AUTOMATION
CONTROLS

Search
Discontinued
Products



Compact Fan Type Ionizer ER-Q (Discontinued Products)

Specifications

Type Compact fan type
Model No. ER-Q
CE marking directive compliance EMC Directive, RoHS Directive
Charge removal time
(±1,000 V → ±100 V)
1.5 sec. approx. (Note 2)
Ion balance ±10 V or less (Note 2)
Power supply voltage 24 V DC ±10%
Power consumption 200 mA or less
Discharge method High-frequency AC method
Discharge output voltage ±2 kV approx.
Max. fan speed 6.4 m/s (Note 2)
Max. fan volume 0.2 m3/min.
Output(CHECK, ALARM) NPN transistor / open collector
• Max sink current: 50 mA
• Applied voltage: 30 V DC or less (between output terminal and 0 V)
• Residual voltage: 1 V or less (at 50 mA sink current)
  Output operation Check: On when discharge check (Note 3) detected
Off at all other times
Error: Off when discharge error or fan error (Note 3) detected
On at all other times
  Short-circuit protection Incorporated
Indicators Discharge (DSC): Green LED, Alarm (ALARM): Red LED
Ozone generation amount 0.02 ppm or less (Note 2)
Ambient temperature 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: –10 to +65 ℃ +14 to +149 ℉
Ambient humidity 35 to 65% RH (No dew condensation allowed), Storage: 35 to 65% RH
Vibration resistance 10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each
Grounding method C (capacitor) grounding
Material Enclosure: PBT, Discharge needle: Tungsten
Weight Net weight: 110 g approx.
Accessory Connector for wiring: 1 set
[Manufactured by Molex: Housing (5557-08P), Terminal (5556T)]

Notes:

1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
2) Typical value at 100 mm 3.937 in from directly in front of air outlet, fan speed MAX., with no filter installed.
3) Discharge check: Drop in discharging status detected. Discharge error: Abnormal discharge detected. Fan error: Fan operating problem detected.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)