KW8M Eco-POWER METER (Discontinued Products)

Lineup with new energy saving and environmentally friendly features!

AKW8111
AKW8111
AKW8111H
AKW8111H
AKW8115
AKW8115

Recommended Substitutes

Discontinued product Recommended substitute
Product number/Part number Last time buy   Product number/Part number Product name Remark
Product number: AKW8111
Part number: AKW8111
September 30, 2021
To be discontinued
Product number: AKW1111B
Part number: AKW1111B
KW1M Eco-Power Meter Substitute product has different shapes and functions and it may not completely compatible.
Please contact us for more details.
Product number: AKW8111H
Part number: AKW8111H
September 30, 2021
To be discontinued
Product number: AKW1111B
Part number: AKW1111B
KW1M Eco-Power Meter Substitute product has different shapes and functions and it may not completely compatible.
Please contact us for more details.
Product number: AKW8115
Part number: AKW8115
September 30, 2021
To be discontinued
Product number:-
Part number:-
KW9M Eco-Power Meter Suggested alternative products may be different under the conditions of use.
Substitute product has different shapes and functions and it may not completely compatible.
Please contact us for more details.

Recommended Substitutes for Accessories/Options

Discontinued product Recommended substitute
Product name Product number/Part number Last time buy   Product number/Part number Product name Remark
Terminal protective cover Product number: AKT8801
Part number: AKT8801
September 30, 2021 Product number:-
Part number:-
- Sorry, no suggested alternative products.
Through type Current Transformer (CT) Product number: AKW4506C
Part number: AKW4506C
December 28, 2016 Product number: AKW4506B
Part number: AKW4506B
Through type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
Through type Current Transformer (CT) Product number: AKW4507C
Part number: AKW4507C
December 28, 2016 Product number: AKW4507B
Part number: AKW4507B
Through type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
Clamp-on type Current Transformer (CT) Product number: AKW4801C
Part number: AKW4801C
December 28, 2016 Product number: AKW4801B
Part number: AKW4801B
Clamp-on type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
Clamp-on type Current Transformer (CT) Product number: AKW4802C
Part number: AKW4802C
December 28, 2016 Product number: AKW4802B
Part number: AKW4802B
Clamp-on type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
Clamp-on type Current Transformer (CT) Product number: AKW4803C
Part number: AKW4803C
December 28, 2016 Product number: AKW4803B
Part number: AKW4803B
Clamp-on type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
Clamp-on type Current Transformer (CT) Product number: AKW4804C
Part number: AKW4804C
December 28, 2016 Product number: AKW4804B
Part number: AKW4804B
Clamp-on type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
Clamp-on type Current Transformer (CT) Product number: AKW4808C
Part number: AKW4808C
December 28, 2016 Product number: AKW4808B
Part number: AKW4808B
Clamp-on type Current Transformer (CT) Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
CT trunk cable Product number: AKW4811
Part number: AKW4811
December 28, 2016 Product number: AKW4811B
Part number: AKW4811B
CT trunk cable Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes

[Note]
The following applicable products and options are available continuously.

Please refer to detail description of each option for applicable models.


1.OPTIONS

Extension cable

Extension cable
Product name Model No.
CT extension cable
As an Eco-POWER METER dedicated CT option
3 m 9.843 ft AKW4703
5 m 16.404 ft AKW4705
10 m 32.808 ft
(made-to-order)
AKW4710
*1 Specify no more than one level for various extension cable connections.
*2 15 m 49.213 ft and 20 m 65.617 ft extension cables are available on a made-to-order basis. For details, please contact our company.

Intermediate power cable

Intermediate power cable
Product name Model No.
Intermediate power cable AKE2811
*1 Use of an intermediate power cable is recommended when the dedicated CT attachment power cable is not divided into two.

Relay cable

Product name Model No.
Relay cable (1m 3.281 ft) (made-to-order) AKW4811B
*1 A relay cable comes with each dedicated current transformer (CT) for free.

Required for DIN rail mounting

Mounting rails (applicable for DIN and IEC standards):
For KW4M pin type (AKW5211 and AKW5212), KW7M, KW2G / KW2G-H, KW1M / KW1M-H, KW2M
Model No.:ATA48011

Mounting rails (applicable for DIN and IEC standards)

Fastening plate:
For KW4M pin type (AKW5211 and AKW5212), KW7M, KW2G / KW2G-H, KW1M / KW1M-H, KW2M
Model No.:ATA4806

Fastening plate

DIN rail terminal socket:
For KW4M 11-pin type (AKW5211 and AKW5212)
Model No.:ATC180041

DIN rail terminal socket

Required for panel mounting

Rear terminal socket:
For KW4M 11-pin type (AKW5211 and AKW5212)
Model No.:AT78051

Rear terminal socket

11P cap:
Applicable to KW4M 11 pin type (AKW5211, AKW5212)
Model No.:ATA4861
標準価格<税別>:165円

11P cap

Mounting frame:
For KW1M and KW1M-H * Sold separately
Model No.:AKW1822

Mounting frame

Rubber packing, attachment frame:
For KW4M
[Attachment frame] Model No.:ATA4811
[Rubber packing] Model No.:ATC18002

Rubber packing, attachment frame

Convenient for panel mounting

Protective cover for DIN 48 size (flexible type) :
For KW4M
Model No.:AQM4803

Protective cover for DIN 48 size (flexible type)

Terminal protective cover:
For KW4M screw terminal type (AKW5111 and AKW5112)
Model No.:AKW4823

Terminal protective cover

Mounting frame:
For KW4M * For fixing
Model No.:AKW4822

Mounting frame

Mounting frame:
For KW8M
Model No.:AKW8822

Mounting frame

Others

Product name Descriptions Model No.
Screwdriver for terminal socket Screwdriver for terminal socket For KW7M, DLL AFP0806
Backup battery Backup battery For KW1M-H, KW2G-H main unit, ELC□, DLL AFPG804
Backup battery Backup battery For with logging function type KW8M (AKW8111H) only AFC8801

Return to top

2.DEDICATED CURRENT TRANSFORMER (CT)

* Dedicated current transformers (CT) are dedicated for low voltage under 440 V AC system. They can not be used for high voltage circuit.
* In each type of Eco-POWER METER excluding KW2M, KW9M and AKW8115, a combination of secondary side 5 A CTs and dedicated CTs for 5 A (AKW4801B) is used for measuring high voltage circuits; therefore, AKW4801B is definitely necessary. For details, confirm with each respective user's manual.
* Since dedicated CTs (AKW48***) cannot be used when measuring with KW2M, KW9M and AKW8115, please be careful not to purchase a dedicated CT by mistake.
* For the KW2M, KW9M and AKW8115, current transformers manufactured by U.R.D. Co., Ltd. (clamp-on type CT CTL-CL series) are recommended. Please confirm the specification beforehand.
* Dedicated current transformers (CT) are not included in Eco-POWER METERs.
* Each dedicated current transformer (CT) includes a 1 m 3.28 ft relay cable, respectively.

Order guide

Primary side rated current Model No.
Clamp-on type 5A/50A AKW4801B
100A AKW4802B
250A AKW4803B
400A AKW4804B
600A AKW4808B
Through type 50A/100A AKW4506B
250A/400A AKW4507B
600A AKW4508B

Notes:

1)

Be sure to place an order according to distribution systems
excluding AKW8115, KW9M and KW2M.

Discontinued Products

Discontinued Products Recommended Products
Product Name Model No./Part number Last time buy   Model No./Part number Remark
CT Clamp-on type 5A/50A Model number : AKW4801C
Part number : AKW4801C
December 28, 2016 Model number : AKW4801B
Part number : AKW4801B
Please refer to following :
>>Important Notice about Discontinued Products and Recommended Substitutes
CT Clamp-on type 100A Model number : AKW4802C
Part number : AKW4802C
December 28, 2016 Model number : AKW4802B
Part number : AKW4802B
CT Clamp-on type 250A Model number : AKW4803C
Part number : AKW4803C
December 28, 2016 Model number : AKW4803B
Part number : AKW4803B
CT Clamp-on type 400A Model number : AKW4804C
Part number : AKW4804C
December 28, 2016 Model number : AKW4804B
Part number : AKW4804B
CT Clamp-on type 600A Model number : AKW4808C
Part number : AKW4808C
December 28, 2016 Model number : AKW4808B
Part number : AKW4808B
CT Through type 50A/100A Model number : AKW4506C
Part number : AKW4506C
December 28, 2016 Model number : AKW4506B
Part number : AKW4506B
CT Through type 250A/400A Model number : AKW4507C
Part number : AKW4507C
December 28, 2016 Model number : AKW4507B
Part number : AKW4507B
CT Through type 600A Model number : AKW4508C
Part number : AKW4508C
December 28, 2016 Model number : AKW4508B
Part number : AKW4508B
Note : You cannot use discontinued dedicated CT and substitute Eco-POWER METER together, or vice versa.

Specifications

Item Clamp-on typ
AKW4801B
AKW4801C
AKW4802B
AKW4802C
AKW4803B
AKW4803C
AKW4804B
AKW4804C
AKW4808B
AKW4808C
CE marking directive compliance Low Voltage Directive, RoHS Directive
Primary side rated current 5A/50A 100A 250A 400A 600A
Secondary side rated current 1.67mA/16.7mA 33.3mA 125mA 200mA 200mA
Winding (Turn) 3000 3000 2000 2000 3000
Ratio error ±2.0%F.S.
Through hole ø10 ø0.39 ø16 ø0.63 ø24 ø0.94 ø36 ø1.42 ø36 ø1.42
Breakdown voltage (initial) 1000V AC/1min
(Between through hole and output lead wire)
2000V AC/1min
(Between through hole and output lead wire)
Insulation resistance (initial) Min. 100 M Ω (at 500 V DC) (Between through hole and output lead wire)
Functional vibration resistance 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes)
Vibration resistance 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes)
Functional shock resistance Min. 98m/s2(4 times on 3 axes)
Shock resistance Min. 294m/s2(5 times on 3 axes)
Output protection level ±7.5 V with clamp element ±3.0V with clamp element
Permissible clamping frequency 100 times approx.
Ambient temperature range -10 to +50℃ +14 to +122 ℉ (without frost and non-condensing)
Storage temperature -20 to +60℃ -4 to +140 ℉ (without frost and non-condensing)
Ambient humidity 35 to 85%RH(at +20℃ +68 ℉ non-condensing)
Dimensions (mm in)
(W x H x D)
23 x 40 x 26.5
0.08 x 0.13 x 0.09
30 x46.5 x 32
0.10 x 0.15 x 0.11
45 x65 x 34
0.15 x 0.21 x 0.11
57 x81 x 38
0.19 x 0.27 x 0.12
62.6 x93.3 x 40
0.21 x 0.31 x 0.13
Weight
(Relay cable included)
60 g approx. 90 g approx. 200 g approx. 295 g approx. 450 g approx.
Item Through type
AKW4506B
AKW4506C
AKW4507B
AKW4507C
AKW4508B
AKW4508C
CE marking directive compliance Low Voltage Directive, RoHS Directive
Primary side rated current 50A/100A 250A/400A 600A
Secondary side rated current 16.7mA/33.3mA 125mA/200mA 200mA
Winding (Turn) 3000 2000 3000
Ratio error ±1.0%F.S.
Through hole ø17mm ø0.67 in ø36mm ø1.42 in
Breakdown voltage (initial) 1000V AC/1min
(Between through hole and output lead wire))
2000V AC/1min
(Between through hole and output lead wire)
Insulation resistance (initial) Min. 100 MΩ (at 500 V DC megger) (Between through hole and output lead wire)
Functional vibration resistance 10 to 55 Hz (1 cycle / min), single amplitude: 0.15 mm 0.01 in (10 min on 3 axes)
Vibration resistance 10 to 55 Hz (1 cycle / min), single amplitude: 0.375 mm 0.01 in (1 hour on 3 axes)
Functional shock resistance Min. 98 m/s2 (4 times on 3 axes)
Shock resistance Min. 294 m/s2 (5 times on 3 axes)
Output protection level ±7.5 V with clamp element ±3.0 V with clamp element
Permissible clamping frequency -
Ambient temperature range –10 to +50 ℃ +14 to +122 ℉ (without frost and non-condensing)
Storage temperature –20 to +60 ℃ –4 to +140 ℉ (without frost and non-condensing)
Ambient humidity 35 to 80 % RH (at +20 ℃ +68 ℉non-condensing)
Dimensions (mm in)
(W x H x D)
ø42 x 15
1.65 x 0.05
ø70 x19
2.76 x 0.06
ø70 x19
2.76 x 0.06
Weight
(Relay cable included)
70 g approx. 200 g approx. 215 g approx.

Notes :

1) Dedicated CT are dedicated for low voltage under 440 V AC system. They can not be used for high voltage circuit.
2) In each type of Eco-POWER METER excluding AKW8115, KW9M and KW2M, a combination of commercially secondary side 5 A CTs and dedicated CTs for 5 A is used for measuring high voltage circuits; For details, confirm with each respective user's manual.
3) Since dedicated CTs cannot be used when measuring with AKW8115, KW9M and KW2M, please be careful and do not purchase a dedicated CT by mistake.
4) For the AKW8115, KW9M and KW2M, CT with a secondary side current 1 A or 5 A is recommended. Please confirm the specification beforehand.
5) Dedicated CT are not included with Eco-POWER METERs.
6) Each dedicated CT includes a 1 m 3.281 ft relay cable, respectively.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



BY PHONE

FAQ


Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)