AEWA1100 | Air Flow Monitor EWA1(Discontinued)


Air Flow Monitor EWA1(Discontinued)

*Photo may vary from actual product.


  • Discontinued
  • Last time buyAugust 31, 2015
Product Number AEWA1100
Part Number AEWA1100
Details Large pipe size
Product name Air Flow Monitor EWA1(Discontinued)

Spec Detail As of August 31, 2015

Item Specifications
Product Number AEWA1100
Part Number AEWA1100

COMMON SPECIFICATIONS

Item Specifications
Rated pressure range 0 to 1 MPa (gauge pressure)
Measurable fluid Air (compressed air)
Rated operating voltage 24 V DC plus or minus 10 %
Rated power consumption 40 mA or less
Pulse output(Pulse output 1 and Pulse output 2) Open drain output
-Max. inflow current: 10 mA
-Applied voltage: 24 V DC or less
-Residual voltage: 1 V or less (at inflow current 10 mA)
Pulse output(Pulse output 1 and Pulse output 2):Output mode Pulse output 1: Direct flow pulse
Pulse output 2: Reverse flow pulse, Flow limit alarm (select by button operation)
Pulse output(Pulse output 1 and Pulse output 2):Over current protection Equipped
Pulse output(Pulse output 1 and Pulse output 2):Pulse output duty 1: 1 (35 to 65 %)
Analog current output Output current: 4 to 20 mA
Output accuracy: plus or minus 0.1 mA
Max. external load: 400 Ohm or less
Analog current output:Output mode Instant flow, air pressure and temperature (select by button operation)
Analog current output:Output mode:Instant flow Zero point: 4 mA (Direct flow display mode, reverse flow ~ within low flow cut off), 12 mA (Direct/Reverse flow display mode, within low flow cut off)
Analog current output:Output mode:Air pressure 0 kPa: 4 mA
1 MPa: 20 mA
Analog current output:Output mode:Temperature −10 degrees +14 degrees Fahrenheit: 4 mA
+60 degrees +140 degrees Fahrenheit: 20 mA
Pressure loss Extremely small (same as straight pipe)
Response time 500 ms
Enclosure protection IP64 (IEC)
Ambient temperature −10 to +60 degrees +14 to +140 degrees Fahrenheit (Storage: −20 to +70 degrees −4 to +158 degrees Fahrenheit )
Ambient humidity 90 % RH or less (No dew condensation or icing allowed)

INDIVIDUAL SPECIFICATIONS

Item Specifications
Pipe size 100 A (4B)
Flow range (actual flow) −10 to −500 m3 / h or +10 to +500 m3 / h
Flow measuring accuracy:±5 % R.S. −10 to −50 m3 / h or +10 to +50 m3 / h
Flow measuring accuracy:±2 % R.S. −50 to −500 m3 / h or +50 to +500 m3 / h
Normal conversion accuracy plus or minus 2 % R.S. (at dry air, ordinary temperatures and 0.5 MPa)
Unit for pulse output 0.1, 1, 10 Nm3 / pulse or m3 / pulse
Low flow cut off Within plus or minus 2.6 m3 / h
Material Measuring pipe: Stainless steel alloy, PPS and phlor silicone rubber
Net weight 10.3 kg approx.
Accessories Positioning collar: 2 pcs
M4 hexagon wrench: 1 pc

Return to top

Accessories (Option) As of August 31, 2015

no_image
Product Number AEWA1C05
Part Number AEWA1C05
Product name EWA1/EWA2 Connecting cable
no_image
Product Number AEWA1C20
Part Number AEWA1C20
Product name EWA1/EWA2 Connecting cable

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE SEARCH FAQ

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



BY PHONE

FAQ

Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)