[System Maintenance Notice]
Due to ongoing system maintenance, the site search and specification search functions are temporarily unavailable. We apologize for any inconvenience this may cause and appreciate your understanding.
【Notification of Manufacturer Change for Panasonic Industrial Devices SUNX Products and Panasonic Industrial Devices SUNX Tatsuno Products】
From April 1, 2024, the terms "Panasonic Industrial Devices SUNX Co., Ltd." and "Panasonic Industrial Devices SUNX Tatsuno Co., Ltd."
in this page and in the manuals and other documents to be downloaded will all be replaced with "Panasonic Industry Co., Ltd." and applied accordingly.
Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Fiber Sensors > Color Detection Fiber Sensor FZ-10 > Specifications
Type | NPN output | PNP output | |
---|---|---|---|
Model No. | FZ-11 | FZ-11P | |
Applicable fibers | FD-L51, FD-L52, FD-L53, FD-L54 | ||
Supply voltage | 12 to 24 V DC ±10 % Ripple P-P 10 % or less | ||
Current consumption | 45 mA or less | ||
Sensing object | Opaque or translucent object larger than the spot diameter of the applicable fiber (Note 2) | ||
Output | NPN open-collector transistor • Maximum sink current: 100 mA • Applied voltage: 30 V DC or less (between output and 0 V) • Residual voltage: 1 V or less (at 100 mA sink current) 0.4 V or less (at 16 mA sink current) |
PNP open-collector transistor • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between output and +V) • Residual voltage: 1 V or less (at 100 mA source current) 0.4 V or less (at 16 mA source current) |
|
Utilization category | DC-12 or DC-13 | ||
Output operation | Switchable either Coincident-ON or Incoincident-ON | ||
Short-circuit protection | Incorporated | ||
Response time | 1 ms or less (3 ms or less when auto-teaching has been engaged) | ||
Indicators | Power indicator: Green LED (lights up when the power is ON, blinks during auto-teaching) Operation indicator: Red LED (lights up when the output is ON) * Both blink alternately when a manual teaching error occurs Both blink simultaneously when the output is short-circuited |
||
Timer function | Approx. 40 ms fixed OFF-delay timer (switchable either effective or ineffective) | ||
Teaching | Button operation, Switchable either manual-teaching or auto-teaching | ||
Tolerance | Adjustable in 16 grades with the tolerance adjuster | ||
Pollution degree | 3 (Industrial environment) | ||
Ambient temperature | –10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note 3), Storage: –20 to +70 ℃ –4 to +158 ℉ |
||
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH | ||
Ambient illuminance | Incandescent light: 3,000 lx at the light-receiving face | ||
EMC | EN 60947-5-2 | ||
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 4) | ||
Insulation resistance | 20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 4) | ||
Vibration resistance | 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each | ||
Shock resistance | 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions for three times each | ||
Emitting element | Red LED / Green LED / Blue LED (Peak emission wavelength: 644 nm 0.025 mil / 525 nm 0.021 mil / 470 nm 0.019 mil, modulated) | ||
Material | Enclosure: ABS, Case cover: Polycarbonate, Fiber lock lever: PPS | ||
Cable | 0.2 mm2 3-core cabtyre cable, 2 m 6.562 ft long | ||
Cable extension | Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable. | ||
Weight | Net weight: 85 g approx. | ||
Accessories | MS-DIN-3 (Amplifier mounting bracket): 1 pc., Adjusting screwdriver: 1 pc. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) Make sure to confirm detection with an actual sensor before use.
3) The amplifier should be used under the ambient temperature of +15 to +35 ℃ +59 to +95 ℉ when the tolerance adjuster is set from the 1st grade to the
4th grade, which provide fine color resolution.
4) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
Type | Standard | High precision | Extremely small spot | Long sensing range |
---|---|---|---|---|
Model No. | FD-L51 | FD-L52 | FD-L53 | FD-L54 |
Applicable amplifiers |
FZ-11, FZ-11P | |||
Sensing range (Note 2) |
14 to 24 mm 0.511 to 0.945 in |
8 to 11 mm 0.315 to 0.433 in |
4 to 6 mm 0.157 to 0.236 in |
30 to 50 mm 0.181 to 1.969 in |
Setting distance | 20 mm 0.787 in(fixed) |
10 mm 0.394 in(fixed) |
5 mm 0.197 in(fixed) |
40 mm 1.575 in(fixed) |
Spot diameter (at setting distance) |
φ5 mm φ0.197 in |
φ2.5 mm φ0.098 in |
φ1 mm φ0.039 in |
φ8 mm φ0.315 in |
Allowable bending radius |
R25 mm R0.984 in or more (Note 3) | |||
Fiber cable length | 1 m 3.281 ft | |||
Ambient temperature |
–20 to +70 ℃ –4 to +158 ℉ (No dew condensation or icing allowed), Storage: –20 to +70 ℃ –4 to +158 ℉ |
|||
Ambient humidity |
35 to 85 % RH, Storage: 35 to 85 % RH | |||
Material | Fiber core: Acrylic, Sheath: Polyethylene, Fiber head: Polycarbonate, Lens: Polyalylate (FD-L54: Acrylic) | |||
Weight | Net weight: 15 g approx. |
Notes:
1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 ℃ +73.4 ℉.
2) The sensing range of each fiber is the range for which white non-glossy paper can be detected at the sensitivity for which teaching has been done with a white non-glossy paper (50 x 50 mm 1.969 x 1.969 in ) at the respective rated setting distance and at the 16th grade (▲ mark) of tolerance.
3) If the fiber cable is bent at less than R25 mm R0.984 in or less, the detectability may deteriorate.
4) Since fiber FD-L51 (standard type) is easily affected by specular reflection, it is possible that teaching may not be properly done or sensing may be
unstable if objects of high reflectivity (mirror, plated objects, copper foil, etc.) are sensed. When such objects are to be sensed, please use FD-L52 (high precision type) or FD-L53 (extremely small spot type) and make sure that the projected optical beam is perpendicular to the object surface.
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)