Product Number | EX-F61-PN-C5 |
Part Number | EX-F61-PN-C5 |
Product | Leak Detection Sensor |
Details | Chemical-resistant |
Product name | Leak Detection Sensor EX-F70/EX-F60 |
As of May 19, 2024
Specifications and design of the products are subject to change without notice for the product improvement.
Item | Specifications |
---|---|
Product Number | EX-F61-PN-C5 |
Part Number | EX-F61-PN-C5 |
Sensing object | Agent, such as Water, Sulfuric acid, Hydrochloric acid, Phosphoric acid or Ammonia etc. Note : Highly viscous liquid may not be detected stably. Note : The agents mentioned above are examples. For details, please contact our office. Note : PVC mounting bracket may not be used depending on type or viscosity etc. of the agent. For details, please contact our office. |
Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P 10 % or less |
Current consumption | 15 mA or less |
Output | PNP open-collector transistor - Maximum source current: 50 mA - Applied voltage: 30 V DC or less (between output and +V) - Residual voltage: 1.0 V or less (at 50 mA source current), 0.4 V or less (at 16 mA source current) |
Output:Output operation | In normal state: ON, When leak detected or the sensor is mounted improperly: OFF |
Output:Short-circuit protection | Incorporated |
Response time | 50 ms or less |
FAULT indicator | Red LED (lights up when the leak liquid is detected, or the sensor is mounted improperly) |
NORMAL indicator | Green LED (lights up when the sensor is mounted properly) |
Protection | IP67 (IEC) |
Ambient temperature | -10 to +60 ℃ +14 to +140 ℉ (No dew condensation or icing allowed), Storage: -20 to +70 ℃ - 4 to +158 ℉ Note : Liquid being detected should also be kept within the rated ambient temperature range. |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 1,000 ℓx or less at the light-receiving face |
Emitting element | Infrared LED (non-modulated) |
Material | Enclosure: PFA |
Cable extension | Extension up to total 50 m |
Accessory | MS-EX-F6-1(PFA mounting bracket): 1 pc. |