Type | Compact fan type | |
---|---|---|
Model No. | ER-Q | |
CE marking directive compliance | EMC Directive, RoHS Directive | |
Charge removal time (±1,000 V → ±100 V) |
1.5 sec. approx. (Note 2) | |
Ion balance | ±10 V or less (Note 2) | |
Power supply voltage | 24 V DC ±10% | |
Power consumption | 200 mA or less | |
Discharge method | High-frequency AC method | |
Discharge output voltage | ±2 kV approx. | |
Max. fan speed | 6.4 m/s (Note 2) | |
Max. fan volume | 0.2 m3/min. | |
Output(CHECK, ALARM) | NPN transistor / open collector • Max sink current: 50 mA • Applied voltage: 30 V DC or less (between output terminal and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) |
|
Output operation | Check: On when discharge check (Note 3) detected Off at all other times Error: Off when discharge error or fan error (Note 3) detected On at all other times |
|
Short-circuit protection | Incorporated | |
Indicators | Discharge (DSC): Green LED, Alarm (ALARM): Red LED | |
Ozone generation amount | 0.02 ppm or less (Note 2) | |
Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ℉ | |
Ambient humidity | 35 to 65% RH (No dew condensation allowed), Storage: 35 to 65% RH | |
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | |
Grounding method | C (capacitor) grounding | |
Material | Enclosure: PBT, Discharge needle: Tungsten | |
Weight | Net weight: 110 g approx. | |
Accessory | Connector for wiring: 1 set [Manufactured by Molex: Housing (5557-08P), Terminal (5556T)] |
Notes:
1) | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉. |
---|---|
2) | Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed. |
3) | Discharge check: Drop in discharging status detected. Discharge error: Abnormal discharge detected. Fan error: Fan operating problem detected. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)