Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Timers / Counters / FA Componets > Counters > LC4H-W Electronic Counters(DIN 48) > Rating/ Performance
Discontinuation plan
|
|
Item | Ralay output type | Transistor output type | ||||
---|---|---|---|---|---|---|
AC type | DC type | AC type | DC type | |||
Rating | Rated operating voltage | 100 to 240 V AC 24 V AC | 12 to 24 V DC | 100 to 240 V AC 24 V AC | 12 to 24 V DC | |
Rated frequency | 50/60 Hz common | - | 50/60 Hz common | - | ||
Power consumption | Max. 10 V A | Max. 3 W | Max. 10 V A | Max. 3 W | ||
Rated control capacity | 3 A, 250 V AC (resistive load) | 100 mA, 30 V DC | ||||
Input mode | Addition (UP)/Subtraction (DOWN)/Direction (DIR)/Individuality (IND)/Phase (PHASE) 5 modes selectable by DIP switch | |||||
Counting speed | 30 Hz(cps)/5 KHz(cps) (selectable by DIP switch) | |||||
Counting input (Input 1, 2) | Min. input signal width: 16.7 ms at 30 Hz(cps)/0.1 ms at 5 KHz(cps) ON time: OFF time = 1:1 | |||||
Reset input method | Min. input signal width: 1 ms, 20 ms (selected by DIP switch) | |||||
Input signal | Contact or Open collector input/Input impedance: 1 kΩ or less, Input residual voltage: 2 V or less, Open impedance: 100 kΩ or less, Max. energized voltage: 40 V DC | |||||
Output mode | Output 1. HOLD-B, C, D SHOT-A (4 modes) Output 2. HOLD-A, B, C SHOT-A, B, C, D (8 modes) (selectable by DIP switch) |
|||||
One shot output time | Approx. 1 s | |||||
Indication | 7-segment LCD, Counter value (backlight red LED), Setting value (backlight yellow LED) | |||||
Digit | -99999 to 999999 (-5 digits to 6 digits) (0 to 999999 for setting) | |||||
Memory | EEP-ROM (Overwriting times: 105ope. or more) | |||||
Contact | Contact arrangement | 1 Form A + 1 Form A | 1 Form A + 1 Form A (Open collector) | |||
Contact resistance (Intial value) | 100 mΩ (at 1 A 6 V DC) | - | ||||
Contact material | Ag alloy/Au flush | - | ||||
Life | Mechanical(contact) | Min. 2.0×107ope. | - | |||
Electrical(contact) | Min. 1.0×105ope. (At rated control voltage) | Min. 1.0×107ope. (At rated control voltage) | ||||
Electrical | Allowable operating voltage range | 85 to 110 % of rated operating voltage | ||||
Break down voltage (Initial value) |
Between live and dead metal parts: 2, 000 Vrms for 1 min (pin type) Between input and output: 2, 000 Vrms for 1 min Between open contacts: 1, 000 Vrms for 1 min |
Between live and dead metal parts: 2, 000 Vrms for 1 min Between input and output: 2, 000 V AC for 1 min |
||||
Insulation resistance (At 500 V DC) (Initial value) | Between live and dead metal parts: Min. 100 MΩ (pin type) Between input and output: Min. 100 MΩ Between open contact: Min. 100 MΩ |
Between live and dead metal parts: Min. 100 MΩ (pin type) Between input and output: Min. 100 MΩ |
||||
Temperature rise | Max. 65°C (under the flow of nominal operating current at nominal voltage) |
- |
||||
Mechanical | Vibration resistance | Functional | 10 to 55 Hz (1 cycle/min), single amplitude: 0.35 mm .014 inch (10 min on 3 axes) | |||
Destructive | 10 to 55 Hz (1 cycle/min), single amplitude: 0.75 mm .030 inch (1 h on 3 axes) | |||||
Shock resistance | Functional | Min. 98 m/s2 321.522 ft./s2(4 times on 3 axes) | ||||
Destructive | Min. 294 m/s2 964.567 ft./s2(5 times on 3 axes) | |||||
Operating conditions | Ambient temperature | -10°C to 55°C/ +14 ° F to +131 ° F | ||||
Ambient humidity | Max. 85 % RH (non-condensing) | |||||
Air pressure | 860 to 1, 060 h Pa | |||||
Ripple rate | - |
20 % or less | - |
20 % or less | ||
Connection | 11-pin/screw terminal | |||||
Protective construction | IP66 (front panel with a rubber gasket) |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)