[Notification of CAD Data Download Issue]
We regret to inform you that we are currently experiencing issues with downloading CAD data for some products.
We are investigating the cause of this problem. We apologize for any inconvenience this may cause and appreciate your understanding.
Business > Industrial Devices > Automation Controls Top > RX2-M5-C5
*Photo may vary from actual product.
Product Number | RX2-M5-C5 |
Part Number | RX2-M5-C5 |
Product | Robust Photoelectric Sensor |
Details | DC 2-wire type Thru-beam |
Product name | Robust Photoelectric Sensor RX(Discontinued) |
Item | Specifications |
---|---|
Product Number | RX2-M5-C5 |
Part Number | RX2-M5-C5 |
Regulatory compliance | EMC Directive, RoHS Directive |
Sensing range | 5 m 16.404 ft |
Sensing object | dia. 10 mm dia. 0.394 in or more opaque object (Note) If slit masks (optional) are fitted, an object of 0.5 x 5 mm 0.020 x 0.197 in can be detected. |
Hysteresis | - |
Repeatability(perpendicular to sensing axis) | 0.5 mm 0.020 in or less |
Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
Current consumption | Emitter: 8 mA or less Receiver: 0.8 mA or less (Note) It is the leakage current when the output is in the OFF state. |
Sensing output | Non contact DC 2-wire type - Load current: 5 to 100 mA - Residual voltage: 4 V or less (Note) (Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. |
Sensing output:Output operation | Switchable either Light-ON or Dark-ON |
Sensing output:Short-circuit protection | Incorporated |
Response time | 3 ms or less |
Operation indicator | Red LED (lights up when the output is ON) |
Stability indicator | Green LED (Light-ON mode: lights up under stable light received condition, Dark-ON mode: lights up under stable dark condition) |
Emitting indicator | Red LED (lights up during beam emission) |
Sensitivity adjuster | Continuously variable adjuster |
Protection | IP67 (IEC) |
Ambient temperature | -20 to +60 degrees -4 to +140 degrees Fahrenheit (No dew condensation or icing allowed), Storage: -30 to +70 degrees -22 to +158 degrees Fahrenheit |
Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
Ambient illuminance | Incandescent light: 3,500 Lx or less at the light-receiving face |
Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 500 Hz frequency, 1.5 mm 0.059 in double amplitude (10 G max.) in X, Y and Z directions for two hours each |
Shock resistance | 500 m/s2 acceleration (50 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (modulated) |
Emitting element:Peak emission wavelength | 880 nm 0.035 mil |
Material | Enclosure: Die-cast zinc alloy Indicator cover: Polyethersulphone Lens: Polycarbonate |
Cable | 0.15 mm2 2-core oil, heat and cold resistant cabtyre cable, 5 m 16.404 ft long |
Cable extension | - (Note) When extending the cable, the residual voltage will be increased depending on the type of cable used. Verify the residual voltage when extending the cable. |
Accessory | MS-RX-1 (Sensor mounting bracket): 1 set for emitter and receiver Adjusting screwdriver: 1 pc |
Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)