Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Key selector switch SG-D1(Discontinued Products) > Specifications
We are sorry, the products have been discontinued. Please refer to the details of the discontinued products and the recommended substitutes list below.
|
Model No. | Position | Contact configuration |
Contact block | Operation position | Key removal Mounting position |
||
---|---|---|---|---|---|---|---|
Mounting position (Note) |
Contact | 1 | 2 | ||||
SG-D1-2A11 | 1NO/1NC (11) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
SG-D1-2A22 | 2NO/2NC (22) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
[3] | NO | ● | |||||
[4] | NC | ● | |||||
SG-D1-2B11 | 1NO/1NC (11) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
SG-D1-2B22 | 2NO/2NC (22) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
[3] | NO | ● | |||||
[4] | NC | ● | |||||
SG-D1-2C11 | 1NO/1NC (11) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
SG-D1-2C22 | 2NO/2NC (22) |
[1] | NO | ● | |||
[2] | NC | ● | |||||
[3] | NO | ● | |||||
[4] | NC | ● |
Note: | Contact blocks are attached as shown below: |
---|
Designation | Key selector switch | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Series | SG-D1 series | |||||||||
Applicable standards |
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1, UL 508 (UL listed Certification), CSA 22.2 No.14 (c-UL listed Certification) | |||||||||
Operating condition | Ambient temperature |
-25 to +60℃ -13 to + 140 ℉ (No dew condensation or icing allowed) Storage: -40 to +80 ℃ -40 to +176 ℉ |
||||||||
Ambient humidity | 45 to 85 % RH | |||||||||
Pollution degree | 3 | |||||||||
Altitude | 2,000 m 6,561.68 ft max. | |||||||||
Impulse withstand voltage (Uimp) |
4 kV | |||||||||
Rated insulation voltage (Ui) |
600 V | |||||||||
Thermal current (Ith) | 10 A | |||||||||
Rated operational voltage (Ue) / Rated operational current (Ie) |
Ue | |||||||||
24V | 48V | 50V | 110V | 220V | 440V | |||||
Ie | AC | Resistive load (AC-12) |
10A | - | 10A | 10A | 6A | 2A | ||
Inductive load (AC-15) (A600)) |
10A | - | 7A | 5A | 3A | 1A | ||||
DC | Resistive load (DC-12) |
8A | 4A | - | 2.2A | 1.1A | - | |||
Inductive load (DC-13) (P600) |
4A | 2A | - | 1.1A | 0.6A | - | ||||
Contact resistance |
50 mΩ max. (initial value) | |||||||||
Insulation resistance |
100 MΩ min. (500 V DC megger) | |||||||||
Electric shock protection class |
Class II(IEC 61140) | |||||||||
Overvoltage category |
II(IEC 60664-1) | |||||||||
Protection | Front of the panel: IP65 | |||||||||
Shock resistance | Malfunction: 100 m/s2, Destruction: 1,000m/s2 | |||||||||
Vibration resistance |
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in |
|||||||||
B10d | 100,000 (ISO 13849-1 Annex C Table C.1) |
|||||||||
Mechanical durability |
100,000 operations min. | |||||||||
Electrical durability |
100,000 operations min. (1,200 operations/hour) | |||||||||
Material | Actuator: PA6, Contact block: PA66 | |||||||||
Connecting method |
Terminal screw (M3.5 philips & flathead ) | |||||||||
Applicable wire size |
Max.2mm2(Single core ø1.6 ø0.063 max.) 2 wires max. |
|||||||||
Tightening torque of the terminal screws |
1.0 to 1.3 N・m | |||||||||
Tightening torque of the locking ring |
2.0 N・m | |||||||||
Selector behavior | 2 positions | |||||||||
Minimum direct opening operating angle |
90° | |||||||||
Minimum direct opening torque |
0.4 N・m | |||||||||
Maximum operation angle |
90° | |||||||||
Weight | SG-D1-2□11: Approx. 75 g, SG-D1-2□22:Approx. 95 g | |||||||||
Accessories | Key: 2pcs., Lever lock: 1 pc. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)