SG-C1-21-MM | Enable grip switch SG-C1


Enable grip switch SG-C1

*Photo may vary from actual product.

  • RoHS Compliant This product has been confirmed that it does not contain the 6 substances specified in EU RoHS Directive 2011/65/EU and the 4 substances specified in 2015/863/EU.  


Product Number SG-C1-21-MM
Part Number SG-C1-21-MM
Product Enable grip switch
Product name Enable grip switch SG-C1

As of May 18, 2024
Specifications and design of the products are subject to change without notice for the product improvement.

Spec Detail

Item Specifications
Product Number SG-C1-21-MM
Part Number SG-C1-21-MM
Contact configuration : 3 position enabling switch 2
contacts
Contact configuration : Push monitor switch With
(1NC)
Contact configuration : Additional control units : Emergency stop switch Without
Contact configuration : Additional control units : Control unit (A) Momentary pushbutton switch (2c)
Contact configuration : Additional control units : Control unit (B) Momentary pushbutton switch (2c)
Contact configuration : Additional control units : Indicator (green) (C) Without
Rubber boot material / Color Silicone rubber /
(Yellow)
(Note): Silicone rubber: Can be used in general factories. Remains flexible in cold temperatures. Suitable in applications with a wide operating temperature range.
Wiring style Solder terminal
Applicable standards IEC 60947-5-1, EN 60947-5-1, JIS C 8201-5-1, GS-ET-22, UL 508, CSA C22.2 No.14
Applicable standards : Standards for use ISO 12100 / EN ISO 12100, IEC 60204-1 / EN 60204-1, ISO 11161 / EN ISO11161, ISO 10218-1 / EN ISO 10218-1, ANSI/RIA/ISO 10218-1, ANSI/RIA R15.06, ANSI B11.19, ISO 13849-1: 2015 / EN ISO 13849-1: 2015
Applicable regulations CE Marking [Machinery Directive (2006/42/EC), RoSH Directive], UKCA Marking [Supply of Machinery (Safety) Regulations (2008 No.1597), RoSH Regulations]
Operating condition : Ambient temperature -25 to +60 ℃ -13 to +140 ℉ (No dew condensation or icing allowed)
Storage : -40 to +80 ℃ -40 to +176 ℉
Operating condition : Ambient humidity 45 to 85 % RH
Operating condition : Pollution degree 3 (Inside 2)
Operating condition : Altitude 2,000 m 6,561.68 ft max.
Impulse withstand voltage (Uimp) 2.5 kV (Momentary pushbutton switch and key selector switch : 1.5 kV)
Rated insulation voltage (Ui) 250 V (Momentary pushbutton switch and key selector switch : 125 V) /
Models with indicator : 30 V
Thermal current (Ith) 3 A (Emergency stop switch : 5 A)
Rated operational voltage (Ue) / Rated operational current (Ie)
  Ue
  30V 125V 250V
Ie Grip switch 3 position enabling switch
(Terminal No.: NO1-C1, NO2-C2)
AC Resistive load (AC-12) - 1A 0.5A
Inductive load (ACー15) - 0.7A 0.5A
DC Resistive load (DC-12) 1A 0.2A -
Inductive load (DC-13) 0.7A 0.1A -
Push monitor switch
(Terminal No. 31-32)
AC Resistive load (AC-12) - 2.5A 1.5A
Inductive load (ACー15) - 1.5A 0.75A
DC Resistive load (DC-12) 2.5A 1.1A 0.55A
Inductive load (DC-13) 2.3A 0.55A 0.27A
Emergency stop switch
(Terminal No. 1-2, 1-2)
AC Resistive load (AC-12) - 5A 3A
Inductive load (ACー15) - 3A 1.5A
DC Resistive load (DC-12) 2A 0.4A 0.2A
Inductive load (DC-13) 1A 0.22A 0.1A
Momentary pushbutton switch
/ Key selector switch
(Terminal No.C1-NO1, NC1
C2-NO2, NC2 )
AC Resistive load (AC-12) - 0.5A -
Inductive load (ACー15) - 0.3A -
DC Resistive load (DC-12) 1A 0.2A -
Inductive load (DC-13) 0.7A 0.1A -
Electric shock protection class Class II (IEC 61140), 回(double insulated)
(Models with indicator : Class III)
Operating frequency 1,200 operations/hour
B10D 2,000,000
(ISO 13849-1 Annex C Table C.1)
Mechanical durability Position 1→2→1 : 1,000,000 operations min.
Position 1→2→3→1 : 100,000 operations min.
Electrical durability 100,000 operations min. (Rated operating load)
1,000,000 operations min. (AC / DC 24 V 100 mA)
Shock resistance Malfunction : 150 m/s2, Destruction : 1,000 m/s2
Free fall 1.0 m 3.281 ft 1 time (Based on IEC60068-2-32)
Vibration resistance Malfunction : 5 to 55 Hz, half amplitude 0.5 mm 0.020 in
Destruction : 16.7 Hz, half amplitude 1.5 mm 0.059 in
Conditional short-circuit current 50 A (250 V)
Short-circuit protective device 250 V AC, 10 A Fuse (IEC60127-1)
Direct opening force 60 N min. (Push monitor switch)
Direct opening travel 4.7 mm 0.185 in min. (Push monitor switch)
Actuator Strength (Entire button is pushed) 500 N min. (Grip switch)
Indicator Green LED
Rated Operating Voltage : DC 24 V ±10 %
Rated current : 15 mA
(Note): As for the type with pilot light, Ue (contact ratings) of all switches is only less than 30 V DC, and connect all switches to SELV (safety extra low voltage) or PELV (protective extra low voltage) circuit.
Weight Approx. 155 g

Return to top

CONTACT US
If you have any questions, please select the option below to contact us or find answers.
CONTACT BY EMAIL / PHONE FIND LOCAL OFFICE

Return to top

CONTACT US
BY EMAIL
Please click your area to select country or region



Requests to customers (Automation Control Components & Industrial Device) [Excluding specific product]
Requests to customers (Automation Control Components & Industrial Device) [For specific product]
Requests to customers (FA Sensors & Components [Excluding motors])
Requests to customers (Dedicated to industrial motors)