[System Maintenance Notice]
Due to ongoing system maintenance, the site search and specification search functions are temporarily unavailable. We apologize for any inconvenience this may cause and appreciate your understanding.

Search
Discontinued
Products


SD3-A1 | Safety Laser Scanner Type 3 SD3-A1(Discontinued)


Safety Laser Scanner Type 3 SD3-A1(Discontinued)

*Photo may vary from actual product.



  • Discontinued
  • Last time buyMarch 31, 2020
Product Number SD3-A1
Part Number SD3-A1
Product Safety Laser Scanner Type 3
Product name Safety Laser Scanner Type 3 SD3-A1(Discontinued)
  • Substitute -
  • Sub Prod No. -
  • Sub Part No. -
  • Remark Sorry, no suggested alternative products.

Spec Detail As of March 31, 2020

Item Specifications
Product Number SD3-A1
Part Number SD3-A1
Applicable standards:International standard IEC 61496-1/3 (Type 3), ISO 13849-1 (Category 3, PLd), IEC 61508-1 to 7 (SIL2), IEC 62061 (SIL2)
Applicable standards:Japan JIS B 9704-1/3 (Type 3), JIS B 9705-1 (Category 3), JIS C 0508 (SIL2)
Applicable standards:Europe EN 61496-1 (Type 3), ISO 13849-1 (Category 3, PLd), EN 61508-1 to 7 (SIL2)
dummy dia. 150 mm dia. 5.906 in/0 to 4.0 m 0 to 13.123 ft
dia. 70 mm dia. 2.756 in/0 to 4.0 m 0 to 13.123 ft
dia. 50 mm dia. 1.969 in/0 to 2.8 m 0 to 9.186 ft
dia. 40 mm dia. 1.575 in/0 to 2.2 m 0 to 7.218 ft
dia. 30 mm dia. 1.181 in/0 to 1.6 m 0 to 5.249 ft
dummy When dust suppression function is not selected: 83 mm 3.268 in
When dust suppression function is selected: 83 mm 3.268 in for less than 3.5 mm 0.138 in, and 100 mm 3.937 in for 3.5 mm 0.138 in or more
(automatically calculated using the included software)
dummy Minimum 1.8 %
dummy dia. 150 mm dia. 5.906 in (fixed)
dummy 0 to 15 m 0 to 49.213 ft
dummy Minimum 20 %
dummy 50 m 164.042 ft (fixed)
dummy 190degrees / 180degrees (by setting)
dummy Max. 7 + 1 (without detection zone)
[Zone pairs in combination of detection zone and warning zone can be switched over by external input]
dummy 200mm 7.874 in
dummy 24 V DC+20-30 % (IEC 60742)
Current consumption 300mA approx. (excluding external connection load)
Fuse rating 1.25 A semi-time-lag fuse
Control outputs (OSSD 1, OSSD 2) PNP open-collector transistor 2 outputs
- Rated operating voltage: supply voltage (UB) - 3.2 V
- Max. source current: 250 mA
- Residual voltage: 3.2 V or less
Control outputs (OSSD 1, OSSD 2):Operation mode When no object enters into the detection zone: ON
When an object enters: OFF
Control output(OSSD 1, OSSD 2):Response time Min. 80 ms (2 scans) to max. 640 ms (16 scans) switching method
Control outputs (OSSD 1, OSSD 2):Protection circuit Incorporated
dummy PNP open-collector transistor
- Rated operating voltage: supply voltage (UB) - 4 V
- Max. source current: 100 mA
- Residual voltage: 4 V or less
dummy Switching method of operation mode (set by below)
- Not used
- Main unit at normal operation: ON, Abnormal operation: OFF
- When no object enters into the warning zone: ON, When an object enters: OFF
- Main unit at normal operation: ON, Abnormal operation: OFF and When no object enters into the warning zone: ON, When an object enters: OFF
dummy Min. 80 ms (2 scans) to max. 640 ms (16 scans) switching method
dummy PNP open-collector transistor
- Rated operating voltage: supply voltage (UB) - 4 V
- Max. source current: 100 mA
- Residual voltage: 4 V or less
dummy Main unit at normal operation: ON
Abnormal operation: OFF
dummy Class 1 [IEC 60825, FDA (Note) ]
(Note) In accordance Laser Warning 50 (2007.6.24), based on FDA regulations (21 CFR 1040.10, 1040.11).
dummy 905 nm 0.036 mil
Environmental resistance:Degree of protection IP65
Environmental resistance:Ambient temperature 0 to +50degrees +32 to +122 degrees Fahrenheit , Storage: -20 to +60degrees -4 to +140 degrees Fahrenheit
Environmental resistance:Ambient humidity Operation and storage: Max. 95 % RH (No dew condensation)
dummy 10 to 150 Hz frequency, 5 G max. (50 m/s2 approx.) in X, Y and Z directions for twenty times each
Maximum cable length 15-pin plug: Max. 50 m 164.042 ft
9-pin plug: Max. 10 m 32.808 ft (when using RS-232C) / Max. 50 m 164.042 ft (when using RS-422)
(by using optional connection cable) (Note)
(Note) Be careful that a voltage drop may occur depending on the cable length or cable's conductor cross-section area.
Material Main body: Die-cast aluminum
Scanner window: Thermoplastic resin
Accessories SD3-PS (exclusive 15-pin connector): 1 pc
SD3-RS232 (exclusive 9-pin connector): 1 pc
Mounting screws [M5 (length 20 mm 0.787 in) hexagon-socket-head bolt: 2 pcs M5 (length 16 mm 0.630 in) hexagon-socket-head bolt: 2 pcs., attached to SD3-PS]: 1 set
Simplified instruction manual: 1 copy
Installation CD-ROM (includes detailed instruction manual data): 1 CD
Weight Net weight: 2.1 kg approx
Gross weight: 2.9 kg approx

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)