CMOS type Micro Laser Distance Sensor HG-C

Specifications

Type Measurement center
200mm type
Measurement center
400mm type
Model No. NPN output HG-C1200 HG-C1400
PNP output HG-C1200-P HG-C1400-P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification (Note 4)
Measurement center distance 200 mm 7.874 in 400 mm 15.748 in
Measurement range ±80 mm 3.150 in ±200 mm 7.874 in
Repeatability 200 μm 7.874 mil 300 μm 11.811 mil
(Measuring distance 200 to 400 mm 7.874 to 15.748 in)
800 μm 31.496 mil
(Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Linearity ±0.2 % F.S. ±0.2 % F.S.
(Measuring distance 200 to 400 mm 7.874 to 15.748 in)
±0.3 % F.S.
(Measuring distance 400 to 600 mm 15.748 to 23.622 in)
Temperature characteristic 0.03 % F.S./℃
Light source Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note 2)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil
Beam diameter (Note 3) ø300 μm 11.811 mil
approx.
ø500 μm 19.685 mil
approx.
Supply voltage 12 to 24 V DC ±10 %, Ripple P-P 10 % or less
Power consumption 40 mA or less (at 24 V DC supply voltage), 65 mA or less (at 12 V DC supply voltage)
Control output <NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to 0V)
• Residual voltage: 1.5 V or less (At 50 mA sink current)
• Leakage current: 0.1 mA or less

<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to +V)
• Residual voltage: 1.5 V or less (At 50 mA source current)
• Leakage current: 0.1 mA or less
  Output operation Switchable between either Light-ON or Dark-ON
Short-circuit protection Incorporated (Auto reset type)
Analog output Analog voltage output
• Output range: 0 to 5 V (at alarm: +5.2 V)
• Output impedance: 100Ω

Analog current output
• Output range: 4 to 20mA (at alarm: 0 mA)
• Output impedance: 300Ω or less
Response time Switchable between 1.5 ms / 5 ms / 10 ms
External input <NPN output type>
NPN non-contact input
• Input conditions
Invalid: +8 to +V DC or Open
Valid: 0 to +1.2 V DC
• Input impedance: 10 kΩ approx.

<PNP output type>
PNP non-contact input
• Input conditions
Invalid: 0 to +0.6 V DC or Open
Valid: +4 to +V DC
• Input impedance: 10 kΩ approx.
Pollution degree 2
Operating altitude 2,000 m 6561.680 ft or less
Environmental
resistance
Protection IP67 (IEC)
Ambient temperature -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to 140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light: 3,000 ℓx or less at the light-receiving face
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Cable 0.2 mm2 5-core composite cable, 2 m 6.5617 ft long
Cable extension Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Material Enclosure: Aluminum die-cast, Front cover: Acrylic
Weight Net weight: 35 g approx. (without cable), 85 g approx. (including cable)

Note1 : Supply voltage: 24V DC, ambient temperature: +20℃ +68℉, response time: 10ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
Note2 : This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
Note3 : This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
Note4 : The UL/c-UL certified products have been shipped since April, 2017.

Type Measurement center
30mm type
Measurement center
50mm type
Measurement center
100mm type
Model No. NPN output HG-C1030 HG-C1050 HG-C1100
PNP output HG-C1030-P HG-C1050-P HG-C1100-P
Applicable regulations and certifications CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), FDA Regulations, UL/c-UL Certification (Note 4)
Measurement center distance 30 mm 1.181 in 50 mm 1.969 in 100 mm 3.937 in
Measurement range ±5 mm 0.197 in ±15 mm 0.591 in ±35 mm 1.328 in
Repeatability 10 μm 0.394 mil 30 μm 1.181 mil 70 μm 2.756 mil
Linearity ±0.1 % F.S.
Temperature characteristic 0.03 % F.S./℃
Light source Red semiconductor laser Class 2 [JIS/IEC/GB/FDA (Note 2)] Max. output: 1 mW, emission peak wavelength: 655 nm 0.026 mil
Beam diameter (Note 3) ø50 μm 1.969 mil
approx.
ø70 μm 2.756 mil
approx.
ø120 μm 4.724 mil
approx.
Supply voltage 12 to 24 V DC ±10 %, Ripple P-P 10 % or less
Power consumption 40 mA or less (at 24 V DC supply voltage), 65 mA or less (at 12 V DC supply voltage)
Control output <NPN output type>
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to 0V)
• Residual voltage: 1.5 V or less (At 50 mA sink current)
• Leakage current: 0.1 mA or less

<PNP output type>
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less (Between control output to +V)
• Residual voltage: 1.5 V or less (At 50 mA source current)
• Leakage current: 0.1 mA or less
  Output operation Switchable between either Light-ON or Dark-ON
Short-circuit protection Incorporated (Auto reset type)
Analog output Analog voltage output
• Output range: 0 to 5 V (at alarm: +5.2 V)
• Output impedance: 100Ω

Analog current output
• Output range: 4 to 20mA (at alarm: 0mA)
• Output impedance: 300Ω or less
Response time Switchable between 1.5 ms / 5 ms / 10 ms
External input <NPN output type>
NPN non-contact input
• Input conditions
Invalid: +8 to +V DC or Open
Valid: 0 to +1.2 V DC
• Input impedance: 10 kΩ approx.

<PNP output type>
PNP non-contact input
• Input conditions
Invalid: 0 to +0.6 V DC or Open
Valid: +4 to +V DC
• Input impedance: 10 kΩ approx.
Pollution degree 2
Operating altitude 2,000 m 6561.680 ft or less
Environmental
resistance
Protection IP67 (IEC)
Ambient temperature -10 to +45 ℃ -14 to 113 ℉ (No dew condensation or icing allowed),
Storage: -20 to +60 ℃ -4 to 140 ℉
Ambient humidity 35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance Incandescent light : 3,000 ℓx or less at the light-receiving face
Vibration resistance 10 to 55 Hz (period: 1 min.) frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
Shock resistance 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each
Cable 0.2 mm2 5-core composite cable, 2 m 6.5617 ft long
Cable extension Extension up to total 10 m 393.701 ft is possible with 0.3 mm2, or more, cable.
Material Enclosure: Aluminum die-cast, Front cover: Acrylic
Weight Net weight: 35 g approx. (without cable), 85 g approx. (including cable)

Note1 : Supply voltage: 24V DC, ambient temperature: +20℃ +68℉, response time: 10ms, and analog output value of measurement center distance are used for unspecified measurement conditions. The subject is white ceramics.
Note2 : This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH (Center for Devices and Radiological Health) under the FDA (Food and Drug Administration).
Note3 : This is the size in the measurement center distance. These values were defined by using 1/e2 (13.5% approx.) of the center light intensity. Due to leak light outside the specified area, the reflectance around the detecting point may be higher than at the point and this may affect the measurement value.
Note4 : The UL/c-UL certified products have been shipped since April, 2017.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)