp) |
2.5 kV (Momentary pushbutton switch and key selector switch: 1.5 kV) | ||||||||
Rated insulation voltage (Ui) |
250 V (Momentary pushbutton switch and key selector switch: 125 V) / Models with indicator: 30 V |
||||||||
Thermal current (Ith) | 3 A (Emergency stop switch: 5 A) | ||||||||
Rated operational voltage (Ue) / Rated operational current (Ie) (Note) |
Ue | ||||||||
30V | 125V | 250V | |||||||
Ie | Grip switch |
3 position enabling switch (Terminal No.: NO1-C1, NO2-C2) |
AC | Resistive load (AC-12) | - | 1A | 0.5A | ||
Inductive load (AC-15) | - | 0.7A | 0.5A | ||||||
DC | Resistive load (DC-12) | 1A | 0.2A | - | |||||
Inductive load (DC-13) | 0.7A | 0.1A | - | ||||||
Push monitor switch (Terminal No. 31-32) |
AC | Resistive load (AC-12) | - | 2.5A | 1.5A | ||||
Inductive load (AC-15) | - | 1.5A | 0.75A | ||||||
DC | Resistive load (DC-12) | 2.5A | 1.1A | 0.55A | |||||
Inductive load (DC-13) | 2.3A | 0.55A | 0.27A | ||||||
Emergency stop switch (Terminal No. 1-2, 1-2) |
AC | Resistive load (AC-12) | - | 5A | 3A | ||||
Inductive load (AC-15) | - | 3A | 1.5A | ||||||
DC | Resistive load (DC-12) | 2A | 0.4A | 0.2A | |||||
Inductive load (DC-13) | 1A | 0.22A | 0.1A | ||||||
Momentary pushbutton switch / Key selector switch (Terminal No. C1-NO1, NC1 C2-NO2, NC2 ) |
AC | Resistive load (AC-12) | - | 0.5A | - | ||||
Inductive load (AC-15) | - | 0.3A | - | ||||||
DC | Resistive load (DC-12) | 1A | 0.2A | - | |||||
Inductive load (DC-13) | 0.7A | 0.1A | - | ||||||
Electric shock protection class |
Class II (IEC 61140), 回(double insulated) (Models with indicator: Class III) |
||||||||
Operating frequency | 1,200 operations/hour | ||||||||
B10d | 2,000,000 (ISO 13849-1 Annex C Table C.1) |
||||||||
Mechanical durability |
Position 1→2→1: 1,000,000 operations min. Position 1→2→3→1: 100,000 operations min. |
||||||||
Electrical durability |
100,000 operations min. (Rated operating load) 1,000,000 operations min. (AC / DC 24 V 100 mA) |
||||||||
Shock resistance | Malfunction: 150 m/s2, Destruction: 1,000 m/s2 | ||||||||
Free fall | 1.0 m 3.281 ft 1 time (Based on IEC60068-2-32) | ||||||||
Vibration resistance |
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 16.7 Hz, half amplitude 1.5 mm 0.059 in |
||||||||
Protection | IP66 / IP67 | Without additional switch and pilot light | |||||||
IP65 | With additional switch and/or pilot light | ||||||||
Conditional short-circuit current |
50 A (250 V) | ||||||||
Short-circuit protective device |
250 V AC, 10 A Fuse (IEC60127-1) | ||||||||
Direct opening force | 60 N min. (Push monitor switch) | ||||||||
Direct opening travel | 4.7 mm 0.185 in min. (Push monitor switch) | ||||||||
Actuator Strength (Entire button is pushed) |
500 N min. (Grip switch) | ||||||||
Indicator (Note) | Green LED Rated Operating Voltage: DC 24 V ±10 % Rated current: 15 mA |
||||||||
Weight | SG-C1-21: Approx. 140 g SG-C1-21-E: Approx. 150 g SG-C1-21-EG: Approx. 155 g SG-C1-21-MM: Approx. 155 g SG-C1-21-EMM: Approx. 165 g SG-C1-21-EMK: Approx. 170 g |
Note: | As for the type with pilot light, Ue (contact ratings) of all switches is only less than 30 V DC, and connect all switches to SELV (safety extra low voltage) or PELV (protective extra low voltage) circuit. |
---|
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)