Business > Industrial Devices > Automation Controls Top > FA Sensors & Components > Sensors > Light Curtains / Safety Components > Safety door switch with key SG-B2 > Specifications
Designation | Safety door switch with key | ||||||
---|---|---|---|---|---|---|---|
Series | SG-B2 series | ||||||
Applicable standards |
EN 60947-5-1, GS-ET-19 | ||||||
Standards for use | IEC 60204-1 / EN 60204-1, ISO 14119, EN ISO 14119, IEC 60947-5-1, UL 508, CSA C22.2 No.14 | ||||||
Applicable regulations | CE Marking [Machinery Directive (2006/42/EC), RoHS Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoHS Regulations] | ||||||
Operating condition |
Ambient temperature |
-25 to +70 ℃ -13 to +158 ℉ (No dew condensation or icing allowed) Storage: -40 to +80 ℃ -40 to +176 ℉ |
|||||
Ambient humidity | 45 to 85 % RH | ||||||
Pollution degree | 3 (Inside 2) | ||||||
Altitude | 2,000 m 6,561.68 ft max. | ||||||
Impulse withstand voltage (Uimp) |
2.5 kV | ||||||
Rated insulation voltage (Ui) |
250 V (Note 1) | ||||||
Thermal current (Ith) |
2.5 A | ||||||
Ambient temperature: -25 to +60 ℃ -13 to +140 ℉: 2.5 A max. +60 to +65 ℃ +140 to +149 ℉: 1.5 A max. +65 to +70 ℃ +149 to +158 ℉: 1.0 A max. |
|||||||
Rated operational voltage (Ue) / Rated operational current (Ie) |
Ue | ||||||
30V | 125V | 250V | |||||
Ie | AC | Resistive load (AC-12) | - | 2.5A | 1.5A | ||
Inductive load (AC-15) | - | 1.5A | 0.75A | ||||
DC | Resistive load (DC-12) | 2.5A | 1.1A | 0.55A | |||
Inductive load (DC-13) | 2.3A | 0.55A | 0.27A | ||||
Operating frequency | 900 operations/hour | ||||||
Actuator operating speed | 0.05 to 1.0 m/sec. | ||||||
B10d | 2,000,000 (ISO 13849-1 Annex C Table C.1) |
||||||
Mechanical durability |
1,000,000 operations min. (GS-ET-19) Rear unlocking button: 3,000 operations min. (Type SG-B2-□-L5) |
||||||
Electrical durability |
100,000 operations min. (AC-12, 250 V 1 A) 1,000,000 operations min. (AC/DC 24 V 100 mA) (900 operations/hour) |
||||||
Electric shock protection class |
Class II (IEC 61140) (Note 2), 回(double-insulated) | ||||||
Interlock force | 1,400 N min. (GS-ET-19) (Note 3) (500 N min. : SG-K24 actuator) |
||||||
Direct opening travel |
11 mm 0.433 in min. (actuator: SG-K21) 12 mm 0.472 in min. (for other actuators) |
||||||
Direct opening force | 80 N min. | ||||||
Contact resistance | 700 mΩ max. (initial value, 5 m 16.404 ft cable) | ||||||
Protection | IP 65 (IEC 60529) | ||||||
Shock resistance | Malfunction: 100 m/s2, Destruction: 1,000 m/s2 | ||||||
Vibration resistance |
Malfunction: 10 to 55 Hz, half amplitude 0.35 mm 0.014 in Destruction: 30 Hz, half amplitude 1.5 mm 0.059 in |
||||||
Conditional short-circuit current |
50 A (250 V) | ||||||
Short-circuit protective device |
Use 250 V / 10 A fast acting type fuse | ||||||
Material | Enclosure: PA66 | ||||||
Cable | UL style 2464, No.22 AWG 12-core | ||||||
Key | Operating specifications |
2 positions | |||||
Mechanical durability |
100,000 operations min. | ||||||
Key operating durability |
10,000 operations min. | ||||||
Key tensile strength |
1.0 N・m min. | ||||||
Direct opening force |
0.6 N・m min. | ||||||
Direct opening degree |
60°min. | ||||||
Weight | SG-B2-□-5: Approx. 680 g, SG-B2-□-L5: Approx. 700 g |
Notes:
1) | Ratings approved by UL, c-UL: 125 V |
---|---|
2) | Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits. When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
3) | The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)