Please note that it doesn't work when connecting the communication module SF4D-TM1 manufactured before November 2019 to Type 4 Compact & Robust Safety Light Curtain SF4D series Ver.3.0 manufactured after March 17, 2020.
Compatibility of SF4D Ver. and SF4D-TM1
SF4D Ver. 2.0 (manufactured before March 16, 2020) |
SF4D Ver. 3.0 (manufactured after March 17, 2020) |
|
---|---|---|
SF4D-TM1 (manufactured before November 2019) |
Yes | No |
SF4D-TM1 Ver. 2.0 (manufactured after December 2019) |
Yes | Yes |
■Compact & Robust Safety Light Curtain SF4D Series
Production lot | manufactured before March 16, 2020 | manufactured after March 17, 2020 |
---|---|---|
Version of main body | Ver. 2.0 | Ver. 3.0 |
Front nameplate | Receiver![]() |
Receiver![]() |
Side nameplate | Receiver![]() |
Receiver![]() |
■Communication module SF4D-TM1
Production lot | manufactured before November 2019 | manufactured after December 2019 |
---|---|---|
Version of main body | - | Ver. 2.0 |
Communication module SF4D-TM1 |
![]() |
![]() |
Setting software Configurator Light Curtain |
Version info. Ver.1.3.0 |
Version info. Ver.1.4.0 |
|
Designation | Function | ||||
---|---|---|---|---|---|
Line synchronization | Optical synchronization | ||||
Receiver | Emitter | Receiver | Emitter | ||
Upper application indicator (Blue / Green / Red / Orange) |
When beam axis adjustment mode is set |
All beams received [Control output (OSSD 1, OSSD 2) ON]: Lights blue Top beam received: Lights red, Top beam blocked: Turns OFF |
Turns OFF | ||
When application mode is set |
When application indicator input 1 is ON: Lights green When application indicator input 2 is ON: Lights red When application indicator input 1 / 2 are ON: Lights orange When application indicator input 1 / 2 are OFF: Turns OFF |
Turns OFF | |||
Lower application indicator (Blue / Green / Red / Orange) |
When beam axis adjustment mode is set |
All beams received [Control output (OSSD 1, OSSD 2) ON]: Lights blue Bottom beam received: Lights red, Bottom beam blocked: Turns OFF |
Turns OFF | ||
When application mode is set |
When application indicator input 1 is ON: Lights green When application indicator input 2 is ON: Lights red When application indicator input 1 / 2 are ON: Lights orange When application indicator input 1 / 2 are OFF: Turns OFF |
Turns OFF | |||
Stable light incidence indicator (Green / Orange) |
When light reception is stable: Lights green When light reception is unstable: Lights orange When light is blocked: Turns OFF |
Turns OFF | |||
Digital indicator (Green / Yellow) |
Light receiving intensity (Green) |
Incident light level 3: Lights green "![]() Incident light level 2: Lights green " ![]() Incident light level 1: Lights green " ![]() When light is blocked: Turns OFF |
Turns OFF | ||
Error (Yellow) | Normal operation: Turns OFF, Error: Yellow number blinks or lights "![]() |
||||
Polarity (Yellow) | When PNP output is set: Lights yellow "![]() When NPN output is set: Lights yellow " ![]() |
||||
Frequency indicator (Orange) | - | When frequency 1 is set: Lights orange "![]() When frequency 2 is set: Lights orange " ![]() |
Designation (Note 1) |
Function | |
---|---|---|
Line synchronization | Optical synchronization | |
Light emission intensity control indicator (Orange) [CTRL] | Short mode: Turns OFF, Long mode: Lights orange | |
Test indicator (Orange) [TEST] | During test: Lights orang, Normal operation: Turns OFF | |
Operation indicator (Green / Red) [OP] | Control output (OSSD 1 / 2) ON: Lights green Control output (OSSD 1 / 2) OFF: Lights red |
Normal operation: Lights green Error: Lights red |
Designation (Note 1) |
Function | |
---|---|---|
Line synchronization | Optical synchronization | |
Function setting indicator (Orange) [FUNC] | When communication module is connected: Blinks orange, When blanking function or parallel connection is used: Lights orange (Note 2) | |
Interlock indicator (Yellow) [LOCK] | Interlock activated: Lights yellow, All other times: Turns OFF | |
OSSD indicator (Green / Red) [OSSD] | Control output (OSSD 1 / 2) ON: Lights green Control output (OSSD 1 / 2) OFF: Lights red |
Notes:
1) | Designations in brackets [ ] are names that are indicated on the device. |
---|---|
2) | For the details of blanking function and parallel connection, refer to the instruction manual. |
・ | This web site is a guide to select a suitable product. Be sure to read instruction manual attached to the product prior to its use. |
---|
Item | Specifications |
---|---|
Machine type | Press equipped with immediate stopping mechanism and restart prevention mechanism |
Pressing capacity | 50,000 kN or less |
Immediate stopping time | 500 ms or less |
Stroke length | Within (Protective height – Die height) |
Die size | Within bolster width |
Item | Specifications |
---|---|
Machine type | Shearing machine (paper cutting machine) equipped with immediate stopping mechanism and restart prevention mechanism |
Cutting thickness | 200 mm 7.874 in or less |
Cutting width | 5,000 mm 196.850 in or less |
Cutter length | 5,500 mm 216.535 in or less |
・ | For the details of function settings made using the SF4D-TM1 communication module (optional), see the manual for the communication module. |
---|
|
|
|
Min. sensing object when applying floating blanking function | ||||||
---|---|---|---|---|---|---|
Not set | Setting (Note) | |||||
1beam channel |
2beam channels |
3beam channels |
4beam channels |
5beam channels |
||
SF4D-F□ | ø14 mm ø0.551 in |
ø24 mm ø0.945 in |
ø34 mm ø1.339 in |
ø44 mm ø1.732 in |
ø54 mm ø2.126 in |
ø64 mm ø2.520 in |
SF4D-H□ | ø25 mm ø0.984 in |
ø45 mm ø1.772 in |
ø65 mm ø2.559 in |
ø85 mm ø3.346 in |
ø105 mm ø4.134 in |
ø125 mm ø4.921 in |
SF4D-A□ | ø45 mm ø1.772 in |
ø85 mm ø3.346 in |
ø125 mm ø4.921 in |
ø165 mm ø6.496 in |
ø205 mm ø8.071 in |
ø245 mm ø9.646 in |
Note: | When SF4D-□-01 is used, the floating blanking function cannot be used. |
---|
For use based on EN ISO 13855 / ISO 13855 / JIS B 9715 |
• Equation (1) S = K × T + C
S: | Safety distance (mm) Minimum required distance between the sensing area plane and the dangerous part of the machine |
---|---|
K: | Intrusion speed of person or object (mm/sec.) Normally 2,000 (mm/sec.) is used. |
T: | Response time of overall system T = Tm + TSF4D Tm: Maximum response time of machine (sec.) TSF4D: Response time of device (sec.) |
C: | Additional distance calculated from the minimum sensing object of the device (mm) The value of C cannot be less than 0. C = 8 × (d − 14) d: Diameter of minimum sensing object (mm) |
・ | When calculating the safety distance S, the following five cases must be considered. First calculate using K = 2,000 (mm/sec.) in the above equation. Consider these three cases for the result: 1) S < 100, 2) 100 ≤ S ≤ 500, and 3) S > 500. If the result of the calculation is 3) S > 500, calculate again using K = 1,600 (mm/sec.). Consider these two cases for the result: 4) S ≤500 and 5) S > 500. For details, refer to the manual. |
---|---|
・ | When the device is used in "PSDI mode", an appropriate safety distance S must be calculated. For details, refer to the standards and regulations that apply in your region or country. |
• Equation S = K × T + C
S: | Safety distance (mm) Minimum required distance between the sensing area plane and the nearest dangerous part of the machine |
---|---|
K: | Intrusion speed of person or object (mm/sec.) Normally 1,600 (mm/sec.) is used. |
T: | Overall response time of system T = Tm + TSF4D Tm: Maximum response time of machine (sec.) TSF4D: Response time of device (sec.) |
C: | Additional distance calculated from the minimum sensing object of the device (mm) C = 850 (mm) (Constant) |