Business
> Industrial Devices
> Automation Controls Top
> FA Sensors & Components
> Sensors
> Light Curtains / Safety Components
> Ultra-slim Safety door switch SG-A1
> Specifications
|
Designation | Safety door switch | ||||||
---|---|---|---|---|---|---|---|
Series | SG-A1 series | ||||||
Applicable standards |
EN 1088, IEC 60947-5-1, EN 60947-5-1, GS-ET-15, UL 508, CSA C22.2 No.14 |
||||||
Standards for use | IEC 60204-1, EN 60204-1 | ||||||
Applicable regulations | CE Marking [Machinery Directive(2006/42/EC), RoHS Directive], UKCA Marking [Machinery Regulations(2008 No.1597), RoHS Regulations] | ||||||
Operating condition |
Ambient temperature |
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage: -40 to +80 ℃ -40 to +176 ℉ |
|||||
Ambient humidity | 45 to 85 % RH | ||||||
Pollution degree | 3 (Inside 2) | ||||||
Altitude | 2,000 m 6,561.68 ft max. | ||||||
Impulse withstand voltage (Uimp) |
4 kV | ||||||
Rated insulation voltage (Ui) |
300 V | ||||||
Thermal current (Ith) |
2.5 A | ||||||
Rated operational voltage (Ue) / Rated operational current (Ie) |
Ue | ||||||
30V | 125V | 250V | |||||
Ie | AC | Resistive load (AC-12) | - | 2.5A | 1.5A | ||
Inductive load (AC-15) | - | 1.5A | 0.75A | ||||
DC | Resistive load (DC-12) | 2.5A | 1.1A | 0.55A | |||
Inductive load (DC-13) | 2.3A | 0.55A | 0.27A | ||||
Electric shock protection class |
Class II (IEC 61140), 回(double insulated) | ||||||
Protection | IP 67 (IEC 60529) | ||||||
Shock resistance | Malfunction: 300 m/s2 Destruction: 1,000 m/s2 |
||||||
Vibration resistance |
Malfunction: 5 to 55 Hz, half amplitude 0.5 mm 0.020 in Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in |
||||||
Operating frequency |
1,200 operations/hour | ||||||
Actuator operating speed |
0.05 to 1.0 m/sec. | ||||||
B10d | 2,000,000 (ISO 13849-1 Annex C Table C.1) |
||||||
Mechanical durability |
1,000,000 operations min. (GS-ET-15) | ||||||
Electrical durability |
100,000 operations min. (AC-12, 250 V 1.5 A, DC-12 250 V 0.2 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (1,200 operations/hour) |
||||||
Direct opening travel | 8 mm 0.315 in min. | ||||||
Direct opening force | 60 N min. | ||||||
Contact resistance |
300 mΩ max. (initial value, 1 m 3.281 ft cable) 700 mΩ max. (initial value, 5 m 16.404 ft cable) |
||||||
Short-circuit protective device |
Use 250 V / 10 A fast acting type fuse | ||||||
Conditional short-circuit current |
50 A (250 V) | ||||||
Material | Enclosure: PA66 | ||||||
Cable | UL style 2464, No.20 AWG 6-core | ||||||
Weight | SG-A1-□-1: Approx. 120 g, SG-A1-□-5: Approx. 420 g |
|
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)