AUTOMATION
CONTROLS

Search
Discontinued
Products



AVT3/AVL3 (FS-T) Switches

1.P/C board terminal

Pin plunger

Pin plunger

External dimensions

General tolerance: ±0.25

Pin plunger
P/C board pattern
Pin plunger
Pretravel (PT) Max. 0.6mm
Movement Differential (MD) Max. 0.1mm
Overtravel (OT) Min. 0.4mm
Operating Position (OP) Distance from mounting hole 8.4±0.3mm
Distance from stand-off 11.7±0.4mm

Short hinge lever

Short hinge lever

External dimensions

General tolerance: ±0.25

Short hinge lever
Pretravel (PT) Max. 2.5mm
Movement Differential (MD) Max. 0.5mm
Overtravel (OT) Min. 0.8mm
Operating Position (OP) Distance from mounting hole 8.8±0.8mm
Distance from stand-off 12.1±0.9mm

Hinge lever

Hinge lever

External dimensions

General tolerance: ±0.25

Hinge lever
Pretravel (PT) Max. 2.8mm
Movement Differential (MD) Max. 0.8mm
Overtravel (OT) Min. 1.2mm
Operating< Position (OP) Distance from mounting hole 8.8±0.8mm
Distance from stand-off 12.1±0.9mm

Long hinge lever

Long hinge lever

External dimensions

General tolerance: ±0.25

Long hinge lever
Pretravel (PT) Max. 3.5mm
Movement Differential (MD) Max. 1.0mm
Overtravel (OT) Min. 1.6mm
Operating Position (OP) Distance from mounting hole 8.8±1.2mm
Distance from stand-off 12.1±1.3mm

Simulated roller lever

Simulated roller lever

External dimensions

General tolerance: ±0.25

Simulated roller lever
Pretravel (PT) Max. 2.8mm
Movement Differential (MD) Max. 0.8mm
Overtravel (OT) Min. 1.2mm
Operating Position (OP) Distance from mounting hole 11.65±0.8mm
Distance from stand-off 14.95±0.9mm

Roller lever

Roller lever

External dimensions

General tolerance: ±0.25

Roller lever
Pretravel (PT) Max. 2.5mm
Movement Differential (MD) Max. 0.5mm
Overtravel (OT) Min. 0.8mm
Operating Position (OP) Distance from mounting hole 14.5±0.8mm
Distance from stand-off 17.8±0.9mm
CAD Data List

Return to top

2.Solder terminal

Solder terminal

External dimensions

General tolerance: ±0.25

Solder terminal
*As for the dimensions of lever types, dimensions other than terminals are same as P/C board terminal.
CAD Data List

Return to top

3. .110 quick-connect terminal

.110 quick-connect terminal

External dimensions

General tolerance: ±0.25

.110 quick-connect terminal
*As for the dimensions of lever types, dimensions other than terminals are same as P/C board terminal.
CAD Data List

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)