Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Timers / Counters / FA Componets > Temperature Controllers > KT2 Temperature Controllers > Cautions For Use
Discontinuation plan
|
Please install vertically in order to satisfy the IP66 specification for dust and splash proofing.
The possible control panel plate thickness for installation is between 1 to 10 mm 0.039 to 0.394 in.
(1) | Insert the unit from the front of the control panel. |
---|---|
(2) | Insert the mounting frame until that the two edges make contact with the panel. |
(3) | Tighten the screw and then turn it 3/4 of a turn after the edge of the screw reaches the panel. |
|
(1)PV/SV display (Red) | : | Indicates the process value (PV) and setting value (SV). |
---|---|---|
(2)MEMO/STEP display (Green) | : | Indicates the memory number during fixed value control. Indicates step number during program control. |
(3)PV indicator (Red) | : | Lights up when the input value is indicated. |
(4)SV indicator (Green) | : | Lights up when main setting value is indicated. |
(5)AT indicator (Yellow) | : | Flashes during auto-tuning (AT). |
(6)T/R indicator (Yellow) | : | Flashes during serial communication (Lit while sending data, Unlit while receiving data). |
(7)OUT indicator (Green) | : | Lights up when control output or OUT1 (heating side) output (optional: heating / cooling control) is ON. For DC current output type, it flashes corresponding to the manipulated variable in a 0.25 second cycle. |
(8)EV1 indicator (Red) | : | Lights up when alarm output 1 or OUT2 (cooling side) output (optional: heating / cooling control) is ON. |
(9)EV2 indicator (Red) | : | Lights up when alarm output 2 is ON. |
(10)Increase key | : | Increases the numeric value. |
(11)Decrease key | : | Decreases the numeric value. |
(12)Mode key | : | Selects the setting mode or registers the setting value. |
(13)OUT/OFF key | : | The control output OUT / OFF or program control RUN / STOP can be switched. |
This controller is intended to be used in the following environment (IEC 61010-1)
Mount the controller in a place with:
Wire-pressed terminal |
Company name | Type name | Fastening torque |
---|---|---|---|
Fork type | NICHIFU Co., Ltd. | 1.25Y-3 | 0.6 N•m Max. 1.0 N•m. |
J.S.T. Mfg. Co., Ltd. | VD1.25-B3A | ||
Round type | NICHIFU Co., Ltd. | 1.25-3 | |
J.S.T. Mfg. Co., Ltd. | V1.25-3 |