Business
> Industrial Devices
> Automation Controls Top
> FA Sensors & Components
> Sensors
> Fiber Sensors
> Digital Fiber Sensor FX-100
> Specifications
|
Type | Standard type | Long sensing range type | |||
---|---|---|---|---|---|
Cable set | Cable set | ||||
Model No. |
NPN output | FX-101(-Z) (Note 5) |
FX-101-CC2 | FX-102(-Z) (Note 5) |
FX-102-CC2 |
PNP output | FX-101P(-Z) (Note 5) |
FX-101P-CC2 | FX-102P(-Z) (Note 5) |
FX-102P-CC2 | |
CE marking directive compliance | EMC Directive, RoHS Directive | ||||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||||
Power consumption | Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) |
||||
Output | <NPN output type> NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less (at 100 mA sink current) <PNP output type> PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less (at 100 mA source current) |
||||
Output operation | Selectable either Light-ON or Dark-ON, at SET mode | ||||
Short-circuit protection |
Incorporated | ||||
External input | <NPN output type> NPN non-contact input • Signal condition High: +8 V to +V DC or Open Low: 0 to +2 V DC (Source current 0.5 mA or less) • Input impedance: 10 kΩ approx. <PNP output type> PNP non-contact input • Signal condition High: +4 V to +V DC (Sink current 0.5 to 3 mA) Low: 0 to +0.6 V DC or Open • Input impedance: 10 kΩ approx. |
||||
Response time | Emission frequency 0: 250 μs or less (factory default setting) Emission frequency 1: 450 μs or less Emission frequency 2: 500 μs or less Emission frequency 3: 600 μs or less |
Emission frequency 1: 2.5 ms or less (factory default setting) Emission frequency 2: 2.8 ms or less Emission frequency 3: 3.2 ms or less Emission frequency 4: 5.0 ms or less |
|||
Sensitivity setting | 2-point teaching / Limit teaching / Full-auto teaching | ||||
Operation indicator | Orange LED (lights up when the output is ON) | ||||
Digital display | 4 digits (green) + 4 digits (red) LCD display | ||||
Fine sensitivity adjustment function |
Incorporated | ||||
Timer function | ON-delay / OFF-delay timer, switchable either effective or ineffective [Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms] |
||||
Emission amount setting function | 3-level + Auto setting (from production in December 2007) | ||||
Interference prevention function |
Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2 or 3) |
Incorporated Emission frequency selection method (Note 2) (Functions at emission frequency 1, 2, 3 or 4) |
|||
Ambient temperature |
–10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are mounted close together: –10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are mounted close together: –10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ |
||||
Ambient humidity |
35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Ambient illuminance |
Incandescent light: 3,000 ℓx or less at the light-receiving face | ||||
Voltage withstandability |
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3) | ||||
Insulation resistance |
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3) | ||||
Vibration resistance |
10 to 150 Hz frequency, 0.75 mm 0.030 in double amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance |
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions five times each | ||||
Emitting element (modulated) |
Red LED (Peak emission wavelength: 643 nm 0.025 mil) | ||||
Material | Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT | ||||
Connecting method | Connector (Note 4) | ||||
Cable length | Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | ||||
Weight | Net weight: 15 g approx. Gross weight: 35 g approx. |
Net weight: 15 g approx. Gross weight: 75 g approx. |
Net weight: 15 g approx. Gross weight: 35 g approx. |
Net weight: 15 g approx. Gross weight: 75 g approx. |
|
Accessory | FC-FX-1 (Protection cover): 1 pc. (Note 6) |
FC-FX-1 (Protection cover): 1 pc. (Note 6) CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1 pc. |
FC-FX-1 (Protection cover): 1 pc. (Note 6) |
FC-FX-1 (Protection cover): 1 pc. (Note 6) CN-14A-C2 (Connector attached cable, 2 m 6.562 ft long): 1 pc. |
Notes:
1): | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2): | When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to different frequency values. However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2. |
3): | The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
4): | Connector attached cable CN-14A-C2 is not attached to the models that have no "-CC2" at the end of the model Nos. Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd. (contact: SPHD-001T-P0.5, housing: PAP-04V-S). |
5): | Model Nos. having the suffix "-Z" are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□. |
6): | Protection cover FC-FX-1 has been attached from production in July, 2011. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])