INPUT | OUTPUT | ||
---|---|---|---|
Terminal No. | Signal | Terminal No. | Signal |
1 | START1 | 13 | READY-All |
2 | START2 | 14 | READY/BUSY1 (Note 2) |
3 | START3 | 15 | READY/BUSY2 (Note 2) |
4 | START4 | 16 | READY/BUSY3 (Note 2) |
5 | TYPE Chg1 (Note 1) | 17 | READY/BUSY4 (Note 2) |
6 | TYPE Chg2 (Note 1) | 18 | ERROR |
7 | TYPE Chg3 (Note 1) | 19 | ALARM |
8 | UV CHECK (Note 1) | 20 | COM |
9 | STOP | 21 | COM |
10 | START-All | 22 | FG |
11 | INTERLOCK (Note 3) | 23 | +5 V DC |
12 | COM | 24 | COM |
Notes:
1) | Nos. 5 / 6 / 7 / 8 (Type-Chg 1 / 2 / 3 and UV-CHECK) are functions available UJ35 only. These terminals for UJ30 are spare. |
---|---|
2) | The READY/BUSY switching of Nos. 14 / 15 / 16 / 17 is performed on the UJ30 / UJ35 controller. |
3) | At shipment, for B-contact (allows irradiation when ON), No.11 (INTERLOCK) is connected to No.12 (COM) by a short-circuit line. |