AUTOMATION
CONTROLS

Search
Discontinued
Products



Aicure UJ30/35 LED Spot Type UV Curing Systems (Discontinued Products)

I/O Circuit and Wiring diagrams

Input and Output specifications

Input specifications

Input specifications

Contact input

Contact input

Non-contact input

Non-contact input

Output specifications

Output specifications

With external power supply

With external power supply

With internal power supply

With internal power supply

I/O list

INPUT OUTPUT
Terminal No. Signal Terminal No. Signal
1 START1 13 READY-All
2 START2 14 READY/BUSY1 (Note 2)
3 START3 15 READY/BUSY2 (Note 2)
4 START4 16 READY/BUSY3 (Note 2)
5 TYPE Chg1 (Note 1) 17 READY/BUSY4 (Note 2)
6 TYPE Chg2 (Note 1) 18 ERROR
7 TYPE Chg3 (Note 1) 19 ALARM
8 UV CHECK (Note 1) 20 COM
9 STOP 21 COM
10 START-All 22 FG
11 INTERLOCK (Note 3) 23 +5 V DC
12 COM 24 COM

Notes:

1) Nos. 5 / 6 / 7 / 8 (Type-Chg 1 / 2 / 3 and UV-CHECK) are functions available UJ35 only.
These terminals for UJ30 are spare.
2) The READY/BUSY switching of Nos. 14 / 15 / 16 / 17 is performed on the UJ30 / UJ35 controller.
3) At shipment, for B-contact (allows irradiation when ON), No.11 (INTERLOCK) is connected to No.12 (COM) by a short-circuit line.

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region




Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)