SF-C13 | Exclusive Control Unit for Safety Light Curtain SF-C10


Exclusive Control Unit for Safety Light Curtain SF-C10

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number SF-C13
Part Number SF-C13
Product Exclusive Control Unit for Safety Light Curtain
Details Slim type control unit
Product name Exclusive Control Unit for Safety Light Curtain SF-C10

As of April 20, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number SF-C13
Part Number SF-C13
Connectable safety light curtains Safety light curtains manufactured by our company
Applicable standards EN 61496-1 (Type 4), EN 55011, EN ISO 13849-1:2015 (Category 4, , PLe), IEC 61496-1 (Type 4), ISO 13849-1:2015 (Category 4, PLe), JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4), ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2)
Applicable regulations CE Marking (Machinery Directive, EMC Directive, RoHS Directive),UKCA Marking (Machinery Regulations, EMC Regulations, RoHS Regulations)
Power voltage 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption 100 mA or less (without safety light curtain)
Fuse rating Built-in electronic fuse, Triggering current: 0.5 A or more, Reset after power down
Enabling path NO contact × 3 (13-14, 23-24, 33-34)
Enabling path : Utilization AC-15, DC-13 (IEC 60947-5-1)
Enabling path : Rated operation voltage (Ue) / Rated operation current (le) 30 V DC / 4 A, 230 V AC / 4 A, resistive load(For inductive load, during contact protection)Min. applicable load: 10 mA (at 24 V DC)
(Note) : If several SF-C11 or SF-C13 units are being used in a line together, leave a space of 5 mm 0.197 in or more between each unit.
Enabling path : Contact material / contacts Silver tin oxide (AgSnO), self cleaning, positively driven
Enabling path : Contact resistance 100 mOhm or less (initial value)
Enabling path : Contact protection fuse rating 4 A (slow blow)
Enabling path : Mechanical lifetime 10,000,000 times or more (open/close frequency of 180 times/min)
(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Enabling path : Electrical lifetime 100,000 times or more (open/close frequency of 20 times/min, 230 V AC, 3 A, using resistance load)
(Note:The life expectancy of the relay varies depending on the type of load, open / close frequency, ambient conditions and others.)
Pick-up delay(Auto reset / Manual reset) 80 ms or less / 90 ms or less
Response time 10 ms or less
Auxiliary outputs Safety relay contact (NC contact) × 1 (41-42) (Related to enabling path)
Auxiliary output:Rated operation voltage / current 24 V DC / 2 A, Min. applicable load: 10 mA (at 24 V DC)
Auxiliary output:Contact protection fuse rated 2 A (slow blow)
Semiconductor auxiliary output(AUX) PNP open‑collector transistor
• Maximum source current: 60 mA
• Applied voltage: same as supply voltage (between the auxiliary output and +V)
• Residual voltage: 2.3 V or less (at 60 mA source current)
• Leakage current: 2 mA or less
Semiconductor auxiliary output(AUX):Output operation ON when the safety light curtain is interrupted
Excess voltage category II
Indicators:Power supply (Ui) Green LED (lights up when the power is ON)
Indicators : Enabling path (OUT) Green LED (lights up when the enabling contacts are closed)
Indicators:Interlock (INTER_LOCK) Yellow LED (lights up when enabling contacts are opened)
Indicators:Fault (FAULT) Yellow LED (blinks when fault occurs)
External relay monitor function Incorporated
Trailing edge function Incorporated
Polarity selection function Incorporated (Cable connection allows selection of plus/minus ground)
Minus ground: Correspond to PNP output safety light curtain
Plus ground: Correspond to NPN output safety light curtain
(Note):Please switch the sliding switch to the PNP side for minus ground and to the NPN side for plus ground.
Pollution degree 2
Environmental resistance:Degree of protection Enclosure: IP40
Terminal: IP20
Environmental resistance:Ambient temperature -10 to +55 ℃ +14 to +131
(No dew condensation or icing allowed),
Storage: -25 to +70 ℃ -13 to +158℉
Environmental resistance:Ambient humidity 30 to 85 % RH, Storage: 30 to 95 % RH
Environmental resistance:Vibration resistance Malfunction resistance 10 to 55Hz, 0.35 mm 0.014 in double amplitude 20 times each in X, Y, and Z directions
Enclosure material ABS
Connection terminal Spring-cage terminal
Weight Net weight: 200 g approx.

Return to top

Accessories (Option)

no_image
Product Number SFD-CC10
Part Number SFD-CC10
Product name Extension Cable
no_image
Product Number SFD-CC10-MU
Part Number SFD-CC10-MU
Product name Extension Cable
no_image
Product Number SFD-CC10-S
Part Number SFD-CC10-S
Product name Extension Cable


More



Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)