Type | Standard type | ||||
---|---|---|---|---|---|
Red LED | Blue LED | Green LED | Infrared LED | ||
Model No. |
NPN output | FX-301 | FX-301B | FX-301G | FX-301H |
PNP output | FX-301P | FX-301BP | FX-301GP | FX-301HP | |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||||
Power consumption | <Red LED / Infrared LED type> Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) <Blue LED / Green LED type> Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 430 mW or less (Current consumption 18 mA or less at 24 V supply voltage) |
||||
Output | <NPN output type> NPN open-collector transistor • Maximum sink current:100 mA (50 mA, if five, or more, amplifiers are connected in cascade.) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) sink current.] <PNP output type> PNP open-collector transistor • Maximum source current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade.) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) source current.] |
||||
Output operation | Selectable either Light-ON or Dark-ON, with jog switch | ||||
Short-circuit protection | Incorporated | ||||
Response time | 65 μs or less [H-SP (Red LED type only)], 150 μs or less (FAST), 250 μs or less [STD / S-D (Red LED type only)], 2 ms or less (LONG), selectable with jog switch |
||||
Sensitivity setting | 2-point teaching / Limit teaching / Manual adjustment / Full-auto teaching / Max. sensitivity teaching | ||||
Operation indicator | Orange LED (lights up when the output is ON) | ||||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) | ||||
MODE indicator | RUN: Green LED, TEACH • ADJ • L/D ON • TIMER • PRO: Yellow LED | ||||
Digital display | 4 digit red LED display | ||||
Fine sensitivity adjustment function |
Incorporated | ||||
Timer function | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. [Timer period: Red LED type; 0.5 ms approx., 1 to 9,999 ms (Blue LED, Green LED, Infrared LED type; approx. 0.5 to 500 ms)] |
||||
Light emitting amount selection function |
Incorporated (Red LED type only) (Note 3) FAST, STD, LONG: 4 level, H-SP: 3 level, S-D: 2 level |
||||
Automatic interference prevention function |
Incorporated (Up to four sets of fiber heads can be mounted close together. However, 2 fiber heads in H-SP mode.) (Note 4) | ||||
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are connected in cascade: -10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
||||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||||
Ambient illuminance | Incandescent light: 3,000 ℓx at the light-receiving face | ||||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 6) | ||||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 6) | ||||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | ||||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each | ||||
Emitting element (modulated) | Red LED | Blue LED | Green LED | Infrared LED | |
Peak emission wavelength | 650 nm 0.026 mil | 470 nm 0.019 mil | 525 nm 0.021 mil | 940 nm 0.037 mil | |
Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS (FX-301B/G/H: Acrylic) | ||||
Connecting method | Connector (Note 7) | ||||
Cable length | Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable. | ||||
Weight | Net weight: 20 g approx., Gross weight: 25 g approx. | ||||
Accessory | FX-MB1 (amplifier protection seal): 1 set | - |
Type | High-speed type | High-function type | |
---|---|---|---|
Model No. |
NPN output | FX-301-HS | FX-305 |
PNP output | FX-301P-HS | FX-305P | |
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Power consumption | <Red LED type> Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) |
||
Output | <NPN output type> NPN open-collector transistor • Maximum sink current:100 mA (50 mA, if five, or more, amplifiers are connected in cascade.) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) sink current.] <PNP output type> PNP open-collector transistor • Maximum source current: 100 mA (50 mA, if five, or more, amplifiers are connected in cascade.) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less [at 100 mA (at 50 mA, if five, or more, amplifiers are connected in cascade) source current.] |
<NPN output type> NPN open-collector transistor 2 outputs • Maximum sink current: 50 mA each (Note 2) • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1.5 V or less [at 50 mA (Note 2)] <PNP output type> PNP open-collector transistor 2 outputs • Maximum source current: 50 mA each (Note 2) • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1.5 V or less [at 50 mA (Note 2)] |
|
Output operation | Selectable either Light-ON or Dark-ON, with jog switch | ||
Short-circuit protection | Incorporated | ||
Response time | 35 μs or less (H-SP), 150 μs or less (FAST), 250 μs or less (STD / S-D), 2 ms or less (LONG), selectable with jog switch |
65 μs or less (H-SP), 150 μs or less (FAST), 250 μs or less (STD), 700 μs or less (STDF), 2.5 ms or less (LONG), 4.5 ms or less (U-LG), selectable with jog switch |
|
Sensitivity setting | 2-point teaching / Limit teaching / Manual adjustment / Full-auto teaching / Max. sensitivity teaching | Normal mode: 2-point teaching / Limit teaching / Full-auto teaching / Max. sensitivity teaching / Manual adjustment Window comparator mode: Teaching (1-point / 2-point / 3-point) / Manual adjustment |
|
Operation indicator | Orange LED (lights up when the output is ON) | ||
Stability indicator | Green LED (lights up under stable light received condition or stable dark condition) | - | |
MODE indicator | RUN: Green LED, TEACH • ADJ • L/D ON • TIMER • PRO: Yellow LED | ||
Digital display | 4 digit red LED display | ||
Fine sensitivity adjustment function |
Incorporated | ||
Timer function | Incorporated with variable ON-delay / OFF-delay / ONE SHOT timer, switchable either effective or ineffective. [Timer period: Red LED type; 0.5 ms approx., 1 to 9,999 ms |
Incorporated with variable ON-delay / OFF-delay / ONE SHOT / ON-delay • OFF-delay / ON-delay • ONE SHOT timer, switchable either effective or ineffective. (Timer period: Output 1; 0.5 ms, 1 to 9,999 ms, Output 2; 0.5 ms, 1 to 500 ms) |
|
Light emitting amount selection function |
Incorporated (Note 3) FAST, STD, LONG: 4 level H-SP, S-D: 2 level |
Incorporated (Note 3) FAST, STD, STDF, LONG, U-LG: 4 level H-SP: 3 level |
|
Automatic interference prevention function |
- | Incorporated [Up to four sets of fiber heads can be mounted close together. (However, 8 fiber heads in U-LG mode, 2 fiber heads in H-SP mode.)] (Note 5) |
|
Ambient temperature | -10 to +55 ℃ +14 to +131 ℉ (If 4 to 7 units are connected in cascade: -10 to +50 ℃ +14 to +122 ℉, if 8 to 16 units are connected in cascade: -10 to +45 ℃ +14 to +113 ℉) (No dew condensation or icing allowed), Storage: -20 to +70 ℃ -4 to +158 ℉ |
||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Ambient illuminance | Incandescent light: 3,000 ℓx at the light-receiving face | ||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 6) | ||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 6) | ||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | ||
Shock resistance | 98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each | ||
Emitting element (modulated) |
Red LED | Red LED | |
Peak emission wavelength |
650 nm 0.026 mil | 650 nm 0.026 mil | |
Material | Enclosure: Heat-resistant ABS, Case cover: Polycarbonate, MODE key: Acrylic, Jog switch: Heat-resistant ABS | ||
Connecting method | Connector (Note 7) | ||
Cable length | Total length up to 100 m 328.084 ft (50 m 164.042 ft for 5 to 8 units, 20 m 65.617 ft for 9 to 16 units) is possible with 0.3 mm2, or more, cable. | ||
Weight | Net weight: 20 g approx., Gross weight: 25 g approx. | ||
Accessory | - | FX-MB1 (amplifier protection seal): 1 set |
Notes:
1): | Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉. |
---|---|
2): | 50 mA per output. 25 mA if five, or more, amplifiers are connected in cascade. |
3): | The light emitting amount can be zero (emission halt) in all modes. |
4): | When the power supply is switched on, the light emission timing is automatically set for interference prevention. |
5): | When the interference prevention function "![]() Furthermore, take care that the response time also becomes double. |
6): | The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only. |
7): | The cable for amplifier connection is not supplied as an accessory. Make sure to use the optional quick-connection cables given below. Main cable (3-core) for FX-301(P)(-HS): CN-73-C1 (Cable length 1 m 3.281 ft), CN-73-C2 (Cable length 2 m 6.562 ft), CN-73-C5 (Cable length 5 m 16.404 ft) Sub cable (1-core) for FX-301(P)(-HS): CN-71-C1 (Cable length 1 m 3.281 ft), CN-71-C2 (Cable length 2 m 6.562 ft), CN-71-C5 (Cable length 5 m 16.404 ft) Main cable (4-core) for FX-305(P): CN-74-C1 (Cable length 1 m 3.281 ft), CN-74-C2 (Cable length 2 m 6.562 ft), CN-74-C5 (Cable length 5 m 16.404 ft) Sub cable (2-core) for FX-305(P): CN-72-C1 (Cable length 1 m 3.281 ft), CN-72-C2 (Cable length 2 m 6.562 ft), CN-72-C5 (Cable length 5 m 16.404 ft) |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])